• 제목/요약/키워드: Double line

검색결과 774건 처리시간 0.031초

병행 2회선 송전선로에서의 고장점 표정 알고리즘 (A Fault Location Algorithm of a Double-Circuit Line)

  • 안용진;최면송;강상희;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.255-257
    • /
    • 1999
  • Fault location algorithms based on the current distribution factors under the one-phase to earth fault condition of a double-circuit line are presented. The derivation method for current distribution factors is showed, to calculate fault current, fault resistance and the zero sequence current of other parallel circuit which are unknown. As the proposed algorithms 1,2,3 embodies an accurate location by the voltage and the current of the relaying point.

  • PDF

광역철도 좌석형급행열차 도입 타당성에 관한 연구 - 경춘선 복선화구간 중심으로 - (A Feasibility Investigation of adoption for the Seat-type Express Electric railway on the Railroad in Metropolitan area - Focus on the double tracked Seoul-Chuncheon line -)

  • 박민규;김시곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1447-1457
    • /
    • 2008
  • The operation of the Seat-type Express Electric railway (SEE) has been watched for an alternative plan according to the increase of competition among the vehicle in metropolitan city. The purpose of this study was to examine a feasibility for the adoption of the SEE by analysis of various condition in the double tracked Souel-Chuncheon line. Fare estimate, station selection for SEE, managerial plan, demanding forecasting and analysis were performed to compute financial efficiency. The results showed financial validity on Revenue Cost Ratio (R/C), Financial Net Present Value (FNPV), Financial Internal Rate of Return (FIRR). This results indicate the evidence that SEE is a new means which is able to complement for finance, transportation capacity in metropolitan city.

  • PDF

2회선 배전계통에서 가공지선 접지 및 피뢰기 설치환경에 따른 뇌과전압 해석 (Analysis of Lightning Overvoltage with Earth of Overhead Grounding Wire and Installation Types of Arrester in Double Circuits Distribution Systems)

  • 정채균;김상국;이종범;정영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.497-499
    • /
    • 2003
  • This paper analyses the lightning overvoltage with earth of grounding wire and installation types of arresters in double circuits distribution systems. First, the model for analysis is selected severer case between upper line and lower line when the direct lightning surge strikes on the overhead grounding wire. The lightning overvoltage is variously calculated with earth distance between overhead grounding wires. This paper also analyses the effect of the installation distance between arrestors and the earth resistance of overhead grounding wire. From these results, authors examine the rationality of BIL that is applied in distribution system.

  • PDF

리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘 (A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems)

  • 안용진;강상희;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF

Video Palmprint Recognition System Based on Modified Double-line-single-point Assisted Placement

  • Wu, Tengfei;Leng, Lu
    • Journal of Multimedia Information System
    • /
    • 제8권1호
    • /
    • pp.23-30
    • /
    • 2021
  • Palmprint has become a popular biometric modality; however, palmprint recognition has not been conducted in video media. Video palmprint recognition (VPR) has some advantages that are absent in image palmprint recognition. In VPR, the registration and recognition can be automatically implemented without users' manual manipulation. A good-quality image can be selected from the video frames or generated from the fusion of multiple video frames. VPR in contactless mode overcomes several problems caused by contact mode; however, contactless mode, especially mobile mode, encounters with several revere challenges. Double-line-single-point (DLSP) assisted placement technique can overcome the challenges as well as effectively reduce the localization error and computation complexity. This paper modifies DLSP technique to reduce the invalid area in the frames. In addition, the valid frames, in which users place their hands correctly, are selected according to finger gap judgement, and then some key frames, which have good quality, are selected from the valid frames as the gallery samples that are matched with the query samples for authentication decision. The VPR algorithm is conducted on the system designed and developed on mobile device.

Connection between a Small-Scale Emerging Island and Double Arc Loops Producing a M6.5 Flare in Active Region 12371

  • Kang, Jihye;Inoue, Satoshi;Moon, Yong-Jae;Magara, Tetsuya;Kusano, Kanya
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.81.3-81.3
    • /
    • 2017
  • In this paper, we report a small-scale emerging island and double arc loops, which are associated with a M6.5 flare, in Active Region 12371. We investigate the spatial and temporal changes of both photospheric magnetic fields using SDO/HMI data and coronal magnetic structures obtained from nonliner force-free field (NLFFF) extrapolation. From the vector magnetograms, we find a small-scale emerging island near the main polarityy inversion line about three hours before the flare. The island has a strong shear angle, which is determined by difference between transverse component of observed field and potential field, of around 90 degrees. Furthermore, the NLFFF well reproduces a sigmoidal structure seen in SDO/AIA 94, which is consistent with the double arc loops configuration suggested by Ishiguro and Kusano (2017) who introduced a magnetic configuration showing the double arc instability. The observed emerging island is located among the double arc loops, which is also supproted by their model. Finally, there was an eruption (M6.5 flare) associated with the loops. We discuss a possible role of the double arc instability for the eruption.

  • PDF

이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구 (A research on the design parameters for a double-transmission main system for sustainable water supply)

  • 현인환;홍준의;김두일
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

염가형 고성능 단상 UPS 개발 (Development of Single Phase UPS for Low Cost and High Performance)

  • 임승범;이윤하;지준근;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.199-200
    • /
    • 2011
  • Uninterruptible Power Supply(UPS) is largely divided into passive-standby, line-interactive and double-conversion methods. This paper proposes the double-conversion UPS for low cost and high performance. The proposed UPS are composed of PFC, inverter, battery charger and discharger. Finally, the validity of proposed UPS was verified by experiments.

  • PDF

빠른 항성풍 거품의 구각형성 시각과 [OIII]선의 형성 (THIN SHELL FORMATION TIME AND [OIII] LINE IN FAST WIND BUBBLE)

  • 최승언;이영진
    • 천문학논총
    • /
    • 제11권1호
    • /
    • pp.91-107
    • /
    • 1996
  • We determine analytically the onset of thin-shell formation time of fast wind bubble with power-law energy injection $E_{in}=E_0t^s$, and power-law ambient density structure, ${\rho}_0(r)={\bar{\rho}}(r/{\bar{r}})^{-{\omega}}$. Thin-shell formation time, $t_{sf}$ can be estimated by minimizing the total time elapsed before the complete cooling of shocked gas. For uniform medium (${\omega}=0$) and constant energy injection (s = 1), the onset of shell formation is found to be at $t_{sf}=5.2{\times}10^3yr$, which agrees Quite well with the results of FCT 1D numerical calculation. We solve the line transfer problem with previous result derived by numerical calculation in order to calculate line profile of [OIII] (${\lambda}=5007{\AA}$) forbidden line. In general, radiative outer shell causes the formation of double peaked line profile. Each peak corresponds to approaching and receeding shells with large velocities. Our line profiles show good agreements with observation of expanding shell structure.

  • PDF

공통 결함접지구조를 이용한 링 하이브리드 커플러의 소형화 설계 (Design of Size-reduced Ring Hybrid Couplers Using a Common Defected Ground Structure)

  • 임종식;이준;권경훈;정용채;한상민;안달
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1662-1667
    • /
    • 2012
  • This paper describes the design of size-reduced ring hybrid couplers (RHC) using a common defected ground structure (CDGS). The proposed RHC consists of double-sided microstrip line and the CDGS patterns which are placed in the common ground plane of the double-sided microstrip line. The effects of DGS as a periodic structure are imposed on both microstrip lines, so the advantages of the existing DGS are doubled. The normal RHC is designed first and folded by the half reference plane with the CDGS realized on the common ground plane. So another trial for size-reduction is performed by folding the RHC and inserting CDGS besides to the conventional DGS. In order to show a design example, a 2GHz RHC is designed and miniaturized using CDGS. The size of the miniaturized RHS is around 50% of the normal one, while the performances are well preserved even after the size-reduction.