• Title/Summary/Keyword: Double Base

Search Result 306, Processing Time 0.027 seconds

Key technologies research on the response of a double-story isolated structure subjected to long-period earthquake motion

  • Liang Gao;Dewen Liu;Yuan Zhang;Yanping Zheng;Jingran Xu;Zhiang Li;Min Lei
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.17-30
    • /
    • 2024
  • Earthquakes can lead to substantial damage to buildings, with long-period ground motion being particularly destructive. The design of high-performance building structures has become a prominent focus of research. The double-story isolated structure is a novel type of isolated structure developed from base isolated structure. To delve deeper into the building performance of double-story isolated structures, the double-story isolated structure was constructed with the upper isolated layer located in different layers, alongside a base isolated structure for comparative analysis. Nonlinear elastoplastic analyses were conducted on these structures using different ground motion inputs, including ordinary ground motion, near-field impulsive ground motion, and far-field harmonic ground motion. The results demonstrate that the double-story isolated structure can extend the structural period further than the base isolated structure under three types of ground motions. The double-story isolated structure exhibits lower base shear, inter-story displacement, base isolated layer displacement, story shear, and maximum acceleration of the top layer, compared to the base isolated structure. In addition, the double-story isolated structure generates fewer plastic hinges in the frame, causes less damage to the core tube, and experiences smaller overturning moments, demonstrating excellent resistance to overturning and a shock-absorbing effect. As the upper isolated layer is positioned higher, the compressive stress on the isolated bearings of the upper isolated layer in the double-story isolated structure gradually decreases. Moreover, the compressive stress on the isolated bearings of the base isolated layer is lower compared to that of the base isolated structure. However, the shock-absorbing capacity of the double-story isolated structure is significantly increased when the upper isolated layer is located in the middle and lower section. Notably, in regions exposed to long-period ground motion, a double-story isolated structure can experience greater seismic response and reduced shock-absorbing capacity, which may be detrimental to the structure.

Algorithm and Design of Double-base Log Encoder for Flash A/D Converters

  • Son, Nguyen-Minh;Kim, In-Soo;Choi, Jae-Ha;Kim, Jong-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.4
    • /
    • pp.289-293
    • /
    • 2009
  • This study proposes a novel double-base log encoder (DBLE) for flash Analog-to-Digital converters (ADCs). Analog inputs of flash ADCs are represented in logarithmic number systems with bases of 2 and 3 at the outputs of DBLE. A look up table stores the sets of exponents of base 2 and 3 values. This algorithm improves the performance of a DSP (Digital Signal Processor) system that takes outputs of a flash ADC, since the double-base log number representation does multiplication operation easily within negligible error range in ADC. We have designed and implemented 6 bits DBLE implemented with ROM (Read-Only Memory) architecture in a $0.18\;{\mu}m$ CMOS technology. The power consumption and speed of DBLE are better than the FAT tree and binary ROM encoders at the cost of more chip area. The DBLE can be implemented into SoC architecture with DSP to improve the processing speed.

  • PDF

Constraint Algorithm in Double-Base Number System for High Speed A/D Converters

  • Nguyen, Minh Son;Kim, Man-Ho;Kim, Jong-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.430-435
    • /
    • 2008
  • In the paper, an algorithm called a Constraint algorithm is proposed to solve the fan-in problem occurred in ADC encoding circuits. The Flash ADC architecture uses a double-base number system (DBNS). The DBNS has known to represent the multi-dimensional logarithmic number system (MDLNS) used for implementing the multiplier accumulator architecture of FIR filter in digital signal processing (DSP) applications. The authors use the DBNS with the base 2 and 3 to represent binary output of ADC. A symmetric map is analyzed first, and then asymmetric map is followed to provide addition read DBNS to DSP circuitry. The simulation results are shown for the Double-Base Integer Encoder (DBIE) of the 6-bit ADC to demonstrate an effectiveness of the Constraint algorithm, using $0.18{\mu}\;m$ CMOS technology. The DBIE’s processing speed of the ADC is fast compared to the FAT tree encoder circuit by 0.95 GHz.

New Multiplier for a Double-Base Number System Linked to a Flash ADC

  • Nguyen, Minh-Son;Kim, In-Soo;Choi, Kyu-Sun;Lim, Jae-Hyun;Choi, Won-Ho;Kim, Jong-Soo
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.256-259
    • /
    • 2012
  • The double-base number system has been used in digital signal processing systems for over a decade because of its fast inner product operation and low hardware complexity. This letter proposes an innovative multiplier architecture using hybrid operands. The multiplier can easily be linked to flash analog-to-digital converters or digital systems through a double-base number encoder (DBNE) for realtime signal processing. The design of the DBNE and the multiplier enable faster digital signal processing and require less hardware resources compared to the binary processing method.

Accelerated Aging Characteristics of a Double Base Propellant (복기추진제의 가속 노화 특성 연구)

  • Go, Cheongah;Park, Youngchul;Seo, Taeseok;Moon, Youngtaek;Kim, Junhyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.61-69
    • /
    • 2019
  • Accelerated aging test for the double base propellant was carried out at three different temperatures (60, 70, and $75^{\circ}C$) for over a year. To evaluate the aging characteristics of the double base propellant, the stabilizer contents and thermal decomposition kinetics were analyzed by using high performance liquid chromatography (HPLC) and AKTS-Thermokinetics software. As a result, stabilizer contents in the double base propellant gradually decreased according to the aging temperature and aging duration. The consumption rate of 2-NDPA in the accelerated aged propellants showed that it was two times faster at $75^{\circ}C$ in compared with ther rate at $70^{\circ}C$. These experimental values were simulated by the SB kinetic model, and it was shown that the two-step model with constant reaction orders n1=1 and n2=0 best describes the process of the stabilizer depletion for the double base propellant.

Storage Lifetime Improvement of Zr-Ni K1 Delay System (Zr-Ni계 지연관 결합체(K1) 저장수명 향상)

  • Chang, Il-Ho;Back, Seung-Jun;Jung, Eun-Jin;Son, Young-Kap
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.336-341
    • /
    • 2010
  • The burning interruption between the initiator and the delay column in a Zr-Ni K1 delay system used for a K510 fuze occurs with long-time storage. About 10 % failure probability of 15-years stored delay systems shows the failure mode in open literature. This paper shows storage lifetime improvement results for the delay system through changing the single-base delay column into double-base ones and controlling the manufacturing processes especially the initial inclusion of humidity. The double-base delay columns was implemented by inserting one delay column of fast burning rates between the initiator and the previous delay column of slow burning rates. Accelerated aging tests of the delay systems with double-base columns, and then the firing tests were performed to evaluate the improved lifetime. The double-base delay columns shows improved storage lifetime of the delay system through preventing the failure mode.

A New Multiplication Architecture for DSP Applications

  • Son, Nguyen-Minh;Kim, Jong-Soo;Choi, Jae-Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.2
    • /
    • pp.139-144
    • /
    • 2011
  • The modern digital logic technology does not yet satisfy the speed requirements of real-time DSP circuits due to synchronized operation of multiplication and accumulation. This operation degrades DSP performance. Therefore, the double-base number system (DBNS) has emerged in DSP system as an alternative methodology because of fast multiplication and hardware simplicity. In this paper, authors propose a novel multiplication architecture. One operand is an output of a flash analog-to-digital converter (ADC) in DBNS format, while the other operand is a coefficient in the IEEE standard floating-point number format. The DBNS digital output from ADC is produced through a new double base number encoder (DBNE). The multiplied output is in the format of the IEEE standard floating-point number (FPNS). The proposed circuits process multiplication and conversion together. Compared to a typical multiplier that uses the FPNS, the proposed multiplier also consumes 45% less gates, and 44% faster than the FPNS multiplier on Spartan-3 FPGA board. The design is verified with FIR filter applications.

Research of Stresses Distribution and Loading Weight on Concrete Electric Pole Considering Field Condition (설치조건을 고려한 배전용 콘크리트전주의 응력분포 및 하중에 관한 연구)

  • Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.183-188
    • /
    • 2004
  • A method of double-pole construction is developing to strengthen the mechanical intensity of the electric poles. Therefore the mechanical properties of the double-pole were researched in this paper. First, considering field special quality electric poles were established. In the next tensile force was applied and stress distribution and fatigue load were examined. When a base of the pole is concrete, mechanical intensity of the double-pole increased about 1.7 times compared a single pole. In the case of general soil base, the concrete base should be needed to expect the reinforcement effect of the double-pole.

Burning Rate Testing of Double Base Solid Propellants using Ultrasound (초음파를 이용한 Double Base형 고체추진제의 연소속도 측정)

  • Song, Sung-Jin;Ko, Sun-Feel;Kim, Hak-Joon;Oh, Hyun-Taek;Kim, In-Chul;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.247-250
    • /
    • 2006
  • In the previous study, we have developed an ultrasonic measurement system and analysis technique for borning rate testing of solid propellants using ultrasound. And then, using the developed system, burning rate of composite propellants were measured. So, in this study, we performed measurement of double base solid propellant, which has non-linear homing rate as pressure increasing, using the developed system in order to evaluate capability of ultrasonic method. Furthermore, accuracy of measured homing rates using ultrasound was verified by comparison to homing rate measured by the strand burner method.

  • PDF

Earthquake response of isolated cable-stayed bridges under spatially varying ground motions

  • Ates, Sevket;Soyluk, Kurtulus;Dumanoglu, A. Aydin;Bayraktar, Alemdar
    • Structural Engineering and Mechanics
    • /
    • v.31 no.6
    • /
    • pp.639-662
    • /
    • 2009
  • A comprehensive investigation of the stochastic response of an isolated cable-stayed bridge subjected to spatially varying earthquake ground motion is performed. In this study, the Jindo Bridge built in South Korea is chosen as a numerical example. The bridge deck is assumed to be continuous from one end to the other end. The vertical movement of the stiffening girder is restrained and freedom of rotational movement on the transverse axis is provided for all piers and abutments. The longitudinal restraint is provided at the mainland pier. The A-frame towers are fixed at the base. To implement the base isolation procedure, the double concave friction pendulum bearings are placed at each of the four support points of the deck. Thus, the deck of the cable-stayed bridge is isolated from the towers using the double concave friction pendulum bearings which are sliding devices that utilize two spherical concave surfaces. The spatially varying earthquake ground motion is characterized by the incoherence and wave-passage effects. Mean of maximum response values obtained from the spatially varying earthquake ground motion case are compared for the isolated and non-isolated bridge models. It is pointed out that the base isolation of the considered cable-stayed bridge model subjected to the spatially varying earthquake ground motion significantly underestimates the deck and the tower responses.