• Title/Summary/Keyword: Dose enhancement

Search Result 296, Processing Time 0.02 seconds

Effects of Squalene on the Immune Responses in Mice(II):Cellular and Non-specific Immune Response and Antitumor Activity of Squalene

  • Ahn, Young-Keun;Kim, Joung-Hoon
    • Archives of Pharmacal Research
    • /
    • v.15 no.1
    • /
    • pp.20-29
    • /
    • 1992
  • Effects of squalene on cellular and non-specific immune responses and antitumor activity in mice were investigated. Cellular and non-specific immunological assay parameters adopted in the present study were delayed-type hypersensitivity reaction and resette forming cells (RFC) for cellular immunity, activities of natural killer (NK) cells and phagocyte for non-specific immunity. Squalene resulted in marked increases of cellular and non-specific immune functions and enhancement of host resistance to tumor challenge in dose-dependent manner.

  • PDF

Augmentation of Macrophage Cytotoxicity and NO Production by Pedunculagin (Pedunculagin의 Macrophage에 대한 항암활성 및 Nitric Oxide 생성)

  • 이도익;김형근;이민원;최영욱;김하형;김은주
    • YAKHAK HOEJI
    • /
    • v.44 no.2
    • /
    • pp.175-181
    • /
    • 2000
  • Pedunculagin is an ellagitannin purified from Alnus hirsuta var. microphylla, Betulaceae. The effects of pedunculagin on the immune system have been characterized to induce enhancement of NK (natural killer) cell cytotoxicities against tumor cells. The present study investigated whether pedunculagin can enhance macrophage cytotoxicity against P8l5 tumor cells. Macrophage cultured with pedunculagin enhanced cytotoxicity in a dose dependent manner In addition, the same treatments increased NO production, which plays important roles in the immune system. liken together these results demonstrate that pedunculagin significantly enhances cytolytic activities of macrophage.

  • PDF

Development of the EGS4 Control Code to Calculate the Dose Distributions in a Strong Magnetic Field (자기장이 인가된 물팬텀 속의 전자선 선량분포 계산을 위한 EGS4 제어코드의 개발과 응용)

  • 정동혁;오영기;신교철;김진기;김기환;김정기;이강규;문성록;김성규
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • In this work we developed a EGS4 control code to calculate the dose distributions for high energy electron beams in water phantom applied longitudinal magnetic field. We reviewed the electron's motion in magnetic field and delivered equations for direction changs of the electron by the external magnetic field. The mathematical results are inserted into the EGS4 code system to account for the presence of external magnetic fields in phantom. The electron pencil beam paths of 6 MeV in water phantom are calculated for magnetic fields of 1-3 T and the dose distributions for a field of 1.0 cm in diameter are calculated for magnetic fields of 0.6-1 T using the code. From the results of path calculations we found that the lateral ranges of the electrons are reduced in the magnetic field of 3 T. For a field of 1 cm diameter and a magnetic field of 1 T, the small dose enhancement near the range of the electrons on the depth dose and the penumbra reduction of 0.15 cm on the beam profile are observed. We discussed and evaluated the results from the theoretical concepts.

  • PDF

Effects of electron beam irradiation on the superconducting properties of YBCO thin films

  • Lee, Y.J.;Choi, J.H.;Jun, B.H.;Joo, J.;Kim, C.S.;Kim, C.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.4
    • /
    • pp.15-20
    • /
    • 2016
  • The effects of electron beam (EB) irradiation on the superconducting critical temperature ($T_c$) and critical current density ($J_c$) of YBCO films were studied. The YBCO thin films were irradiated using a KAERI EB accelerator with an energy of 0.2 MeV and a dose of $10^{15}-10^{16}e/cm^2$. A small $T_c$ decrease and a broad superconducting transition were observed as the EB dose increased. The value of $J_cs$ (at 20 K, 50 K and 70 K) increased at doses of $7.5{\times}10^{15}$ and $2.2{\times}10^{16}e/cm^2$. However, $J_cs$ decreased as the dose increased further. The X-ray diffraction (XRD) analysis showed that the c axis of YBCO was elongated and the full width at half maximum (FWHM) increased as the dose increased, which is strong evidence of the atomic displacement by EB irradiation. The transmission electron microscopy (TEM) showed that the amorphous layer formed in the vicinity of the surfaces of the irradiated films. The amorphous phase was often present as an isolated form in the interior of the films. In addition to the formation of the amorphous phase, many striations running along the a-b direction of YBCO were observed. The high magnification lattice image showed that the striations were stacking faults. The enhancement of $J_c$ by EB irradiation is likely to be due to the lattice distortion and the formation of defects such as vacancies and stacking faults. The decrease in $J_c$ at a high EB dose is attributed to the extension of the amorphous region of a non-superconducting phase.

Studies on the Cardiovascular Effects of Ambrein Pretreatment in Rats

  • Raza, M.;Taha, S.A.;El-Khawad, I.E.
    • Natural Product Sciences
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 1999
  • The pharmacological actions of ambrein were investigated alone or in combination as a pretreatment with agonists (adrenaline, noradrenaline, acetylcholine, histamine, nicotine), antagonists (atropine, atenolol) and calcium channel blocker (verapamil) in vivo in anaesthetized SWR rats using blood pressure, heart rate and myocardial contractility as parameters. Ambrein in the dose range of 50-200 mg/kg to the normotensive anaesthetized rats demonstrated negative chronotropic effect and increased the myocardial contractility significantly. At the mid dose (100 mg/kg) this increase in contractile force was 36% and 44% above the normal at 30 min and 60 min intervals post-treatment, respectively. Both of the lower and high doses (50 mg/kg and 200 mg/kg) had similar effects. Furthermore, this contractile response was dose related. Also, this compound produced a considerable increase in myocardial contractility when used as a pretreatment with some agonists and antagonists. The results on blood pressure did not show a considerable change when ambrein was used alone. However, ambrein pretreatment at the dose of 100 mg/kg did not block the effects of adrenaline, noradrenaline, isoprenaline and acetylcholine on heart rate and blood pressure. On the other hand, this pretreatment attenuated the sympathoadrenal effects of nicotine significantly. Chronotropic and blood pressure changes produced by histamine were also inhibited by ambrein pretreatment. This pretreatment significantly reversed the effects of atenolol but failed to demonstrate any change in the negative chronotropic, inotropic and hypotensive responses induced by verapamil. It is concluded that ambrein induced nonselective dose dependent antagonism of the effects of some agonists and antagonists require contribution of some neuromediators. However, the positive isotropic effects of ambrein possibly involve the enhancement of slow Ca channels and/or activation of ${\beta}-adrenergic$ receptors in the heart. At this moment it is difficult to explain the exact mode of action of ambrein and the studies dealing with Ca channel blocker and adrenergic blocker followed by ambrein may help to define the factors which contribute to its positive inotropic effects.

  • PDF

Effect of Low Dose of Gamma Radiation on the Growth of Groundnut (Arachis hypogaea L.) (저선량 감마선이 땅콩 생장에 미치는 효과)

  • 김재성;이은경;백명화;박홍숙;김광호
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.3
    • /
    • pp.257-261
    • /
    • 1999
  • Effect of low dose gamma radiation on the growth of groundnut (Arachis hypognea L.) were investigated with respect to germination rate, seedling development and yield. Seeds of “Palpal” cultivar were irradiated with 0.5~20 Gy of ${\gamma}$ radiation in order to determine the hermetic effect of low dose radiation. The germination rate of ${\gamma}$-ray irradiation group was lower than that of the control but the seedling height of groundnut grown from seeds irradiated with low dose ${\gamma}$-ray was slightly higher than that of the control. The number of pod and kernels, and the seed yield increased by 27%, 17% and 19 %, respectively, in the 12.0 Gy irradiation group compared to that in the control group. The 100 seed weight was 87.2 g in the 4.0 Gy irradiation group, which was 11% heavier than 78.3 g in the control group. Low dose radiation showed an enhancement effects on the growth and yield components of groundnut.

  • PDF

Immunobiological Studies on Doses of Methanol Extract of Astragali Radix (황기의 메탄올 추출물의 용량에 따른 면역생물학적 연구)

  • Kim, Joung-Hoon;Park, Joung-Suk;Chae, Byeong-Suk;Kang, Tae-Wook;Park, Chan-Bong;Ahn, Young-Keun
    • YAKHAK HOEJI
    • /
    • v.40 no.3
    • /
    • pp.326-334
    • /
    • 1996
  • Effects of methanol extract of Astragali Radix (AR) on the immune responses were studied using ICR mice. Mice were divided into 4 groups (10mice/group), and methanol extracts of AR at doses of 0.05, 0.25 and 1.25g/kg were orally administered to ICR mice once a day for 2 weeks. Mice were immunized and challenged with sheep red blood cells (SRBC). The results of this study were summarized as follows; (1) Methanol extract of AR at 0.05, 0.25 and 1.25g/kg didn't affect the weight ratios of thymus to body, as compared with those in controls, but significantly increased spleen weight ratio. (2)Methanol extract of AR at 0.05 and 0.25g/kg significantly increased hemagglutination titer and splenic plaque forming cells corresponding to humoral immunity, as compared with those in controls, but their enhancements were somewhat lowered at a high dose (1.25g/kg). (3) Methanol extract of AR at 0.05 and 0.25g/kg siginificantly increased delayed-type hypersensitivity reaction resulted from cell-mediated immunity, as compared with those in controls, but not so significant increases were observed at a high dose (1.25g/kg). (4) Methanol extract of AR at 0.05 and 0.25g/kg significantly increased phagocytic activity and the number of circulating leukocyte compared with those in controls, but their enhancements were lowered at a high dose (1.25g/kg). These results suggest that methanol extract of Astragali Radix increased humoral and cell-mediated immune responses, phagocytic activity and the number of circulating leukocyte, dependent upon dose, but inhibited their enhancement effects were decreased at a high dose (1.25g/kg).

  • PDF

A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes

  • Cho, Jae-Hun;Kim, Jae-Yun;Kang, Joo-Eun;Park, Pyong-Eun;Kim, Jae-Hun;Lim, Jeong-Ae;Kim, Hae-Kyoung;Woo, Nam-Sik
    • The Korean Journal of Pain
    • /
    • v.24 no.4
    • /
    • pp.199-204
    • /
    • 2011
  • Background: Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods: We measured the RADs in the C-arm fluoroscopic modes including 'conventional mode', 'pulsed mode', 'low-dose mode', and 'pulsed + low-dose mode'. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results: Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions: The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians.

The Enhancement of Skin Sparing by Tray Materials for High Energy Photon Beam (고에너지 광자선치료에서 고정판 흡수물질을 이용한 피부보호효과의 향상)

  • Chu, Sung-Sil;Lee, Chang-Geol;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 1993
  • The skin sparing effect associated with high energy x-ray or gamma ray beams may be reduce or lost under certain conditions of treatment. Current trends in using large fields. Shield carrying trays, compensating filters, and isocentric methods of treatment have posed problems of increased skin dose which sometimes become a limiting factor in giving adquate tumor doses. We used the shallow ion chamber to measure the phantom surface dose and the physical treatment variables for Co-60 gamma ray, 4MV and 10 MV x-ray beam. The dependence of percent surface dose on field sizes, atomic number of the shielding tray materials and its distance from the surface for 4, 10MV x-rays and Co-60 gamma ray is qualitatively similar. The use of 2 mm thick tin filter is recommended for situations where a low atomic number tray is introduced into the beam at distances less than 15 cm from the surface and with the large field sized for 4 MV x-ray beam. In case of Co-60 gamma ray, the lead glass tray is suitable for enhancement of skin sparing. Also, the filter distance should be as large as possible to achieve substantial skin sparing.

  • PDF

The Use of Contrast-Enhanced Color Doppler Ultrasound in the Differentiation of Retinal Detachment from Vitreous Membrane

  • Sang-Suk Han;Seung-Kook Chang;Jung-Hee Yoon;Young-Joon Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • Objective: To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. Materials and Methods: In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Results: Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Conclusion: Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD.

  • PDF