• 제목/요약/키워드: Double Facade System

검색결과 27건 처리시간 0.019초

이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가 (A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings)

  • 석호태;김동화;최정민
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

다양한 기후조건에 대응하는 이중외피시스템 개발에 관한 실험적 연구 (Experimental Study on Developing of Double Facade System dealing with the various climatic Conditions)

  • 이건호;김현수;장대희;문수영
    • KIEAE Journal
    • /
    • 제5권2호
    • /
    • pp.19-26
    • /
    • 2005
  • Every site has a different given geometrical and climatic condition, which influenced not only the lifestyle of the humanbeings but also the regional architecture. For example, on a cold region, the reduction of the energy loss is necessary, like an igloo, which has a littlest energy loss at hemisphere. Or on a warm region, the house must be protected thermally from the overheating at the sunshining. like a huge shading. An architectural interpretation in the (extreme) moderate climate, like Korea, has always tried to satisfy the both opposite demands simultaneously. A facade, which divides out- and inside, has an ideal position to lead the regulated regional climatic conditions into the room. The Double Facade System(DFS) is well known as an innovative solution in the european countries, like Germany. It provides an reasonable alternative, which can achieve these goals at the same time. A Double Facade System provides an effective sunshade, which means a cooling energy reduction at the warm season. In addition, it enables a natural ventilation at the cold season with the preheating at the system as well as spring and autumn. An ordinary Single Facade System with a inside or outside sun blind provides a solution just for a specified season, like a summer or winter. But the Double Facade System can deal with the various climatic conditions in the moderate climate.

이중외피시스템의 차음성능 평가에 관한 연구 -전면형 이중외피시스템을 중심으로- (A Study on the Evaluation of Sound Insulation Performance of Double Skin Facade -Focus on the Multi-story type of Double Skin Facade-)

  • 석호태;차민철
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.11-18
    • /
    • 2004
  • The purpose of this study is to evaluate the sound insulation performance and present fundamental data for sound insulation plan about open and close windows of inner facade and outer facade of Double-skin Facade system applied to multi-story type. The Headquarter of Green Building and the Energy Saving Building in the Korea Institute of Energy Research was selected for experiment. Measurement method which are specified in the Korea Standard 2235 were selected for this study. As the result of this study, 1) Sound insulation performance of Multi-layer type of Double-skin Facades is very excellent about outdoor noise. 2) Vertical level is higher, it shows that more decreases sound pressure level.

박스형 이중외피와 커튼월 창호의 난방기 열적성능 비교 (A Study on thermal performance of box type double skin facade and curtain wall in heating period)

  • 박창영;최창호;이건호;윤용상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.909-914
    • /
    • 2006
  • The purpose of this study is to analyze the thermal of DFS(double Facade System) and curtain wall in the heating period. The physical difference between curtain wall and double facade on thermal performance has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. This study divide on 'ventilated, airtight' and 'heated or unheated' conditions from the CASE 1, 2, 3, 4. The results showed thermal performance of double facade system which has been better than curtain wall. The heating energy of DFS reduced $8%{\sim}10%$ of energy consumption. comparable to SFS in experemted results. In view of the researching results so far achieved, the research came to a conclusion, that the curtain wall can save the energy in the heating period than a curtain wall.

  • PDF

Evaluation of the effect of smart façade systems in reducing dynamic response of structures subjected to seismic loads

  • Samali, Bijan;Abtahi, Pouya
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.983-1000
    • /
    • 2016
  • To date the engineering community has seen facade systems as non-structural elements with high aesthetic value and a barrier between the outdoor and indoor environments. The role of facades in energy use in a building has also been recognized and the industry is also witnessing the emergence of many energy efficient facade systems. This paper will focus on using exterior skin of the double skin facade system as a dissipative movable element during earthquake excitation. The main aim of this study is to investigate the potential of the facade system to act as a damper system to reduce earthquake-induced vibration of the primary structure. Unlike traditional mass dampers, which are usually placed at the top level of structures, the movable/smart double skin facade systems are distributed throughout the entire height of building structures. The outer skin is moveable and can act as a multi tuned mass dampers (MTMDs) that move and dissipate energy during strong earthquake motions. In this paper, using a three dimensional 10-storey building structure as the example, it is shown that with optimal choice of materials for stiffness and damping of brackets connecting the two skins, a substantial portion of earthquake induced vibration energy can be dissipated which leads to avoiding expensive ductile seismic designs. It is shown that the engineering demand parameters (EDPs) for a low-rise building structures subjected to moderate to severe earthquakes can be substantially reduced by introduction of a smart designed double skin system.

난방기 중 이중외피 시스템의 자연환기 성능분석에 관한 실험적 연구 (Experimental Study on Natural Ventilation Performance of Double Facade System in Heating Period)

  • 이건호;김현수;고영우;손영주
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.43-50
    • /
    • 2006
  • A Double Facade System(DFS) is well known as an innovative solution of ecological facade in the west european countries. There are more than 200 various realized DFS in Germany. At the same time, the korean engineers have researched to find out the physical advantages of DFS in the moderate korean climate, which has a very humid summer with high temperature and a dry winter with low temperature. For example, the monthly mean temperature in Korea comes up to 28K, while that in Germany comes up to only 19K. That is, why a other solution of DFS is needed in Korea. This study has experimented the physical performance of the natural ventilation in the heating period. The preheating function of the cold air by DFS can improve no doubt the performance of the natural ventilation at the cold season as well as spring and autumn. The physical difference between single and double facade on natural ventilation has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. The results show the natural ventilation of the DFS has definitely much more comfortable than that of the single facade system. The air velocity of the inflow as well as the air temperature in the DFS provide a more stable condition than in the SFS. The theoretical limit(air velocity max 0.2m/s, air temperature min. $18^{\circ}C$, temperature difference between 100mm and 1700mm height max. 3K) on the indoor comfortableness doesn't go over in the DFS. On the other hand, the SFS showed an unstable condition with an excess of comfortableness limit on air velocity as well as temperature. In view of the researching results so far achieved, the research came to a conclusion, that the DFS can provide a more comfortable indoor condition by the preheating in the heating period than a SFS, and the period of natural ventilation in winter time could be definitely increased at the DFS.

PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구 (A Study on the Performance of Blind type Double-Skin Facade System with PV modules)

  • 조혜진;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰 (Analysis for Fire Spread through Double Skin Facade System with FDS)

  • 허윤택;박창복;성준식;윤명오
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-116
    • /
    • 2009
  • 본 연구는 Double Skin System의 화재 전파 위험성을 전산유체역학모델인 FDS를 이용하여 평가하였다. 화재모델링을 구현하기 위해 오피스 용도의 단위 구획공간을 화재지역으로 선정하였으며, 화재시나리오는 외창으로의 연소확대 위험 분석을 위하여 일반적으로 많이 설치되는 시스템조건들을 Case로 선정하여 분석하였다. 본 연구의 목적은 일반적으로 많이 사용되는 Double Skin System의 설치 간격에 따른 건물상층부로의 화재확대 위험성을 평가하고, 이에 따른 방화대책 등을 수립하는데 있다. 해석 결과, 더블스킨 중간층 간격이 넓을수록 상부층으로 연소확대 영향이 작은 것을 확인할 수 있었으며, 중간층 간격이 1m 미만인 경우는 발화층 상부 2개층으로 연소확대가 예상되므로 층간연소 확대 방지 시스템이 요구됨을 알 수 있다.

동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구 (The Characteristics of the winter season window and indoor temperature due to the indoor plant)

  • 윤영일;조주영
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

오피스 건물에 적용된 다층형 이중외피의 풍압과 실내·외 온도차에 의한 환기량 변화 분석 (The Analysis on the Variation of the Ventilation Rates by Wind Pressure and Temperature Difference between Indoor and Outdoor in the Multi-Story Type Double Skin Facade applied to the Office Building)

  • 송치호;김태연;이승복
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.123-131
    • /
    • 2015
  • Purpose : Improvement of indoor thermal comfort and reduction of the energy consumption in building can be obtained by applying a double skin facade system. In order to achieve effectively this purpose, design team would have to perform easy and appropriate performance analysis for making better design decision during the design process. Method : This paper focus on the natural ventilation performance of a multi-story type double skin facade with main causes which are pressure difference according to the wind and temperature difference between indoor and outdoor (Buoyancy Effect). Using this main causes, the natural ventilation ratio of wind effect-to-buoyancy effect in cavity of multi-story type double skin facade were analyzed through the performance analysis results of CFD (Computational Fluid Dynamics) simulation. Result : When the wind velocity was 2m/s, the ventilation rate in the cavity was highest. If wind velocity was slower than 2m/s wind velocity, buoyancy effect has more influence on the ventilation rate in the cavity, and if wind velocity was faster than 2m/s wind velocity, wind effect has more influence on the ventilation rate in the cavity.