• Title/Summary/Keyword: Double gap

Search Result 301, Processing Time 0.028 seconds

Growth and photocurrent study on the splitting of the valence band for ZnIn2S4 single crystal thin film by hot wall epitaxy (Hot Wall Epitaxy (HWE)법에 의한 ZnIn2S4 단결정 박막 성장과 가전자대 갈라짐에 대한 광전류 연구)

  • Hong, Kwang-Joon
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.419-427
    • /
    • 2007
  • Single crystal $ZnIn_{2}S_{4}$ layers were grown on a thoroughly etched semi-insulating GaAs(100) substrate at $450^{\circ}C$ with the hot wall epitaxy (HWE) system by evaporating the polycrystal source of $ZnIn_{2}S_{4}$ at $610^{\circ}C$ prepared from horizontal electric furnace. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of single crystal $ZnIn_{2}S_{4}$ thin films measured with Hall effect by van der Pauw method are $8.51{\times}10^{17}\;electron/cm^{-3}$, $291{\;}cm^{2}/v-s$ at 293 K, respectively. The photocurrent and the absorption spectra of $ZnIn_{2}S_{4}$/SI(Semi-Insulated) GaAs(100) are measured ranging from 293 K to 10 K. The temperature dependence of the energy band gap of the $ZnIn_{2}S_{4}$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)$=2.9514 eV. ($7.24{\times}10^{-4}\;eV/K$)$T^{2}$/(T+489 K). Using the photocurrent spectra and the Hopfield quasicubic model, the crystal field energy(${\Delta}cr$) and the spin-orbit splitting energy(${\Delta}so$) for the valence band of the $ZnIn_{2}S_{4}$ have been estimated to be 167.8 meV and 14.8 meV at 10 K, respectively. The three photocurrent peaks observed at 10 K are ascribed to the $A_{1}$-, $B_{1}$-, and $C_{41}$-exciton peaks.

How can we narrow the digital divide among SMEs in APEC member economies? (중소기업 정보화 수준 격차 해소방안에 관한 국가 간 비교연구)

  • Kwon, Sun-Dong;Yang, Hee-Dong;Sohn, Yong-Yeop;Lee, Seong-Bong;Sirh, Jin-Young;Cho, Taek-Hee
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.2
    • /
    • pp.79-106
    • /
    • 2005
  • This study, by adopting case study methodology, is focused on examining the present state and analyzing the cause of the digital divide, and suggesting policies for bridging the divide, specifically in view of SMEs. We have taken cases of manufacturing companies, visiting and interviewing 18 SMEs in 10 APEC member economies which show sharp difference in usage of ICT. In order to analyze the digital gap among SMEs, we used 5 variables that are composed of computer hardware, computer software, Internet, readiness of ICT, and performance of ICT adoption, while categorizing the cases into low and high tier based on the national ICT index. From a computer hardware perspective, the high tier (0.66) has almost double the number of PC’s per employee, compared with the low tiers (0.34). This gap can be explained by financial availability of low income and high tariff in the developing economies. In the computer software perspective, the SMEs in the low tier had some restrictive use of computer applications such as financial and accounting management and document management, while those in the high tier enjoyed more diversity in the use of applications such as inventory management, sales management, financial and accounting management, procurement management, CRM, and ERP. In view of the readiness of ICT, the difference in ICT infrastructure and financial status between the low and high tier was far wider than any other variables. As a result of ICT adoption, SMEs benefited in view of learning and growth, internal business processes, customer service, and financial affairs. To effectively bridge the digital divide between the low and high tier, actions such as setting up a secondary market of used computers among cooperating developed and developing countries, developing and diffusing good business applications, and building speedy, low-cost telecommunication infrastructures should be taken.

  • PDF

Temperature dependence of photocurrent spectra for $AgGaSe_2$ single crystal thin film grown by hot wall epitaxy (Hot Wall Epitaxy(HWE) 법에 의해 성장된 $AgGaSe_2$ 단결정 박막의 광전류 온도 의존성)

  • Hong, Kwang-Joon;Bang, Jin-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.179-180
    • /
    • 2007
  • Single crystal $AgGaSe_2$ layers were grown on thoroughly etched semi-insulating GaAs(100) substrate at $420^{\circ}C$ with hot wall epitaxy (HWE) system by evaporating $AgGaSe_2$ source at $630^{\circ}C$. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of single crystal $AgGaSe_2$ thin films measured with Hall effect by van der Pauw method are $4.05{\times}\;10^{16}/cm^3$, $139\;cm^2/V{\cdot}s$ at 293 K. respectively. The temperature dependence of the energy band gap of the $AgGaSe_2$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=1.9501\;eV\;-\;(8.79{\times}10^{-4}\;eV/K)T^2$/(T + 250 K). The crystal field and the spin-orbit splitting energies for the valence band of the $AgGaSe_2$ have been estimated to be 0.3132 eV and 0.3725 eV at 10 K, respectively, by means of the phcitocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}So$ definitely exists in the $\Gamma_5$ states of the valence band of the $AgGaSe_2$. The three photocurrent peaks observed at 10 K are ascribed to the $A_1$-, $B_1$-, and $C_1$-exciton peaks for n = 1.

  • PDF

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

A Study on Cooling Effect and Power Control of a Mini Ozonizer (소형 오존발생장치의 전력제어와 냉각효과에 관한 연구)

  • Woo, Sung-Hoon;Park, Seung-Cho;Yoon, Sung-Yoon;Park, Jee-Ho;Woo, Jung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • In this paper, a control method of a mini ozone generator is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2^{\circ}C$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the transient responses with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.

The effect of impact with adjacent structure on seismic behavior of base-isolated buildings with DCFP bearings

  • Bagheri, Morteza;Khoshnoudiana, Faramarz
    • Structural Engineering and Mechanics
    • /
    • v.51 no.2
    • /
    • pp.277-297
    • /
    • 2014
  • Since the isolation bearings undergo large displacements in base-isolated structures, impact with adjacent structures is inevitable. Therefore, in this investigation, the effect of impact on seismic response of isolated structures mounted on double concave friction pendulum (DCFP) bearings subjected to near field ground motions is considered. A non-linear viscoelastic model of collision is used to simulate structural pounding more accurately. 2-, 4- and 8-story base-isolated buildings adjacent to fixed-base structures are modeled and the coupled differential equations of motion related to these isolated systems are solved in the MATLAB environment using the SIMULINK toolbox. The variation of seismic responses such as base shear, displacement in the isolation system and superstructure (top floor) is computed to study the impact condition. Also, the effects of variation of system parameters: isolation period, superstructure period, size of seismic gap between two structures, radius of curvature of the sliding surface and friction coefficient of isolator are contemplated in this study. It is concluded that the normalized base shear, bearing and top floor displacement increase due to impact with adjacent structure. When the distance between two structures decreases, the base shear and displacement increase comparing to no impact condition. Besides, the increase in friction coefficient difference also causes the normalized base shear and displacement in isolation system and superstructure increase in comparison with bi-linear hysteretic behavior of base isolation system. Totally, the comparison of results indicates that the changes in values of friction coefficient have more significant effects on 2-story building than 4- and 8-story buildings.

Reconstruction of Neglected Achilles Tendon Rupture with Flexor Hallucis Longus Augmentation Using One Incision Technique (진구성 아킬레스 건 파열에 대한 단일 절개 술식을 통한 건이전술 및 재건술)

  • Park, Kwang-Hwan;Kim, Bom-Soo;Lee, Jin-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the clinical outcome of neglected Achilles tendon rupture treated with reconstruction and augmentation with flexor hallucis longus (FHL) tendon using one incision technique. Materials and Methods: Between July 2006 and March 2008, eleven patients with neglected Achilles tendon rupture received surgical treatment. Through one incision technique, augmentation with auto FHL tendon transfer was performed using a Bio-Interference screw (Arthrex, Naples, FL) and followed by V-Y advancement (5 cases) or gastronemius fascial turn-down flap procedure (6 cases). After mean follow up of 20.7 months (range, 11.8-33.3 weeks), clinical outcomes were evaluated with Visual Analogue Scale (VAS), American Orthopedic Foot and Ankle Society (AOFAS) score, 10 repetitive double heel raise test, 10 repetitive single heel raise test and subjective satisfaction. Results: The length of the gap after debridement was $5.4{\pm}2.0$ cm. The VAS improved from $4.1{\pm}0.9$ to $1.5{\pm}0.8$ at last follow up (p<0.05). The AOFAS score increased from $38.9{\pm}12.2$ to $91.5{\pm}8.9$ at last follow up (p<0.05). Eight patients were satisfied with excellent results and three were satisfied with good results. All patients were able to perform 10 repetitive double heel raise and nine out of eleven patients were able to perform 10 repetitive single heel raise at last follow up. There were no complications including deep infection or re-rupture. Conclusion: Augmentation with FHL tendon transfer and reconstruction with V-Y advancement or turn-down flap through one incision technique appeared to be effective and safe. This technique is recommendable for the treatment of neglected Achilles tendon rupture.

  • PDF

Design and Trend Analysis According to the Application Field of Monopole Antenna with Sleeve Structure (슬리브 구조를 갖는 모노폴 안테나의 활용분야에 따른 설계와 동향분석)

  • Kang, Sang-Won;Byeon, Mi-Kyeong;Lee, Shin-Hee;Choe, Gwang-Je
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.135-141
    • /
    • 2020
  • This paper summarizes the data of a monopole antenna with a sleeve structure that can be applied in various ways. Sleeve monopole antennas have broadband characteristics and are used for multi-frequency applications. The sleeve monopole antenna is composed of a vertical conductor, which is a radiator, and a sleeve having the same structure as a coaxial cable. The sleeve acts as a radiator and an open stub. The length of the sleeve should be 1/3~2/3 of the total length of the antenna. A monopole antenna having a sleeve structure is applicable to a vehicle wiper antenna. In addition, the case of applying this antenna to a broadband sleeve antenna using a loading coil, a broadband printed sleeve monopole antenna for an ISM band, a gap sleeve and a double sleeve, and a UWB planar monopole antenna using half cutting was summarized and analyzed in terms of structure and broadband.

Uptake Effects of Two Electrons for Relative Stability and Atomic Structures of Carbon Cluster Isomers of C20: ab initio Methods

  • Lee, Wang-Ro;Lee, Chang-Hoon;Kang, Jin-Hee;Park, Sung-Soo;Hwang, Yong-Gyoo;Lee, Kee-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.445-448
    • /
    • 2009
  • This study examined the effect of the uptake of one and two electrons on the atomic structure of three isomers of $C_{20}$ clusters, namely the ring, bowl (corannulene like), and cage (the smallest fullerene). Geometry optimizations were performed using the hybrid density functional (B3LYP) methods for neutral, singly and doubly charged $C_{20},\;{C_{20}}^-,and\;{C_{20}}^{2-}$. These results show that the symmetry of the lowest energies for ring and bowl isomers were not changed, whereas the increasing order of energy for the cage (the smallest fullerene) isomers was changed from $D_{2h}\;<\;C_{2h}\;{\leq}\;C_2\;of\;C_{20}\;through\;Ci\;<\;C_{2h}\;<\;C_2\;<\;D_{2h}\;of\;{C_{20}}^-\;to\;Ci\;<\;C_2\;<\;D_{2h}\;<\;C_{2h}\;of\;{C_{20}}^{2-}$. The reduced symmetry isomers of the cage have comparative energy and the ground state symmetry of the neutral and single and double charged $C_{20}$ decreased with increasing number of electrons taken up in the point of energetics. Interestingly, the difference in energy between the ground state and the next higher energy state of ${C_{20}}^{2-}$ was 3.5kcal/mol, which is the largest energy gap of the neutral, single anion and double anion of the cage isomers examined.

Dielectric Properties of K(Ta0.6Nb0.4)O3 Thin Films Prepared by Sol-Gel Method for Microwave Applications (마이크로웨이브 응용을 위한 솔-젤법으로 제작한 K(Ta0.6Nb0.4)O3 박막의 유전 특성)

  • Kwon, Min-Su;Lee, Sung-Gap;Kim, Kyeong-Min;Lee, Sam-Haeng;Kim, Young-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.403-407
    • /
    • 2018
  • In this study, double layer KTN/STO thin films were fabricated on $Pt/Ti/SiO_2/Si$ substrate, their structural and electrical properties were measured according with the number of STO coatings, and their applicability to microwave materials was investigated. The average grain size was about 80~90 nm, the average thickness of the 6-coated KTN thin film was about 320 nm, and the average thickness of the STO thin film coated once was about 45~50 nm. The dielectric constant decreased with increasing frequency, and as the number of STO coatings increased, the rate of change of the dielectric constant with the applied electric field decreased. The tunability of the KTN thin film showed a maximum value of 19.8% at 3 V. The figure of merit of the KTN/1STO thin film was 9.8 at 3 V.