• 제목/요약/키워드: Double Operation

검색결과 824건 처리시간 0.027초

Analysis on operation characteristics and power burdens of the double quench trigger type SFCLs

  • Lim, Seung-Taek;Lim, Sung-Hun;Han, Tae-Hee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.33-37
    • /
    • 2017
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. The capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system operator need a counter-measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as effective solutions to reduce the fault current. For the above reasons various type SFCLs have been studied recently. In this paper, operation characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. Another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

Quantitative Analysis on Voltage Schemes for Reliable Operations of a Floating Gate Type Double Gate Nonvolatile Memory Cell

  • Cho, Seong-Jae;Park, Il-Han;Kim, Tae-Hun;Lee, Jung-Hoon;Lee, Jong-Duk;Shin, Hyung-Cheol;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권3호
    • /
    • pp.195-203
    • /
    • 2005
  • Recently, a novel multi-bit nonvolatile memory based on double gate (DG) MOSFET is proposed to overcome the short channel effects and to increase the memory density. We need more complex voltage schemes for DG MOSFET devices. In view of peripheral circuits driving memory cells, one should consider various voltage sources used for several operations. It is one of the key issues to minimize the number of voltage sources. This criterion needs more caution in considering a DG nonvolatile memory cell that inevitably requires more number of events for voltage sources. Therefore figuring out the permissible range of operating bias should be preceded for reliable operation. We found that reliable operation largely depends on the depletion conditions of the silicon channel according to charge amount stored in the floating gates and the negative control gate voltages applied for read operation. We used Silvaco Atlas, a 2D numerical simulation tool as the device simulator.

단일 스위치 배전압 방식의 단상 PFC 컨버터의 동작 특성 (Operation Characteristic of Single-phase PFC converter with 1-switch Voltage Doubler Strategy)

  • 구대관;지준근;차귀수;임승범;홍순찬
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.561-568
    • /
    • 2011
  • 본 논문은 단상 이중변환 무정전전원장치를 위한 단일 스위치 배전압 방식의 단상 PFC 컨버터의 동작 특성을 기술한다. 단일 스위치 배전압 방식의 단상 PFC 컨버터는 브릿지 다이오드와 양방향 능동 스위치 한 개만이 필요하며 재료비 절감이 가능하다. 하지만 이 회로가 제안된 후 동작 특성 및 제어기 설계에 대한 연구결과가 알려지지 않았다. 본 논문에서는 동작 특성과 제어기 설계방법을 기술하고 성능평가를 위해 단상 정격 3kVA 이중변환 무정전전원장치를 대상으로 실험을 수행하였다. 또한 실험을 통해 입력전류 제어, 입력역률 보상 성능을 확인하였다.

이중 변환 UPS의 병렬 운전 시 외란 저감 성능 향상을 위한 정지 좌표계 상의 전향 보상 기법 (Feed-Forward Compensation Technique in Stationary Reference Frame for the Enhanced Disturbance Rejection Performance in Parallel Operation of Double-Conversion UPSs)

  • 류효준;윤영두;모재성;최승철;우태겸
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.367-375
    • /
    • 2022
  • Generally, a proportional-resonant controller is used to eliminate steady-state errors during the voltage-current control of a double-conversion uninterruptible power supply (UPS) in a stationary reference frame. Additionally, the feed-forward control compensating for the load current, which can be considered a disturbance of the voltage controller, can be used to improve the disturbance rejection performance. However, during the parallel operation of UPSs, circulating current can occur between UPS modules when performing both feed-forward control and droop control because feed-forward control reduces the circulating current impedance. This study proposes a feed-forward compensation technique that considers the impedance of circulating current. An additional feed-forward compensation technique is developed to enhance the disturbance rejection performance. The validity of the proposed feed-forward compensation technique is verified by the experiment results of the parallel operation of a 500 W double-conversion UPS module.

2층 전동차 시스템 개념설계에 관한 연구 (Concept designs of a double deck EMU train)

  • 김형진;황원주;허현무;백광선;박광복
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.245-250
    • /
    • 2005
  • Currently, many countries in the world operate double deck trains as one of the efficient, reliable and comfortable mass transportation systems. However, double deck trains have relatively big cross sectional areas that cause interface problems between the vehicles and infrastructures, and do not have enough spaces for installing electric equipments. Therefore, prior to the operation of double deck trains on the existing lines in Korea, careful investigations should be performed. In this study, we have designed the concept model of a double deck EMU train system and analyzed related problems.

  • PDF

Double-Cage 건설용 리프트의 양중시간 산정을 위한 시뮬레이션 모델 개발 (The Development of Simulation Model for Calculating Hoisting Time of Double-Cage Construction Lift in Supertall Building Construction)

  • 김완섭;이동민;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.64-65
    • /
    • 2016
  • According to the recent increase in the height of supertall buildings, construction lift became one of most important equipment for vertical transportation of resources. However, increase in lifting load during peak time in which the resources are concentrated often causes a risk of construction delay. This study suggests a concept of Double-Cage construction lift, which is a lift with two cages attached together allowing transportation of resources on two consecutive work floors simultaneously. The aim of this study is to present a simulation model suitable for calculating hoisting time of Double-Cage construction lift. The proposed model is expected to be utilized when applying Double-cage construction lift for its efficient operation and management.

  • PDF

고속 래피어 직기용 바듸침 캠의 최적설계 (Optimum Design of Beating Cam for High Speed Rapier Loom)

  • 김종수;김대원
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.89-100
    • /
    • 1998
  • This paper deals with the design and analysis of a beating cam. The beating device of a high speed rapier loom, weaving fabric by completion of warp-weft patterns, is driven by double cam type on the same axis. As the double cam, coupled with two cams, performs the mutual conjugate motion, the double cam must be very preciously designed for smooth. For the shape design of a double cam, an instant velocity center method is proposed. This method can determine the cam profile from the contact conditions of the cam and roller follower and the velocity relationships at the instant velocity center. And the practical applicability was verified by developing “DISKCAM of a CAD program. As the results in this paper, the shapes of two cams, which are in the conjugate motion, are designed by instant velocity center method. We applied 8-order polynominals for the beating as displace¬ment curves for shape determination of double cams. The data of displacement, velocity, and acceleration of beating cam can be used adjust in accurate operation and to develope an advanced beating device.

  • PDF

고온 초전도 더블 팬케이크의 접합 수 감소를 위한 권선 방법에 관한 연구 (A Study on the Winding Method for Reducing Joints of the High Temperature Superconducting Double Pancake Coil)

  • 강재식;조현철;장재영;황영진;이지호;이우승;박영건;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.30-33
    • /
    • 2012
  • A double pancake winding method is widely used to make the superconducting magnet, using high temperature superconductor (HTS) tape. In the double pancake winding method, the joints with contact resistances between double pancake coils are inevitably needed. The electrical joule heating on the contacts causes refrigerant loss during operation. And a space outside the winding, for splices and mechanical support, is more than that for its layer-wound equivalent. In this paper, a double pancake winding method in order to reduce the number of the joints was proposed. Both of the double pancake coils using the conventional winding method and the proposed winding method have been fabricated and tested to make the solution technically feasible in the double pancake winding method. Especially, critical-current tests of the fabricated double pancake coils were conducted in order to show the same performance and confirm contact resistances between double pancake coils.