• Title/Summary/Keyword: Double angle

Search Result 482, Processing Time 0.031 seconds

The Kinematic Analysis about Double Poling Technique of National Cross-Country Skiers at Start & Finish Phases (국가대표 크로스컨트리 스키 선수들의 Start & Finish 구간에 대한 Double poling 기술의 운동학적 분석)

  • Choi, Seul-Bi;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.95-104
    • /
    • 2012
  • The purpose of this study targeted to national cross-country skiers representatives was to implement hypothetical experiment on their patterns of the movements and analysis on kinematic variables occurred while double polling was conducted between starting and finishing phase of 56 meters. Furthermore, it aimed to provide a set of quantitative data to illustrate how to improve one's skill and performance of sprint. In our experiments, we conducted 3-dimension analysis of cycle characteristics, joint angle(hip, knee and elbow), and pole angle. The results showed that at the starting phase, the players did not show a significant difference in attributes of time and distance. In heat 1 where elbow angle and polling starts, the pole angle was noticeably high in heat 1. At the finishing phase, there was a considerable distinction with a high frequency in performing a short polling time and high speed in heat 3. The players showed large extension between the flexion and of the hip angle which indicates high contribution given from the movement of lower body(hip, knee).

Analysis of Patellar Tracking and Q-angle During Semi-Squat Exercises (반 쪼그려 앉기(Semi-Squat) 운동 시 무릎뼈 주행(Tracking)과 Q-각도 분석)

  • Park, Seung-Kyu;Yang, Dae-Jung;Park, Jae-Man;Han, Song-E
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • Closed kinematic chain exercises such as squatting have been widely indicated for knee rehabilitation in patients with patellofemoral disorders such as osteoarthritis and patellofemoral pain. Patellofemoral disorders are thought to be associated with abnormal patellar kinematics. In addition, the Q-angle may be undervalued in patients with patellofemoral pain and a laterally displaced patella. The purpose of this study was to assess patellar kinematics and the Q-angle during double-leg semi-squat and wall-slide semi-squat exercises. In this study, 28 asymptomatic subjects(16 male, 12 female) were assessed. Patellar tilt, patellar spin, and Q-angle were recorded using a motion analysis system during double-leg semi-squat and wall-slide semi-squat exercises. The Q-angle and patellar tilt were significantly increased, whereas patellar spin was significantly decreased, at $45^{\circ}$ of knee flexion compared with $0^{\circ}$. No differences were observed for the Q-angle, patellar tilt, and patellar spin during double-leg semi-squat and wall-slide semi-squat exercises. However, a significant interaction was observed between squat type and knee angle for patellar spin. We found that the patella is laterally tilted during semi-squat exercises and that there was no difference in patellar tracking between knee flexion during double-leg semi-squat and wall-slide semi-squat exercises.

Evaluation of seismic criteria of built-up special concentrically braced frames

  • Izadi, Amin;Aghakouchak, Ali A.
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.23-37
    • /
    • 2018
  • In this paper, seismic provisions related to built-up special concentrically braced frames (BSCBFs) are investigated under cyclic loading using non-linear finite element analysis of a single-bay single-story frame. These braces, which contain double angle and double channel brace sections, are considered in two types of single diagonal and X-braced frames. The results of this study show that current seismic provisions such as observing the 0.4 ratio for slenderness ratio of individual elements between stitch connectors are conservative in BSCBFs, and can be increased according to the type of braces. Furthermore, such increments will lead to decreasing or remaining the current middle protected zone requirements of each BSCBFs. Failure results of BSCBFs, which are related to the plastic equivalent strain growth of members and ductility capacity of the models, show that the behaviors of double channel back-to-back diagonal braces are more desirable than those of similar face-to-face ones. Also, for double angle diagonal braces, results show that the failure of back-to-back BSCBFs occurs faster in comparison with face-to-face similar braces. In X-braced frames, cyclic and failure behaviors of built-up face-to-face models are more desirable than similar back-to-back braces in general.

Comparison of Single and Double Fusions in Transverse Tarsal Joint (횡족근 관절의 단일 및 이중 유합술의 비교)

  • Youn, Hyun-Kook;Lee, Jong-Seok;Lee, Jin-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the clinical and radiological results of single and double fusions in the transverse tarsal joint. Materials and Methods: Between December 2000 and April 2009, 16 patients (16 feet) who had been treated by fusion of transverse tarsal joint were included in this study. In 8 patients, only talonavicular joint was fused and in the other 8 patients, both talonavicular and calcaneocuboid joints were fused simultaneously. We have measured talo-first metatarsal angle, calcaneal pitch angle, talonavicular coverage angle and presence of adjacent joint arthritis for radiological assessment at both preoperative and last visit. Furthermore, we have evaluated Visual Analogue Scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score and patient's satisfaction. Results: In a single fusion group, VAS was improved from $6.4{\pm}1.4$ to $0.8{\pm}1.0$ (p=0.0011) and AOFAS score was improved from $63.8{\pm}6.2$ to $89.4{\pm}9.8$ (p=0.0012). In a double fusion group, VAS was improved from $8.0{\pm}0.75$ to $2.0{\pm}1.8$ (p=0.0011) and AOFAS score was improved from $60.5{\pm}11.2$ to $89.5{\pm}6.0$ (p=0.0012). In the difference of talo-first metatarsal angle between two groups, a single fused group was more improved than a double fused group (p=0.04). Conclusion: Both single and double fusions are useful and attractive treatment for the transverse tarsal joint arthritis. Furthermore, a single fusion has advantages of less invasiveness and preserving some degree of hindfoot motion and could be an effective alternative to a double fusion if patient meets appropriate criteria through careful preoperative evaluation.

Sound Transmission Loss of Double Panels(I) : A Double Wall with Air Cavity (이중판의 차음손실 I)

  • 강현주;김현실;김재승;김상렬
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.945-952
    • /
    • 1997
  • This paper shows the feasibility of the suggestion that the angle distribution of incident sound to panels might be gaussian, instead of the conventional uniform distribution in the analysis of transmission loss of panels. To prove the suggestion, the problems with the diffuse sound field in a reverberation room are examined by case studies and the comparision of the prediction with the measurement of sound transmission loss of walls are performed. The results of the comparision show good agreement between the two values.

  • PDF

Multi-objective optimization of double wishbone suspension of a kinestatic vehicle model for handling and stability improvement

  • Bagheri, Mohammad Reza;Mosayebi, Masoud;Mahdian, Asghar;Keshavarzi, Ahmad
    • Structural Engineering and Mechanics
    • /
    • v.68 no.5
    • /
    • pp.633-638
    • /
    • 2018
  • One of the important problems in the vehicle design is vehicle handling and stability. Effective parameters which should be considered in the vehicle handling and stability are roll angle, camber angle and scrub radius. In this paper, a planar vehicle model is considered that two right and left suspensions are double wishbone suspension system. For a better analysis of the suspension geometry, a kinestatic model of vehicle is considered which instantaneous kinematic and statics relations are analyzed simultaneously. In this model, suspension geometry is considered completely. In order to optimum design of double wishbones suspension system, a multi-objective genetic algorithm is applied. Three important parameters of suspension including roll angle, camber angle and scrub radius are taken into account as objective functions. Coordinates of suspension hard points are design variables of optimization which optimum values of them, corresponding to each optimum point, are obtained in the optimization process. Pareto solutions for three objective functions are derived. There are important optimum points in these Pareto solutions which each point represents an optimum status in the model. In other words, corresponding to any optimal point, a specific geometric position is determined for the suspension hard points. Each of the obtained points in the Pareto optimization can be selected for a special design purpose by designer to create an optimum condition in the vehicle handling and stability.

Two Cases of Idiopathic Scoliosis with Double Curved Thoracolumbar Spine using Muscle Energy Technique (근에너지기법을 이용한 흉요추부 이중만곡 형태의 특발성 척추 측만증 호전 2례)

  • Lee, Sung-Joon;Lee, Hyuk-Jae;Lee, Yu-Jin
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.12 no.2
    • /
    • pp.63-71
    • /
    • 2017
  • Objectives : The purpose of this study is to report the effect of muscle energy technique(MET) on idiopathic scoliosis with double curved thoracolumbar spine. Methods : Two patients with idiopathic scoliosis with double curved thoracolumbar spine were treated by MET. To investigate the outcome of the patients' improvement, we observed the standing X-ray of cervical, thoracic, lumbar spine. And Cobb's angle, correctability and visual analog scale(VAS) were used to measure changes during treatment. Results : After treatment, Cobb's angle, correctability and VAS were improved significantly. Conclusions : MET showed significant improvement to idiopathic scoliosis with double curved thoracolumbar spine. There is limitation on this study due to insufficient number of cases. Further research should be followed.

  • PDF

Finite Element Analysis of Electrical Double Layers near Triple Contact Lines

  • Kang Kwan Hyoung;Kang In Seok;Lee Choung Mook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.491-494
    • /
    • 2002
  • To assess the electrostatic interaction of surfaces at the triple contact line, the electrostatic field is analyzed by using the finite element method. The Helmholtz free energy is used as a functional which should be minimized under an equilibrium condition. The numerical results are compared with the nonlinear analytical solution for a two-dimensional charged interface and linear solution for a wedge shaped geometry, which shows fairly good agreement. The method is applied to the analysis of electrostatic influence on the contact angle on a charged substrate. The excess free energy found to increase drastically as the contact angle approaches to zero. This excess free energy Plays an opposite role to the Primary electrocapillary effect, as the contact angle gets smaller. This enables an alternative explanation for the contact-angle saturation phenomenon occurring in electrical control of surface tension and contact angle.

  • PDF

Effects of Strake Incidence-Angle on the Vortex Flow of a Double-Delta Wing (스트레이크 붙임각이 이중 삼각날개의 와류에 미치는 영향)

  • 손명환;정형석;장조원
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.7-15
    • /
    • 2006
  • The effects of strake incidence-angle on the vortex characteristics and the wing-surface pressure distribution for a double-delta wing with strake were investigated experimentally. The strake incidence-angle of negative sign(strake is pitched down from the main-wing upper-surface) increased the suction pressure of the wing-upper surface, which was the same effect of increase of angle of attack. This change of the suction pressure was caused by the closer movement of the vortex cores to the wing upper surface rather than the increase of the vortex strength.

A new X-ray cross-sectional image system for solder joint inspection of double-sided PCB (양면 PCB의 납땜부 검사를 위한 새로운 X선 단층영상 시스템)

  • 강성택;정재훈;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.117-120
    • /
    • 1996
  • In this paper, a new approach to acquire the cross-sentional image for automatic solder joint inspection of double-sided PCB using X-ray source is presented. We designed the apparatus with fixed X-ray source to realize the cross-sectional image by tunning object and detector synchronously. The cross-sectional images are captured at several view angle of X-ray source, the geometric image distortions caused by view angle and the shape of image intensifier are compensated. The precision variation of cross-sectional image by the change of view angle was investigated. Also we acquired the cross-sectional image to the solder joint of double-sided PCB and reconstructed the shape of solder joint.

  • PDF