• Title/Summary/Keyword: Double converter

Search Result 226, Processing Time 0.027 seconds

High voltage pulse power supply using thyratron (Thyratron을 이용한 고압펄스 발생장치)

  • Kim, T.J.;Kim, S.C.;Kim, E.S.;Baek, J.W.;Pavlov, E.P.;Lee, H.S.;Jeon, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2127-2129
    • /
    • 1998
  • In this paper, discharging part of high voltage pulse power supply of E-beam generating device is simulated and experimented. It is composed of high voltage part and high voltage pulse part. High voltage part is AC 380, DC/DC converter, high voltage high frequency transformer. High voltage pulse part is double pulse forming network and Thyratron. In the result, computer simulation analysis is same to experimental result and high voltage pulse is obtained 10kV, 4A, 10uS.

  • PDF

A Control Method of Electric Railway Vehicle Recycle Energy Storage System Using Supercapacitor (슈퍼커패시터를 이용한 전동차량 화생 에너지 저장 시스템의 제어기법)

  • Noh, Se-Jin;Lee, Jin-Mok;Son, Kyoung-Min;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.97-99
    • /
    • 2008
  • It is possible to suppress voltage drops, power loading fluctuations and regeneration power lapses for DC railway systems by applying an energy storage system. Recently the electric double layer capacitor (EDLC) of the rapid charge/discharge type has been developed and used in wide ranges. The on board energy storage system with supercapacitor for railway vehicles presented in this paper seems to be a reliable technical solution with an enormous energy saving potential. In this paper, an efficient charge and discharge control method of a bidirectional DC-DC converter using the supercapacitor is proposed.

  • PDF

Development of Dynamic Voltage Restorer System Considering Characteristics of EDLC (EDLC의 특성을 고려한 동적전압보상시스템의 개발)

  • Lee, Sang-Cheol;Seo, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.288-292
    • /
    • 2010
  • Recently, in energy storage system, the EDLC is paid attention as a new environmentally friendly energy storage element. This capacitor has higher energy density than the electrolytic capacitor. Also, this capacitor has a lot of advantage such as no maintenance, longer life cycle and faster charge-discharge time than the battery system. But the EDLC must have a each charge-discharge controller to effectively control, an energy design method circuit to use effectively energy, and several compensation techniques to control a optimal operating. In this respect, this study suggests major parameters to effectively represent the characteristics of EDLC, the measurement methods of those parameters have been investigated with experiments, and the interpretation about the buck/boost DC/DC converter for the operation of EDLC.

New Active Snubber Cells for High Step-up Interleaved DC-DC Converters

  • ;Kim, Seon-Ju;;Jeong, Hyeon-Ju;Choe, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.18-20
    • /
    • 2018
  • This paper proposes a new pair of Active Snubber Cells (ASCs) which can fully provide soft switching for a Floating-output Double Boost Converter (FDBC). Besides that, the introduced ASCs are applicable for all basic DC-DC converters. Main switches of the FDBC turn on and off with ZVS. However, the main diodes are ZCS turned off. Furthermore Snubber switches are turned on and off with ZCS and ZVS respectively. It worthy to mention also that the soft switching for snubber diodes of the presented cells is achieved. A 1.5kW, 100kHz prototype of the FDBC with the proposed ASCs was built and evaluated; and the maximum attained efficiency is 97.3%.

  • PDF

Active-Clamp Forward Converter with Double-Ended Rectifier Reducing DC offset Current in Transformer (낮은 변압기 오프셋 전류를 가지는 더블 앤디드 엑티브 클램프 포워드 컨버터)

  • Kim, Myung-Ho;Kim, Jae-kuk
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.15-17
    • /
    • 2018
  • 엑티브 클램프 포워드 컨버터는 고효율, 간단한 구조의 특징으로 PC 파워 시스템, 서버 파워 시스템과 같은 어플리케이션에 많이 사용 되고 있다. 특히 더블 앤디드 엑티브 클램프 포워드 컨버터는 작은 출력 필터와 고효율의 장점이 있으나, 변압기 오프셋 전류로 인해 변압기의 크기와 코어 손실이 증가하게 된다. 본 논문에서는 새로운 게이트 신호 조정을 통해 낮은 변압기 오프셋 전류를 갖는 새로운 더블 앤디드 엑티브 클램프 포워드 컨버터를 제안한다. 따라서 변압기의 크기와 코어 손실, 1차측과 출력 인덕터의 전력손실이 감소함으로써 높은 전력밀도와 고효율을 달성하게 된다.

  • PDF

Design of In-Wheel Type Switched Reluctance Motor for Electric Vehicle Traction and Wireless Charging (전기자동차 트랙션 및 무선 충전용 인휠타입 스위치드 릴럭턴스 전동기 설계)

  • Lukman, Grace Firsta;Son, Dong-Ho;Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1866-1872
    • /
    • 2017
  • This paper presents the design of in-wheel type Switched Reluctance Motor (SRM) which can be used as both traction motor and power pickup device in a wireless charging system of electric vehicles. The SRM acts as a traction drive in driving mode and a power receiver in charging mode to avoid any additional weights. Double stator axial field SRM is used due to its structure that can be mounted inside the wheel. The charging circuit is integrated with the asymmetric converter and phase windings of SRM, reducing the cost and size of the system. Magnetic resonance is implemented to increase the efficiency. Simulations done in Maxwell and Simplorer verify the effectiveness of the proposed system.

Two-phase Double Step-down DC-DC Converter Using Coupled Inductor (결합 인덕터를 이용한 2상 이중 강압형 직류-직류 컨버터)

  • Jeong, Seongyong;Cha, Honnyong;Kim, Heung-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.159-160
    • /
    • 2014
  • 기존 인터리브드 방식의 2상 이중 강압형 직류-직류 컨버터는 비절연 강압형 직류-직류 컨버터로 출력 전류 리플 감소, 이중 강압으로 인한 스위치 전압 스트레스 감소, 인덕터 전류 불평형 문제 해결, 그리고 스위칭 손실 감소 등의 장점으로 대용량 직류-직류 컨버터에 적합하다. 본 논문에서는 기존의 2상 이중 강압형 직류-직류 컨버터에 결합 인덕터를 적용하여 인덕터의 전류 리플을 감소시키고 이를 수치적으로 해석한다. 또한 결합 인덕터의 문제점인 각 상의 인덕터 전류 불평형으로 인한 인덕터 포화현상에 대하여 실험을 통해 확인 한다.

  • PDF

A Study on Double Converter for Urban Transit Power Supply (도시철도 전력공급용 더블컨버터에 관한 연구)

  • Jang, Choon-Seok;Kim, Sung-An;Kim, Hwan-Jin;Han, Gap-Jin;Cho, Yun-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.223-224
    • /
    • 2015
  • 도시철도에서 사용하는 전력공급 장치는 대부분 다이오드를 이용하여 전차선(DC)에 공급하고 있으며, 다이오드 특성상 단방향 전력공급이 가능하기 때문에 전동차의 회생제동으로 발생하는 회생 전력을 재사용 할 수 없는 단점을 가지고 있다. 따라서 본 논문에서는 전동차에서 발생하는 회생전력을 교류 모선으로 환원시켜주기 위하여 사이리스터를 이용한 양방향 더블컨버터를 제안한다. 더블컨버터의 제어 목적은 전차선의 부하에 따라 전압을 일정하게 유지시키면서 부하 조건에 따라 안정적인 모드 전환을 하는 것이다. 이를 위하여 더블컨버터의 병렬로 운전을 통하여 순차적인 모드 전환을 위한 알고리즘을 더블컨버터 시뮬레이션을 적용하여 검증하였다.

  • PDF

Analysis of Neutral Point Current in Grid Tied 3-level NPC Converter under Various Grid Imbalance Conditions (다양한 계통 불평형 상황에서 계통연계형 3-level NPC 컨버터의 중성점 전류에 대한 해석)

  • Choi, Jaehoon;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.186-188
    • /
    • 2019
  • 현재 신재생에너지 발전원은 계속 증가되고 있으며, 발전기의 용량 또한 점점 증가하고 있다. 늘어나는 신재생에너지 발전원에 의해 계통 연계의 중요성이 증대되고 있고 아울러 계통에서 발생할 수 있는 여러 가지 사고로 인한 발전기의 PCS의 고장에 대한 문제 또한 중요해지고 있다. 본 논문에서는 신재생발전원의 용량이 증가함에 따라서 각 스위치의 전기적 스트레스를 줄일 수 있는 3-level NPC 타입의 컨버터회로를 기반으로 이중 전류 제어기를 이용하였고, 계통 사고시에도 강인한 위상 추종 특성을 가지는 DDSRF(Decoupled Double Synchronous Reference Frame 이하 DDSRF)방식의 PPL을 채택하여 시뮬레이션을 진행하였다. 현재 계통의 사고에 의한 사고전압은 ABC 분류에 의해서 크게 A~G 타입으로 나타내고 있다. 본 논문에서는 각 타입별 사고전압의 불평형 지수(Imbalance Factor, 이하 IF)에 따른 중성점 전류의 고조파 성분을 분석하여 도식화 하고자 한다. 이는 계통사고 발생 시 계통연계형 컨버터의 제어 및 계통탈락 여부에 활용 할 수 있을 것으로 예상된다.

  • PDF

A Study on Optimal Design of Capacitance for Active Power Decoupling Circuits (능동 전력 디커플링 회로의 커패시턴스 최적 설계에 관한 연구)

  • Baek, Ki-Ho;Park, Sung-Min;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.181-190
    • /
    • 2019
  • Active power decoupling circuits have emerged to eliminate the inherent second-order ripple power in a single-phase power conversion system. This study proposes a design method to determine the optimal capacitance for active power decoupling circuits to achieve high power density. Minimum capacitance is derived by analyzing ripple power in a passive power decoupling circuit, a buck-type circuit, and a capacitor-split-type circuit. Double-frequency ripple power decoupling capabilities are also analyzed in three decoupling circuits under a 3.3 kW load condition for a battery charger application. To verify the proposed design method, the performance of the three decoupling circuits with the derived minimum capacitance is compared and analyzed through the results of MATLAB -Simulink and hardware-in-the-loop simulations.