• Title/Summary/Keyword: Double Pipe

Search Result 171, Processing Time 0.026 seconds

Calculation of Stress Intensity Factors Using Single-Layer Potential and Weight Function (Single-Layer 포텐셜과 가중함수를 이용한 응력강도계수의 계산)

  • 이형연;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.4
    • /
    • pp.981-989
    • /
    • 1995
  • A new weight function approach to determine SIF(stress intensity factor) using single-layer potential has been presented. The crack surface displacement field was represented by one boundary integral term whose kernel was modified from Kelvin's fundamental solution. The proposed method enables the calculation of SIF using only one SIF solution without any modification for the crack geometries symmetric in two-dimensional plane such as a center crack in a plate with or without an internal hole, double edge cracks, circumferential crack or radial cracks in a pipe. The application procedure to those crack problems is very simple and straightforward with only one SIF solution. The necessary information in the analysis is two reference SIFs. The analysis results using present closed-form solution were in good agreement with those of the literature.

Characteristics of Hydrocarbon Refrigerants on Evaporating Heat Transfer and Pressure Drop

  • Lee Ho-Saeng;Phan Thanh Tong;Yoon Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.102-109
    • /
    • 2006
  • Experimental results for heat transfer characteristics and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The test sections which has one tube diameter of 12.70 mm with 0.89 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average evaporating heat transfer coefficient increased with the increase of the mass flux, with the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than R-22. Those results from the investigation can be used in the design of heat exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

Study on Evaporation Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 증발 압력강하 특성에 관한 실험적 연구)

  • Lee Kwang-Bae;Lee Ho-Saeng;Kim Jae-Dol;Yoon Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.533-539
    • /
    • 2005
  • Experimental results are presented for heat transfer and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers. Two tubes with a tube diameter of 12.70mm and 9.52mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in 12.7mm and 9.52mm. The results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

The Ground Reinforcement on Daylight Collapsed Block in Driving Work at the National Road No. 3 Line (국도 3호선 터널건설 공사 중 붕락구간에 대한 지반보강)

  • 천병식;정덕교;이태우;정진교
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.02a
    • /
    • pp.14-22
    • /
    • 1999
  • Daylight collapse have been occurred by about 6.$^{0}$ m deep at ground surface which connected to the ground surface and excessive overbreak have been occurred by the space and height of 3.$^1$~6.$^2$m at crown head part of the tunnel during tunnelling of lower-half part after completing upper-half part on tunnelling of a phyllite mountain by NATM method at the construction work of two way-double track national road. This study is a successful illustration case of earth improvement by confirming structural safety of the tunnel in a whole through solving the cause of the tunnel collapse and the work have completed successfully through applying such earth strengthening method as cement mortarㆍcement milk injection, S.G.R, steel pipe reinforced multi-step grouting etc.

  • PDF

Investigation of Actural State of Plastic Greenhouse Structures in Korea (플라스틱 하우스의 구조 실태의 조사 연구)

  • 김문기;고재군;이신호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.3
    • /
    • pp.113-124
    • /
    • 1987
  • The objective of this study was to disclose the problem of structural safety and the state of utilization of standard types of plastic film house through investigation of actural state of plastic greenhouses for the southern part of the Korean peninsula. And also, the application method of standard types were proposed. The results obtained are summarized as follows 1. Plastic film houses investigated were not designed by the structural design conditions of loads and materials. 2.The construction method of greenhouses was not standardized. 3.Single type of standard greenhouses was nearly used and double types were applied to the standard type. 4.The standard frames of plastic film house were appeared to have structural lack of stability at the design snow and wind loads for most regions. 5.Safety snow depths and safety wind velocities were proposed for the frame intervals and pipe diameters of standard greenhouses.

  • PDF

Experimental Analysis on the Heat Transfer Characteristics of the Double Pipe Heat Exchanger for Latent Heat Storage (이중관형(二重管形) 잠열축열장치(潜熱蓄熱裝置)의 전열특성(傳熱特性)에 대(對)한 실험적(實驗的) 분석(分析))

  • Kim, Y.B.;Song, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.1
    • /
    • pp.24-32
    • /
    • 1989
  • 고밀도(高密度)의 열(熱)에너지를 저장(貯藏)하기 위(爲)한 잠열축열장치를 설계(設計), 제작(製作), 작동(作動)하는 경우 잠열축열장치의 사용목적(使用目的)에 적합(適合)한 최적설계(最適設計)와 그 효율적(效率的)인 이용(利用)을 위(爲)해서는 그 부열특성(傅熱特性)이 규명(糾明)되어야 한다. 본(本) 연구(硏究)에서는 실용화(實用化)에 필요(必要)한 이중관형(二重管形) 잠열축열장치의 방열과정(放熱過程)에서의 부열특성(傅熱特性)을 이차원적(二次元的)으로 실험(實驗) 분석(分析)하였으며, 시간변화(時間變化)에 따른 잠열재의 온도변화(溫度變化)와 응고율(凝固率)이 실험분석치(實驗分析値)와 이론분석치(理論分析値)에 있어서 잘 일치하였다. 한편 응고율(凝固率), 방열율(放熱率), 물의 온도변화(溫度變化)에 대(對)한 분석(分析)을 하였다.

  • PDF

A Study on the development of the extended type PE double wall corrugated pipe for the production rate improvement (생산속도 향상을 위한 확장형 PE이중벽관의 개발에 관한 연구)

  • Kim, Ho-Seok;Oh, Seong-Hun;Kim, Hyoung-Jin;Go, Young-Min
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.617-619
    • /
    • 2011
  • 본 논문에서는 기존 PE 이중벽관을 확장형 이중벽으로 제작하여 생산시간을 단축시키는데 그 목적이 있고, 그에 따른 구조적 특징으로 인하여 외압 강도를 향상시킬 수 있으며, 기존 제품에서 발생했던 불량의 원인을 제거할 수 있는 PE 확장형 이중벽관을 개발하는 것이다.

  • PDF

The Heat Transfer Performance with Pumping Power for a Particle Bed Heat Exchanger (입자층(粒子層)을 이용한 열교환기(熱交換器)에서 소요동력(所要動力)에 따른 전열특성(傳熱特性)에 관(關)한 연구(硏究))

  • Yoo, J.O.;Yang, H.J.;Cho, Y.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.351-359
    • /
    • 1992
  • In order to improve the performance of heat exchanger, fluidized bed is often employed. The experiments are carried out in fluidized double pipe parallel flow heat exchanger in which finned tube is vertically immersed. And the heat transfer coefficients between the heated tube and fluidized bed of alumina beads(dp=0.41, 0.54, 0.65, 0.77mm) are calculated as a function of air fluidized velocity and pumping power. The effects of particle size, static bed height and pumping power on the heat transfer coefficients are investigated. And the heat transfer coefficients are compared with that of single phase forced convection heat exchanger. In particular, the heat transfer performance of each type heat exchanger is evaluated in relation to the pumping power.

  • PDF

Study on Condensing Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 응축 압력강하에 관한 연구)

  • Kim, Jae-Dol;Choi, Jun-Hyuk;Jeong, Seok-Kwon;Yoon, Jung-In;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

Characteristics on Evaporating Pressure Drop of HCs Refrigerants inside a horizontal tube (수평관내 HC계 냉매의 증발 압력강하 특성)

  • Choi, Jun-Hyuk;Lee, Ho-Saeng;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.63-64
    • /
    • 2006
  • Chracteristics on evaporating pressure drop of HCs refrigerants inside a horizontal tube were studied experimentally. Experimental results were presented for pressure drops of hydrocarbon refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 inside a horizontal double pipe heat exchanger. Three tubes with a tube diameter of 12.70mm, 9.52mm and 6.35mm were used for this study. Hydrocarbon refrigerants showed higher evaporating pressure drop than that of R-22 in all tubes. The highest pressure drop was founded in R-600a. The highest evaporating perssure drop of all refrigerants was shown in a tube diameter of 6.35mm with same mass flux. The results can be used as the basic data for the design of heat exchanger using hydrocarbon refrigerants as an alternatives.

  • PDF