• 제목/요약/키워드: Dosimetric comparison

검색결과 72건 처리시간 0.026초

방사선 선량의 표준 측정법(한국의학물리학회 1990) 및 TG-21, $C_{\lambda}/C_E$ 방법의 비교 (The Comparison of the KAPM Dosimetric Protocol (1990) with the TG-21 and $C_{\lambda}/C_E$ Method)

  • 이병용;최은경;장혜숙
    • Radiation Oncology Journal
    • /
    • 제9권2호
    • /
    • pp.337-342
    • /
    • 1991
  • 방사선 선량의 표준측정법 (한국의학 물리학회 1990) 및 TG-21, $C_{\lambda}/C_E$ 방법을 비교 연구하였다. 방사선 치료에서 사용되는 광자선과(4MV-l5MV) 전자선(6MeV-20MeV)을 세 종류의 전리함으로 물팬틈속에서 측정, 평가한 결과를 비교하였다. TG-21과 방사선 선량의 표준 측정법 비교에서는1$\%$ 이내의 작은 차이만을 보여주었으며 그 차이는 주로 $N_{D}-N_{gas}$ 차이에서 나오는 것으로 평가되었다. 그러나 $C_{\lambda}/C_E$ 방법과의 비교에서는 광자선의 경우 $-1.9{\pm}0.6\%$ (방사선 선량의 표준 측정에 의한 결과가 높게 나옴) 전자선의 경우 $3.3{\pm}1\%$(방사선 선량의 표준측정법에 의한 결과가 낮게 나옴)의 차이를 보였다.

  • PDF

Dosimetric comparison between modulated arc therapy and static intensity modulated radiotherapy in thoracic esophageal cancer: a single institutional experience

  • Choi, Kyu Hye;Kim, Jina;Lee, Sea-Won;Kang, Young-nam;Jang, HongSeok
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.63-70
    • /
    • 2018
  • Purpose: The objective of this study was to compare dosimetric characteristics of three-dimensional conformal radiotherapy (3D-CRT) and two types of intensity-modulated radiotherapy (IMRT) which are step-and-shoot intensity modulated radiotherapy (s-IMRT) and modulated arc therapy (mARC) for thoracic esophageal cancer and analyze whether IMRT could reduce organ-at-risk (OAR) dose. Materials and Methods: We performed 3D-CRT, s-IMRT, and mARC planning for ten patients with thoracic esophageal cancer. The dose-volume histogram for each plan was extracted and the mean dose and clinically significant parameters were analyzed. Results: Analysis of target coverage showed that the conformity index (CI) and conformation number (CN) in mARC were superior to the other two plans (CI, p = 0.050; CN, p = 0.042). For the comparison of OAR, lung V5 was lowest in s-IMRT, followed by 3D-CRT, and mARC (p = 0.033). s-IMRT and mARC had lower values than 3D-CRT for heart $V_{30}$ (p = 0.039), $V_{40}$ (p = 0.040), and $V_{50}$ (p = 0.032). Conclusion: Effective conservation of the lung and heart in thoracic esophageal cancer could be expected when using s-IMRT. The mARC was lower in lung $V_{10}$, $V_{20}$, and $V_{30}$ than in 3D-CRT, but could not be proven superior in lung $V_5$. In conclusion, low-dose exposure to the lung and heart were expected to be lower in s-IMRT, reducing complications such as radiation pneumonitis or heart-related toxicities.

Dosimetric Plan Comparison of Accelerated Partial Breast Irradiation (APBI) Using CyberKnife

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Park, Seungwoo;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.73-80
    • /
    • 2018
  • Accelerated partial breast irradiation (APBI) is a new treatment delivery technique that decreases overall treatment time by using higher fractional doses than conventional fractionation. Here, a quantitative analysis study of CyberKnife-based APBI was performed on 10 patients with left-sided breast cancer who had already finished conventional treatment at the Inha University Hospital. Dosimetric parameters for four kinds of treatment plans (3D-CRT, IMRT, VMAT, and CyberKnife) were analyzed and compared with constraints in the NSABP B39/RTOG 0413 protocol and a published CyberKnife-based APBI study. For the 10 patients recruited in this study, all the dosimetric parameters, including target coverage and doses to normal structures, met the NSABP B39/RTOG 0413 protocol. Compared with other treatment plans, a more conformal dose to the target and better dose sparing of critical structures were observed in CyberKnife plans. Accelerated partial breast irradiation via CyberKnife is a suitable treatment delivery technique for partial breast irradiation and offers improvements over external beam APBI techniques.

Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma

  • Paik, Eun Kyung;Kim, Mi-Sook;Choi, Chul Won;Jang, Won Il;Lee, Sung Hyun;Choi, Sang Hyoun;Kim, Kum Bae;Lee, Dong Han
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.233-241
    • /
    • 2015
  • Purpose: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters. Materials and Methods: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions. The dosimetric parameters of planning target volume (PTV) coverage and normal tissue sparing in the RapidArc and the CyberKnife plans were analyzed. Results: The conformity index was $1.05{\pm}0.02$ for the CyberKnife plan, and $1.13{\pm}0.10$ for the RapidArc plan. The homogeneity index was $1.23{\pm}0.01$ for the CyberKnife plan, and $1.10{\pm}0.03$ for the RapidArc plan. For the normal liver, there were significant differences between the two plans in the low-dose regions of $V_1$ and $V_3$. The normalized volumes of $V_{60}$ for the normal liver in the RapidArc plan were drastically increased when the mean dose of the PTVs in RapidArc plan is equivalent to the mean dose of the PTVs in the CyberKnife plan. Conclusion: CyberKnife plans show greater dose conformity, especially in small-sized tumors, while RapidArc plans show good dosimetric distribution of low dose sparing in the normal liver and body.

Dosimetric Comparison of Noncoplanar and Coplanar Volumetric Modulated Arc Therapy Plans for Esophageal Cancer

  • Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.179-188
    • /
    • 2020
  • Purpose: We compared noncoplanar volumetric modulated arc therapy (ncVMAT) plans to coplanar VMAT (cVMAT) plans by evaluating the dosimetric quality of each for esophageal cancer. Methods: Twenty patients treated for esophageal cancer with the cVMAT technique were retrospectively selected. The cVMAT plans consisted of three coplanar full arc beams. The ncVMAT plans consisted of two coplanar full arc beams and one noncoplanar partial arc beam ranging from 45° to 315° with a couch rotation angle of 315°±5°. For dosimetric evaluation, the dose-volumetric (DV) parameters of the planning target volume (PTV) and organs at risk (OARs) were calculated for all VMAT plans. Results: No clinically noticeable differences between the cVMAT and ncVMAT plans were observed in the DV parameters of the PTV. For the lungs, the V13 Gy and mean dose for ncVMAT plans were smaller than those for cVMAT plans, showing statistically significant differences. For the heart, the values of the maximum dose for cVMAT and ncVMAT plans were 53.8±2.9 and 50.9±3.3 Gy, respectively (P=0.004). For the spinal cord, the values of the maximum dose for cVMAT and ncVMAT plans were 37.1±5.1 and 34.7±5.7 Gy, respectively (P<0.001). Conclusions: The use of ncVMAT plans provides better PTV coverage and sparing of OARs compared to that of cVMAT plans for long, tube-like esophageal cancer. For esophageal cancer, the ncVMAT plans showed a more favorable plan quality than the cVMAT plans.

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권11호
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

Dosimetric evaluation of Tomotherapy and four-box field conformal radiotherapy in locally advanced rectal cancer

  • Yu, Mina;Jang, Hong Seok;Jeon, Dong Min;Cheon, Geum Seong;Lee, Hyo Chun;Chung, Mi Joo;Kim, Sung Hwan;Lee, Jong Hoon
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.252-259
    • /
    • 2013
  • Purpose: To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Materials and Methods: Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, $V_{nGy}$, $D_{min}$, $D_{max}$, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Results: Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p = 0.001). But, $V_{26.25Gy}$ and $V_{27.5Gy}$ were not significantly different between the two modalities. Tomotherapy showed higher $D_{max}$ and lower $D_{min}$. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. Conclusion: In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

Benefit of volumetric-modulated arc therapy over three-dimensional conformal radiotherapy for stage I-II extranodal marginal zone B-cell lymphoma of mucosa-associated lymphoid tissue in the stomach: a dosimetric comparison

  • Chung, Joo-Hyun;Na, Kyoungsu;Kim, Il Han
    • Radiation Oncology Journal
    • /
    • 제36권4호
    • /
    • pp.332-340
    • /
    • 2018
  • Purpose: To retrospectively analyze dosimetric parameters of volumetric-modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3D-CRT) delivered to extranodal marginal zone B-cell lymphomas of mucosa-associated lymphoid tissue in the stomach (gastric MALT lymphoma) to find out advantages of VMAT and conditions for definite benefits of VMAT. Materials and Methods: Fifty patients with stage I-II gastric MALT lymphoma received VMAT (n = 14) or 3D-CRT (n = 36) between December 2005 and April 2018. Twenty-seven patients were categorized according to whether the planning target volume (PTV) overlaps kidney(s). Dosimetric parameters were analyzed by dose-volume histogram. Results: Radiation dose to the liver was definitely lower with VMAT in terms of mean dose (p = 0.026) and V15 (p = 0.008). The V15 of the left kidney was lower with VMAT (p = 0.065). For those with PTV overlapping kidney(s), the left kidney V15 was significantly lower with VMAT. Furthermore, the closer the distance between the PTV and kidneys, the less the left kidney V15 with VMAT (p = 0.037). Delineation of kidney(s) by integrating all respiratory phases had no additional benefit. Conclusions: VMAT significantly increased monitor units, reduced treatment time and radiation dose to the liver and kidneys. The benefit of VMAT was definite in reducing the left kidney V15, especially in geometrically challenging conditions of overlap or close separation between PTV and kidney(s).

유방암 환자의 방사선치료에 있어서 순치료계획 세기변조방사선치료법과 쐐기접선조사기법의 선량측정 비교 (Dosimetric Advantages of the Field-in-field Plan Compared with the Tangential Wedged Beams Plan for Whole-breast Irradiation)

  • 김수지;최윤석
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.199-204
    • /
    • 2014
  • 유방암 환자들에 대한 방사선치료에서 순치료계획 세기변조방사선치료법을 쐐기접선조사기법과 선량측정면에서 비교분석하고자 이 연구를 수행했다. 우측 유방암 환자 20명과 좌측 유방암 환자 10명에 대해 후향적으로 연구를 시행했다. 각 환자에 대해 쐐기접선조사기법과 순치료계획 세기변조방사선치료법을 이용한 방사선치료 계획을 수립한 후에 선량학적 분석을 시도했다. 방사선치료계획용 표적체적에 대한 선량학적 비교 분석을 위해 homogeneity index, conformity index, uniformity index를 사용했다. 또한 폐와 심장에 대한 선량학적 분석을 위해서 평균선량값과 10, 20, 30 Gy 이상을 조사받는 체적의 백분율을 비교했다. 순치료계획 세기변조방사선치료법은 쐐기접선조사기법에 비해 계획표적체적에 대해 선량측정면에서 통계적으로 의미있게 더 나은 결과를 보였다. 폐에 대한 방사선량도 순치료계획 세기변조방사선치료법을 사용했을 때 10 Gy, 30 Gy 이상 조사받는 체적의 백분율이 통계적으로 의미있게 낮았다. 좌측 유방암 환자들에서 심장에 대한 방사선량을 측정했을 때에도 순치료계획 세기변조방사선치료법을 사용했을 때 평균선량값, 20 Gy, 30 Gy이상 조사받는 체적의 백분율이 더 낮은 것을 알 수 있었다. 순치료계획 세기변조방사선치료법은 쐐기접선조사기법에 비해 유방의 표적체적에 대한 선량균일성, 적합성 등에서 더 나은 결과를 보였다. 또한 순치료계획 세기변조방사선치료법을 사용했을 때 폐와 심장에 대한 방사선량도 더 낮출 수 있었다.

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.