• Title/Summary/Keyword: Dose indicator

검색결과 113건 처리시간 0.34초

Calculation of an Indicator for Early Death Using Atomic Bomb Survivors' Data

  • Sasaki, Michiya;Fujimichi, Yuki;Yoshida, Kazuo;Iwasaki, Toshiyasu
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.22-29
    • /
    • 2022
  • Background: A comprehensive, traceable, and easy-to-understand radiation risk indicator is desired for radiological protection. The early-onset hypothesis could be used for this purpose. Materials and Methods: An indicator for early death (IED) was developed and calculated using the epidemiological dataset from the 14th Report of the Life Span Study (LSS) of Hiroshima and Nagasaki. By clarifying the calculation process, IED for all-cause mortality was estimated. In addition, the characteristics of IED for solid cancer mortality and cardiovascular mortality as well as those of men and women, and their dependence on age at exposure were investigated for detailed analysis. Results and Discussion: The IED for all-cause mortality was estimated to be approximately 4 years for an acute radiation exposure of 1 Gy regardless of the fitting dose range. The cumulative death rate for all solid cancers also indicated the early-death tendency (approximately 7-10 years at 1 Gy). Although, there is a slight difference in the characteristics of the risk obtained from the LSS study and this study, it is considered that the IED in a unit of years can also be used to show the overall picture of risk due to radiation exposure. Conclusion: We developed and calculated the indicator for early death, IED, for the cumulative mortality rate of all causes of death, all solid cancers, and circulatory diseases. The quantitative values of IED were estimated to be 4 years for all causes of death, 7-10 years for all solid cancers. IED has an advantage for intuitively understanding the meaning of radiation risk since it can be obtained by a simple and traceable method.

Development of rapid. sensitive and reproducible paraquat analysis method in the postmortem specimens.

  • Sihn, Y.S.;Baeck, S.K.;Kim, S.C.;Park, Y.S.
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.284.3-285
    • /
    • 2002
  • Paraquat(methyl viologen) is a bis-quaternary ammonium compound as a wide range herbicide. which was first introduced as an oxidation-reduction indicator dye. When paraquat(fatal dose. 1-2g) was administered to men, the oxido-reduction system of cell was repeatedly acted to perpetuate the cell membrane system, Many death cases had been occurred after ingestion of paraquat around Daejon area for the last six months. (omitted)

  • PDF

다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발 (Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors)

  • 이광재;이연성
    • 센서학회지
    • /
    • 제25권6호
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.

Construction and Preliminary Immunobiological Characterization of a Novel, Non-Reverting, Intranasal Live Attenuated Whooping Cough Vaccine Candidate

  • Cornford-Nairns, R.;Daggard, G.;Mukkur, T.
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권6호
    • /
    • pp.856-865
    • /
    • 2012
  • We describe the construction and immunobiological properties of a novel whooping cough vaccine candidate, in which the aroQ gene, encoding 3-dehydroquinase, was deleted by insertional inactivation using the kanamycin resistance gene cassette and allelic exchange using a Bordetella suicide vector. The aroQ B. pertussis mutant required supplementation of media to grow but failed to grow on an unsupplemented medium. The aroQ B. pertussis mutant was undetectable in the trachea and lungs of mice at days 6 and 12 post-infection, respectively. Antigen-specific antibody isotypes IgG1 and IgG2a, were produced, and cell-mediated immunity [CMI], using interleukin-2 and interferon-gamma as indirect indicators, was induced in mice vaccinated with the aroQ B. pertussis vaccine candidate, which were substantially enhanced upon second exposure to virulent B. pertussis. Interleukin-12 was also produced in the aroQ B. pertussis-vaccinated mice. On the other hand, neither IgG2a nor CMI-indicator cytokines were produced in DTaP-vaccinated mice, although the CMI-indicator cytokines became detectable post-challenge with virulent B. pertussis. Intranasal immunization with one dose of the aroQ B. pertussis mutant protected vaccinated mice against an intranasal challenge infection, with no pathogen being detected in the lungs of immunized mice by day 7 post-challenge. B. pertussis aroQ thus constitutes a safe, non-reverting, metabolite-deficient vaccine candidate that induces both humoral and cell-mediated immune responses with potential for use as a single-dose vaccine in adolescents and adults, in the first instance, with a view to disrupting the transmission cycle of whooping cough to infants and the community.

치과위생사의 방사선 촬영업무의 확대에 대한 문헌적 고찰 (A literature review on expansion of dental hygienists' radiography operations)

  • 최영숙;김진경;장종화;박용덕
    • 한국치위생학회지
    • /
    • 제9권2호
    • /
    • pp.111-124
    • /
    • 2009
  • This study analyzes through the review of literature and laws the exposure time, clinical frequency, and radiation exposure of intraoral and extraoral radiography as well as of panoramic radiography performed by dental hygienists in dental clinics, compares the dental radiology curriculums of radiological science and dental hygiene departments, and proposes the expansion of dental hygienists' radiography operations. The radiology curriculums were compared between the radiological science and dental hygiene departments of colleges. For new analysis by radiography for dental diagnosis, the exposure time, radiation absorbed dose, effective dose, and number of days of natural radiation were compared by the type of oral radiation films and radiographical techniques proposed by domestic and international studies. The exposure time of panoramic radiography is 15 seconds and it takes about two minutes for completion, whereas the exposure time of the standard radiography is 0.2~0.8 seconds and it takes 10 times longer for completion of the radiography of full mouth than the panoramic radiography. The standard radiography can cause distortions of radiation at severely curved parts of dental arch and palatopharyngeal reflex. However, panoramic radiography can be performed even for lock jaw patients, causes less inconvenience to patients and is much simpler than the standard radiography. The percentage of dental clinics where radiography is performed by dental hygienists was 92.0%, and the percentage of standard film radiography by dental hygienists was 98% whereas the percentage of panoramic radiography by dental hygienists was 92%. For the absorbed dose which is an indicator of radiation exposure, the When the effective dose which is an indicator of the danger of radiation exposure was converted to the number of days of natural radiation, it was 3.3 days for panoramic radiography, but 13.9 days for the full mouth standard radiography by bisecting angle technique which was 4.2 times longer than the panoramic radiography. There were two colleges that had a dental radiology course with two credits in the departments of radiological science. The credits for dental radiology courses in the department of dental hygiene ranged varied by college, ranging from 3 to 8; on average, the theory course was 2.2 credits and the practice course was 2.02 credits. To summarize the above results, the percentage of dental clinics where panoramic radiography is performed by dental hygienists under the guidance of dentists is high. Panoramic radiography has become an essential facility for dental clinics. It is faster than standard film radiography and less dangerous due to low radiation exposure. Panoramic radiography is a simple mechanical job that does not require training of oral radiography by radiotechnologist. Because panoramic radiography is one of major operations which must be performed at all times in dental clinics, it must be designated as intraoral technique rather than extraoral technique, or legalized for inclusion in the scope of operations of dental hygienists.

  • PDF

MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가 (Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation)

  • 양승우;박금별;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.367-373
    • /
    • 2020
  • 물체와 X선의 상호작용로 발생하는 산란선으로 야기되는 공간 산란선량은 대부분이 저에너지 영역의 전자기파로 인체에 비교적 쉽게 흡수되어 방사선 피폭정도가 증가하게 된다. 이러한 공간 산란 선량은 방사선작업 종사자 및 환자의 방사선 피폭 정도 지표로도 사용되고 있으며 간접적으로 발생하는 공간 산란 선량을 줄여 피폭을 저감화하기 위한 방안의 필요성이 마련될 필요성이 있다. 이에 본 연구에서는 공간산란 선량을 저감화 방안으로 무납 방사선 차폐 시트를 제시하였고 가슴 X선 촬영검사를 기준으로 몬테카를로(MC; Monte Carlo) 시뮬레이션을 수행하여 거리 변화에 따른 갑상샘과 생식선 위치에서 흡수되는 산란선의 흡수선량을 산출하였고 실측치와 차폐율을 비교 평가하였다.

방사선촬영에서 면적선량 및 새로운 실질면적선량 개념의 비교 평가 (Comparative Evaluation of Kerma Area Product and New Fundamental of Kerma Area Product on Radiography)

  • 최우철;김용민;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.53-58
    • /
    • 2021
  • Kerma Area Product (KAP) is best indicator of radiation monitoring on radiographic examinations. KAP can be measured differently depending on the X-ray irradiation area, air kerma, souce-skin distance, type of equipment, etc. The major factors are exposure area and the air krema. The KAP currently used only considers the exposure area with X-rays and has a problem that KAP is always excessively overestimated from the dose received by an actual subject. Therefore, in this study, in order to measure the accurate KAP, a new area dose calculation that can be calculated by dividing the area where the actual X-ray is irradiated is presented, and the KAP is the real area. We compared and analyzed how much it was overestimated compared to the dose. The Skull AP projection and seven other projection were compared and analyzed, and the KAP was overestimated in each test by 52% to 60%. In this way, the effective KAP (EKAP) calculation developed through this study should be utilized to prevent extra calculation of the existing KAP, and only the accurate patient subject area should be calculated to derive the accurate area dose value. EKAP is helpful for control the patient's exposure dose more finely, and it is useful for the quality control of medical radiation exposure.

Disinfection Effect of Chlorine, Chlorine Dioxide end Ozone on Total Coliform in Water

  • Lee, Yoonjin;Kyoungdoo Oh;Byongho Jun;Sangho Nam
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.140-143
    • /
    • 2003
  • This research was to determine and compare the inactivation of total coliform as the indicator organism with chlorine, chlorine dioxide and ozone for drinking water treatment. The inactivation of total coliform was experimentally analyzed for the dose of disinfectant, contact time, pH, Temperature and DOC. The experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform as a general indicator organism based on chlorine, chlorine dioxide and ozone as disinfectants. The nearly 2.4, 3.0, 3.9 log inactivation of total coliform killed by injecting 1mg/L at 5 minutes for chlorine, chlorine dioxide and ozone. For the inactivation of 99.9%, Disinfectants required were 1.70, 1.00 and 0.60 mg/L for chlorine, chlorine dioxide and ozone, respectively. The bactericidal effects of disinfectants were decreased as the pH increased in the range of pH 6-9. The influence of pH change on the killing effect of chlorine dioxide was not strong, but that on ozone and free chlorine was sensitive. The bactericidal effects of the disinfectants were increased as the temperature increase. The activation energies were 36,053, 29,822, 24,906 J/mol of chlorine, chlorine dioxide, ozone for coliforms. The inactivation effects were shown in the lowest order of chlorine, chlorine dioxide and ozone.

  • PDF

성숙 및 신생마우스에서 아포프토시스를 이용한 방사선 피폭의 생물학적 지표 (Biological indicator on radiation exposure using apoptosis in adult and newborn mice)

  • 오헌;이송은;양정아;정규식;현병화;김성호
    • 대한수의학회지
    • /
    • 제38권4호
    • /
    • pp.679-685
    • /
    • 1998
  • We have studied, by a nonisotopic in situ DNA end-labeling (ISEL) technique, frequency of apoptosis in the external granular layer (EGL) of the cerebellum after whole-body irradiation of newborn mice and intestinal crypt cell of adult mice by gamma-rays from $^{60}Co$. The extent of changes following 2 Gy(10.9 Gy/min) was studied at 2, 4, 6, 8, 12, or 24h after exposure. The maximal frequency was found 4-8h after exposure. The mice that received 0.18, 0.36, 0.54, 1.08, 1.98, or 3.96 Gy were examined 6h after irradiation. Measurements performed after irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model; frequency(%) of apoptotic cell in the newborn mice cerebellum was ($13.49{\pm}1.175$)D+$(-1.52{\pm}0.334)D^2$+0.048($r^2=0.981$, D = dose in Gy) and frequency(number per crypt) of apoptotic cell in the intestinal crypt of adult mice was ($3.857{\pm}0.420$)D+$(-0.535{\pm}0.120)D^2$+0.155($r^2=0.952$, D = dose in Gy). It provides the basis required for a better understanding of results which will be obtained in any further studies for biological responses of radiation using newborn and adult mice.

  • PDF