• Title/Summary/Keyword: Dose evaluation

Search Result 1,853, Processing Time 0.024 seconds

Development of Dose Evaluation Algorithm for Film Badge Using ISO Reference Radiations (ISO 표준방사선장을 이용한 필름배지의 선량평가 알고리즘 개발)

  • Kim, Jang-Lyul;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1995
  • Since provisions on the technical criteria for personnel dosimetry was amended three years ago, several improvements in the technique of monitoring personnel doses by TLD have taken place, but for the photograpfic film as a personnel monitor, additional investigations should be carried out for its accuracy of dose estimates because of its wide use in the radiation involved industries. So, this paper describes the methods to develope dose evaluation algorithm for photographic film using ISO reference radiations by i) empirical formula, ii) degree-of-fit method, and iii) matrix approximation. These methods show a good agreement between irradiated and calculated dose within tolerance level represented in ANSI N13. 11, and can be used for the dose evaluation of X, ${\gamma}$ and/or radiation fields.

  • PDF

Repeated Dose 4-Week Oral-Treatment for DRF Toxicity Test of HMC05 in Sprague-Dawley Rats (HMC05의 Sprague-Dawley 흰쥐를 이용한 4주 반복 경구투여 DRF 독성시험)

  • Shin, Heung-Mook
    • The Journal of Korean Medicine
    • /
    • v.30 no.5
    • /
    • pp.102-114
    • /
    • 2009
  • Objectives: HMCO5 is an extract obtained from 8 different herbal mixtures. We undertook a safety evaluation of HMCO5 for a dose range finding (DRF) toxicity test in specific pathogen free (SPF) Sprague-Dawley (SD) male and female rats. Methods: The male and female rats were divided into 4 groups, respectively; G(0), treated with distilled water: G(1), treated with 222 mg/kg HMC05: G(2), treated with 667 mg/kg HMC05, and G(3), treated with 2,000 mg/kg HMC05; HMC05 was administered orally for 4 weeks. The safety evaluation examined clinical signs, mortality, body weight, food consumption, water consumption, ophthalmic findings, urinalysis, hematological values, absolute & relative organ weights, and necropsy findings during the tests. Results: There were no changes in clinical signs, mortality, body weight, food consumption, water consumption, and ophthalmic findings examined during the test periods. In serum biochemical values, triglyceride was increased in male group G(3) and Na$^+$ decreased significantly in male groups G(2), G(3) and G(4). In male group G(4), spleen weight decreased relatively and increases of absolute & relative left ovary weights were found. In addition, an adhesion of liver to diaphragm was found in male group G(2). However, we could not find any dose-interrelationships in these changes. Conclusions: These results indicate that HMC05 extract did not show any toxicity in the DRF toxicity study. Therefore, it suggests that establishment of 1,000, 333 and 111 mg/kg dosages are moderate in a repeated dose 26-week oral toxicity study of HMC05.

  • PDF

Assessment of Thyroid Dose Evaluation Method by Monitoring of I-131 Concentration in Air (공기중 I-131 농도 감시에 의한 갑상선 피폭 평가법의 적용성)

  • Lee, Jong-Il;Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.69-80
    • /
    • 1994
  • The TCMI(Three-Compartment Model for iodine) computer code has been developed, which is based on the three-compartment model and the respiratory model recommended in ICRP publication 54. This code is able to evaluate the thyroid burden, dose equivalent, committed dose equivalent and urinary excretion rate as time-dependent functions from the input data: working time and the radioiodine concentration in air. Using the TCMI code, the time-dependent thyroid burdens, the thyroid doses and the urinary excretion rates were calculated for three specific exposure patterns : acute, chronic and periodic. Applicability as an internal dose evaluation method has been assessed by comparing the results with some operational experiences. Simple equations and tables are provided to be used in the evaluation of the thyroid burden and the resulting doses for given I-131 concentration in air and the working time.

  • PDF

흉부의 ANALOG-DIGITAL 영상에 대한 비교 평가

  • Jang, Yeong-Ae;Mun, Hui-Seok;Im, Han-Yeong;O, Hyeon-Ju;Kim, Seong-Su;Kim, Yeong-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.2 no.1
    • /
    • pp.74-82
    • /
    • 1996
  • This paper were studied the evaluation in compare with the conventional and AMBER of analog images, PACS and CR of digital images which were collected every ten sampling chest images with the J.J.Vucicuh chest evaluated chart, and were measured the chest phantom surface dose and the density of several part in chest images. The evaluated numbers were total 22 persons who were 6 persons of the M.D., 6 of the radiotechnological professors and 10 of the radiotechnologists. The obtained results summarized as following : 1. Approaching the optimum standard density of the several part in chest images drew near at the lung round region density in PACS images, the sternum region density in CR and AMBER images, the heart region density in CR AMBER images, the diaphram region density in AMBER and conventional images. 2. The evaluation measured surface dose were appeared orderly lesser dose at the AMBER images (spine 21 mR, lung 2mR, heart 12mR, apex 6mR) than the conventional images(32 mR), CR images(38mR) and PACS images(81mR). 3. The anatomical physical evaluation marks were taken the highest points at CR images(88.3), and orderly PACS images(82), AMBER images(79.2) and conventional images(65.2). 4. It is exposured with lesser surface dose at the analog images, but analog images leaves much room for image quality improvement, and digital images demand for lesser exposure surface dose, although excellent image quality.

  • PDF

Evaluation of Image Quality and Radiation Dose for Filtered Back-Projection and Iterative Reconstruction Algorithm in Abdominal Computed Tomography Protocol (복부 CT 프로토콜에서 필터 보정 역투영법과 반복적 재구성기법에 따른 화질 및 선량에 관한 연구)

  • Oh, Jeong-Min;Seo, Hyeon-Ji;Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1065-1072
    • /
    • 2021
  • In Computed Tomography, abdominal examination showed the highest proportion of use, and effort of reducing the radiation dose is required. Recently introduced Iterative Reconstruction(IR) is repetitive reconstruction technique of Computed Tomography. SIEMENS' IR, ADMIRE and GE's IR, ASIR-V, were used in this examination. Noise, % Contrast, and High contrast resolution were measured by using ACR phantom for image quality evaluation. In addition, CTDIvol and DLP displayed in the CT device were used for dose evaluation. When FBP and IR were compared, stage 2 to stage 5 of ADMIRE and 10, 30, 50, 70, and 90% of ASIR-V were applied, noise could be reduced from a minimum of 0.46 to a maximum of 2.38 in ADMIRE compared to FBP, and noise from a minimum of 0.51 to a maximum of 2.5 in ASIR-V compared to FBP. Also, % Contrast and High contrast resolution of FBP and IR were no statistical difference. When IR was used for abdominal CT examination, the radiation dose of ADMIRE is reduced by 25.39% compared to the radiation dose of FBP. Also, the radiation dose of ASIR-V is reduced by 16.61% compared to the radiation dose of FBP. In conclusion, it is believed that if IR is applied during abdominal CT examination, the radiation dose can be reduced without deteriorating the image quality.

External dose assessment for workers dismantling the bio-shield of a commercial power nuclear reactor: Case study of Kori-1, Korea

  • Lee, ChoongWie;Lee, Donghyun;Kim, Hee Reyoung;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2085-2091
    • /
    • 2020
  • The license for Kori-1, the first commercial reactor in Busan, Korea, was terminated in June 2017; therefore, preparations are being made for its decommissioning. Because the radioactivity of Bio-shield varies greatly throughout the structure, the doses received by the workers depend on the location, order, and duration of dismantling operations. Thus, a model for evaluating the worker external dose during the dismantling of the Kori-1 bio-shield was developed, and work scenarios for dose assessment were designed. The Dose evaluation code VISIPLAN was used for dose assessment. The dose rate around the bio-shield was evaluated and the level of exposure to the operator was evaluated according to the work scenario. The maximum annual external dose was calculated as 746.86 mSv for a diamond wire saw operator under dry cutting conditions, indicating that appropriate protective measures, such as changing dismantling sequence, remote monitoring, shield installation, and adjustment of work team are necessary for the safe dismantling of the bio-shield. Through these protective measures, it was found that the worker's dose could be below the dose limit.

Evaluation of Radiation Doses of Dental Portable Equipment (치과용 이동형 방사선장치의 선량평가)

  • Park, Hoon-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

Inhalation Toxicity Study of H Menthol (Nicotine Free-Tobacco Free) Herbal Cigarettes (H Menthol (Nicotine Free-Tobacco Free) Herbal Cigarette의 흡입독성시험)

  • 강경선;조성대;조종호;김경배;이지해;안남식;정지원;양세란;박준석
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • Nowadays a huge variety of products that aim to assist to quit smoking or reduce addictive symptoms are developed and manufactured with safety evaluation, but the safety of the most recent products of interest which do not contain tobacco and nicotine, and shape cigarettes is not evaluated and guaranteed relatively. This study was carried out to evaluate the single and repeated dose inhalation toxicity and genotoxicity of H menthol (Nicotine free-tobacco free) herbal cigarettes provided by Cigastop Ltd. in ICR mice. In this study, doses which we determined to expose to mice were 40 cigarettes for 6 hours a day to mice in single dose and 20 (high dose), 10 (middle dose) and 5 cigarettes (low dose) a day for 28 days in repeated dose inhalation toxicity, in vivo chromosome aberration test and micronucleus test. The particulate substances from H menthol herbal cigarettes also were gathered and used in the Salmonella typhimurium/microsome assay (Salmonella test; Ames test). We could find neither significant changes between control and treatment groups nor dose-response effects of test material at all except serum Ca level of female middle dose treatment group in repeated dose inhalation toxicity test. In conclusion, H menthol herbal cigarettes, when applied clinically intended dose we used, might not show any toxic and/or mutagenic effect.

  • PDF

Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions (심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가)

  • Seong-Bhin Koh;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

Evaluation of Radiation Dose and Image Quality according to CT Table Height (CT 테이블 높이에 따른 방사선 선량 및 화질 평가)

  • Lee, Jongwoong;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.453-458
    • /
    • 2017
  • Computed Tomography (CT) provides information on the Diagnostic Reference Level Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP) for accurate diagnosis of patients. However, it does not provide a dose change according to the table height for the diagnostic reference level provided by the CT equipment. The purpose of this study was to evaluate the image and dose according to the table height change using phantom (PMMA: Polymethyl Methacrylate) in order to find the optimal image and the minimum dose during computed tomography examination. When examining using a 32 cm PMMA phantom with the same thickness as the abdomen of an adult, there was little change in dose with table height. However, the noise evaluation of the image caused a high fluctuation of noise depending on the table height. and in the case of the 16 cm PMMA phantom, the change of the noise was small, but the dose change was about 30%. In conclusion, the location of the patient and the center of the detector are important during computed tomography (CT) examinations. In addition, table height setting is considered to be important for examinations with optimized image and minimum dose.