Change of PET Image According to CT Exposure Conditions (CT 촬영 조건에 따른 PET 영상의 변화)

  • Park, Jae-Yoon;Kim, Jung-hoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.473-479
    • /
    • 2019
  • PET-CT improves performance and reduces the time by combining PET and CT of spatial resolution, and uses CT scan for attenuation correction. This study analyzed PET image evaluation. The condition of the tube voltage and current of CT will be changed using. Uniformity phantom and resolution phantom were injected with 37 MBq $^{18}F$ (fluorine ; 511 keV, half life - 109.7 min), respectively. PET-CT (Biograph, siemens, US) was used to perform emission scan (30 min) and penetration scan. And then the collected image data were reconstructed in OSEM-3D. The same ROI was set on the image data with a analyzer (Vinci 2.54, Germany) and profile was used to analyze and compare spatial resolution and image quality through FWHM and SI. Analyzing profile with pre-defined ROI in each phantom, PET image was not influenced by the change of tube voltage or exposure dose. However, CT image was influenced by tube voltage, but not by exposure dose. When tube voltage was fixed and exposure dose changed, exposure dose changed too, increasing dose value. When exposure dose was fixed at 150 mA and tube voltage was varied, the result was 10.56, 24.6 and 35.61 mGy in each variables (in resolution phantom). In this study, attenuation image showed no significant difference when exposure dose was changed. However, when exposure dose increased, the amount of dose that patient absorbed increased too, which indicates that CT exposure dose should be decreased to minimum to lower the exposure dose that patient absorbs. Therefore future study needs to discuss the conditions that could minimize exposure dose that gets absorbed by patient during PET-CT scan.

Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source (Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자에너지 플루언스와 질량에너지흡수계수 유도)

  • Kim, Jong-Eon;Ahn, Il-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.61-66
    • /
    • 2022
  • The purpose of this study is to derive photon energy fluence and mass energy absorption coefficient for 1 Gy of absorbed dose of water in brachytherapy using an Ir192 source. From the radiotherapy physics written by Khan, the half-value of lead for the gamma ray beam of the Ir192 source was obtained. The linear attenuation coefficient and the mass attenuation coefficient were calculated from the obtained half-value layer of lead. By matching the calculated lead mass attenuation coefficient with the NIST mass attenuation coefficient data, the photon energy of the matching mass attenuation coefficient was determined as the effective energy. By matching the determined effective energy with the photon energy of the NIST data on the mass energy absorption coefficient of water, the mass energy absorption coefficient of water was obtained as 0.03273 cm2/g(32.73 cm2/kg). The photon energy fluence was calculated as 0.03055 J/cm2 by dividing the obtained mass energy absorption coefficient (32.73 cm2/kg) by the absorbed dose of water 1 Gy.

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF

A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis (노발리스를 이용한 방사선 수술시 치료테이블을 투과하는 광자선의 감쇠율에 따른 선량 보정방법)

  • Kim, Sung-Joon;Shin, Hyun-Soo;Ko, Seung-Young;Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Yea, Ji-Woon;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.12-17
    • /
    • 2011
  • This study has its own goal to deliver the accurate dose on the target volume by calculating and modifying the attenuation rate of photon beam transmitting the couch top with geometric model. The experiment was that the transmission rate and attenuation rate of photon beam transmitting the couch top was predicted by the geometric model, then compared and analyzed with what was measured experimentally based on that. The result showed that the predicted value by the geometric model accorded closely with the experimental value. In addition, in order to judge whether the practical clinical application is available, the point dose, measured after modifying the attenuation rate modelinged according to the treatment plan of a patient of spine radiosurgery, was compared with the one done nothing. The result was that the former showed decreased error range with treatment planned one than the latter. This papers calculated the transmission and attenuation rate with the geometric model transmitting the couch top and verified it experimentally. This method is expected to be very useful in not only the radiosurgery using Novalis but also the general radiation therapy.

Effect of Saline Flush on the Enhancement of Vascular and Liver via Saphenous Vein for Abdominal CT in Dogs

  • Kim, Song Yeon;Hwang, Tae Sung;An, Soyon;Hwang, Gunha;Go, Woohyun;Lee, Jong Bong;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.135-142
    • /
    • 2021
  • The aim of this study was to evaluate the contrast effect if a saline flush following low-volume contrast medium bolus improves vascular and parenchymal enhancement using a saphenous vein in abdominal CT for small animals. Six clinically healthy beagle dogs underwent abdominal contrast-enhanced CT. They were divided into nine groups (each group, n = 6), according to the volume of contrast medium 1, 2, and 3 mL/kg, and volume of the saline solution 0, 5, and 10 mL. Dynamic CT scanning was performed at the hepatic hilum level. The maximum contrast enhancement, time to maximum enhancement, and time to equilibrium phase were calculated from the time attenuation curves. Mean attenuation values for all groups were measured in the aorta, portal vein, and liver. After contrast enhancement, grading of image quality regarding surrounding artifacts and evaluation of the hepatic hilum structures was performed. For comparison of the effect of the contrast material and saline solution doses, differences in mean attenuation values between the contrast medium 2 mL/kg without saline flush group and the remaining groups, and between contrast medium 3 mL/kg without saline flush group and the remaining groups, were analyzed for statistical significance. There were no significant differences between with and without saline flushing at the same contrast medium dose groups. There were no significant differences in peak values between the 3 mL/kg dose of contrast medium alone and the 2 mL/kg dose of contrast medium with saline solution flush. However, there was a significant difference in peak values between the 3 mL/kg dose of the contrast medium without the saline flush group and the 2 mL/kg dose of the contrast medium alone group. Grades of the artifacts were not significantly different in the saline flush regardless of the dose of the contrast medium. Using 2 mL/kg of contrast medium with saline solution flush resulted in similar liver parenchyma attenuation, compared with using 3 mL/kg of contrast medium without saline solution flush. In CT evaluation of hepatic parenchymal diseases, using 2 mL/kg of contrast medium with saline solution flush may yield decreased risk of contrast nephropathy and cost-saving.

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

Dose and Image Quality Analysis According to The Type of Composite Additional Filter (복합 부가필터 종류에 따른 선량 및 화질 분석)

  • Myoung, Noh-Beom;Im, So-Yeon;Yoo, Se-Jong;Kim, Seong-Ho;Jeon, Min-Cheol
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.147-154
    • /
    • 2020
  • In this study, four types of composite added filtration (aluminum, nickel, copper, and zinc) were combined for each thickness to evaluate dose reduction and optimal images due to X-ray attenuation. To evaluate dose and image quality. X-ray generators, Dose Area Product(DAP) and ICY programs with RQR9 standard quality were used. In the image quality evaluation element (PSNR, RMSE, SSIM), only images with PSNR value of 30 dB or more were analyzed. As a result, the best combination in dose evaluation was 3 mmAl + 0.6 mmNi (0.16µGy㎡), and the best filter in image quality evaluation was 0.9 mmAl (PSNR 34.24dB, RMSE 79.52, SSIM 0.24). In this study, the dose aspect and the image quality aspect are mentioned, So it is considered that further studies on patient's exposure dose and optimal image will be needed in the future.

전신방사선조사(TBI)시 다이오드측정기(Diode detector) 및 열형광선량계(TLD)를 이용하여 측정한 골조직 선량감쇠에 대한 고찰

  • 임현실;이정진;장인기;김완선
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.6-11
    • /
    • 2003
  • 목적 : 전신방사선조사(TBI)시 균등한 선량을 조사할 목적으로 사용되는 각 신체부위별 보상체(compensator) 두께의 결정은 열형광선량계(TLD)를 이용하여 표면선량(surface dose)을 측정하고, 심부선량(depth dose)으로 환산하는 방법을 주로 이용한다. 그러나 이와 같은 방법은 골(bone) 조직에 대한 선량감쇠(dose attenuation)의 영향이 고려되지 않아 신체중심부에서의 정확한 심부선량을 알 수가 없다. 이에 본 연구

  • PDF

Scatter Dose in soft tissue using the partial attenuation filter for 6 MV X-ray of linear accelerator (6 MV 광자선조사면내 투과성필터에 의한 조직선량)

  • 최태진;김옥배
    • Progress in Medical Physics
    • /
    • v.4 no.1
    • /
    • pp.55-71
    • /
    • 1993
  • Measured and calculated the TMR and SMR factors from percent depth dose underpartial attenuators which cover the whole part of the radiation beam with variousfilter thickness from 0 to 50 mm. This study was performed for x-ray beams generated with a 6 MV linear acceleratorat source to surface distance of 100cm in a water phantom for Lipowitz metal. TMR(0,d,t) was derived from non-linear polynomial regression with field sizedifferencies and a given filter thickness. In this experiments, the TMR(0,10,50) of 50mm of filter thickness was showed13.6 % higher than that of open field and SMR(5,10,50) was 38.5% smaller than thatof open field in same depth.

  • PDF