• Title/Summary/Keyword: Dose assessment procedure

Search Result 31, Processing Time 0.028 seconds

Gross Alpha Analysis of Nasal Smear Samples and Internal Dose Assessment Procedure in Radiation Emergency (방사선비상시 비강스메어 시료의 전알파 분석 및 내부피폭선량평가 절차)

  • Yoon, Seokwon;Ha, Wi-Ho;Kim, Mee-Ryeong;Lee, Seung-Sook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.226-230
    • /
    • 2012
  • The gross alpha analysis of nasal smear samples for the radiation emergency and the additional follow-up steps were established. Cotton swab sticks using in local hospitals for nasal smear in Korea were used for the verification. The measurement results of standard samples spiked with certified reference source were well agreed within ${\pm}20%$ compared with reference values. The clearance ratio of smear samples conducted with wet smear condition showed higher value. To eliminate the quenching effect of liquid scintillation samples, dry of smear samples should be followed up before counting samples. Based on the measurement results, medical decision levels and internal dose assessment were established for the victims in the beginning of radiation emergency.

A Computed Tomography Analysis of the Success of Spinal Fusion Using Ultra-Low Dose (0.7 mg per Facet) of Recombinant Human Bone Morphogenetic Protein 2 in Multilevel Adult Degenerative Spinal Deformity Surgery

  • Liu, Gabriel;Tan, Jun Hao;Yang, Changwei;Ruiz, John;Wong, Hee-Kit
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1010-1016
    • /
    • 2018
  • Study Design: Retrospective cohort study. Purpose: To report on spinal fusion assessment using computed tomography (CT) after adult spinal deformity (ASD) surgery using ultra-low dose recombinant human bone morphogenetic protein 2 (RhBMP-2). Overview of Literature: The reported dose of RhBMP-2 needed for successful spinal posterolateral fusion in ASD ranges from 10 to 20 mg per spinal level. This study reports the use of ultra-low dose of RhBMP-2 (0.07 mg per facet) to achieve spinal fusion in multilevel ASD surgery. Methods: Consecutive patients who underwent ASD surgery using ultra-low dose RhBMP-2 were recruited. Routine postoperative CT analysis for spinal fusion was performed by two spine surgeons. Inter-observer agreement was calculated for facet fusion (FF) and interbody fusion (IBF) at 6 and 12 months after the procedure. Results: Six consecutive ASD patients with a mean age of 62 years (28-72 years) were examined. Each patient received a total dose of 12 mg with an average dose of $0.69{\pm}0.2mg$ (0.42-1 mg) per single FF and $1.38{\pm}0.44mg$ (0.85-2 mg) for IBF. Total 131 FF and 15 IBF were examined in the study, with 88 FFs and nine IBFs being analyzed specifically at 6 months after the surgery. FF and IBF reported by surgeons A and B at 6 months were 97.7% vs. 91.9% FF, respectively (${\kappa}=0.95$) and 100% vs. 100% IBF, respectively (${\kappa}=1$). Two patients underwent longitudinal follow-up CT at 12 months, and the FF rates reported by surgeons A and B were 100% vs. 95.8%, respectively (${\kappa}=0.96$). Five out of nine facet (56%) non-unions were identified at the cross-links. The remaining four facet pseudarthrosis were noted at 1-2 spinal levels caudal to the cross-links. At the final clinical follow-up, there was no rod breakage, deformity progression, neurological deficit, or symptom recurrence. The Oswestry Disability Index improved by an average of $32.8{\pm}6.3$, while the mental component summary of the 36-item Short-Form Health Survey improved by an average of $4.7{\pm}2.1$, and physical component summary improved by an average of $10.5{\pm}2.1$. Conclusions: To our knowledge, this is the first study to report a CT that defined 92%-98% FF and 100% IBF using the lowest reported dose of RhBMP-2 in multilevel ASD surgery. The use of ultra-low dose RhBMP-2 reduces the RhBMP-2 related complications and healthcare costs.

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Optimal effective-site concentration of remifentanil for sedation during plate removal of maxilla

  • Park, Jeong-Hoon;Yoon, Ji-Young;Kim, Eun-Jung;Yoon, Ji-Uk;Choi, Byung-Moon;Ahn, Ji-Hye
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.5
    • /
    • pp.295-300
    • /
    • 2018
  • Background: Removal of the plate following Le Fort I osteotomy and BSSO (bilateral sagittal split osteotomy) is a common procedure. However, patients who undergo plate removal experience intense pain and discomfort. This study investigated the half-maximal effective concentration ($Ce_{50}$) of remifentanil in the prevention of plate removal pain under sedation using dexmedetomidine. Methods: The study evaluated 18 patients, between 18 and 35 years of age, scheduled for elective surgery. Remifentanil infusion was initiated after sedation using dexmedetomidine, and started at a dose of 1.5 ng/mL on the first patient via target-controlled infusion (TCI). Patients received a loading dose of $1.0{\mu}g/kg$ dexmedetomidine over 10 min, followed by a maintenance dose of $0.7{\mu}g/kg/h$. When the surgeon removed the plate, the patient Modified Observer's Assessment of Alertness/Sedation (MOAA/S) score was observed. Results: The Ce of remifentanil ranged from 0.9 to 2.1 ng/mL for the patients evaluated. The estimated effect-site concentrations of remifentanil associated with a 50% and 95% probability of reaching MOAA/S score of 3 were 1.28 and 2.51 ng/mL, respectively. Conclusion: Plate removal of maxilla can be successfully performed without any pain or adverse effects by using the optimal remifentanil effect-site concentration ($Ce_{50}$, 1.28 ng/mL; $Ce_{95}$, 2.51 ng/mL) combined with sedation using dexmedetomidine.

A stuffy on the environmental Impact Assessment of golf course development - A comparative cross - cultural analysis between Korea and Japan (골프장 개발에 따른 환경영향평가에 관한 연구 -한국과 일본의 문화적 비교 분석-)

  • ;Tsunekawa Atsushi,;Hayashi kuniyoshi
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.18 no.2
    • /
    • pp.1-13
    • /
    • 1990
  • In recent years, the construction of golf course has been increasing very rapidIy and serious concern is paid to its environmental consequences both in Korea and in Japan. EIA systems as a major requirements for golf course developments emerged to reduce the adverse impact of their developments in Korea as well as in Japan. This study aims to compare EIA systems, procedures and methodologies employed between Korea and Japan in order to demonstrate the success and failure of EIAs in each country. The results of this study can be summarized as follows : 1) EIAs are systematically undertaken based upon law in Korea but on regulation in Japan. 2) Public participation Isn't encouraged in the Korean EIA procedure while the Japan EIA system involves public participation. 3) Korean EISs shall be prepared after the proposed projects are approved according to the related laws and be followed by the necessary procedures, but in the carte of Japan, EISs be prepared prior to their approval . 4) ELSs shall be prepared by agencies with special expertise with respect to 7he environmental impacts (appointed by government) or the sponsoring agencies themselves in Korea whereas they be prepared by agencies proposing the projects in japan. 5) EISs both in Korea and in Japan are characterized by cliches which may be unfamiliar to reviews and the public. 6) EIAs describe the existing presence and predict and evaluate that a development work influences the present conditions. Here Japan EIA treats mainly natural - and life environment, whereas Korean EIA dose social - and economic environment. And hence in the case of Japan is undertaken more quantitative and scientific analysis, whereas in the case of Korea is less. It is suggested that the key point to impact analysis is to use the correct concepts, fomulate the comparative studies of methodologies and find the methods that suit the decision as well as which country's own circumstances.

  • PDF

Estimation of an Occupational Exposure Limit for Multi-Walled Carbon Nanotubes Manufactured in Korea (국내 일부 다중벽탄소나노튜브의 직업노출기준 추정)

  • Kim, Jong Bum;Kim, Kyung Hwan;Choi, Byung-Gil;Song, Kyung Seuk;Bae, Gwi-Nam
    • Journal of Environmental Science International
    • /
    • v.25 no.4
    • /
    • pp.505-516
    • /
    • 2016
  • With the development of nanotechnology, nanomaterials are used in various fields. Therefore, the interest regarding the safety of nanomaterial use is increasing and much effort is diverted toward establishment of exposure assessment and management methods. Occupational exposure limits (OELs) are effectively used to protect the health of workers in various industrial workplaces. This study aimed to propose an OEL for domestic multi-walled carbon nanotubes (MWCNTs) based on animal inhalation toxicity test. Basic procedure for development of OELs was examined. For OEL estimation, epidemiological study and quantitative risk assessment are generally performed based on toxicity data. In addition, inhalation toxicity data-based no observed adverse effect level (NOAEL) and benchmark dose (BMD) are estimated to obtain the OEL. Three different estimation processes (NEDO in Japan, NIOSH in USA, and Baytubes in Germany) of OELs for carbon nanotubes (CNTs) were intensively reviewed. From the rat inhalation toxicity test for MWCNTs manufactured in Korea, a NOAEL of $0.98mg/m^3$ was derived. Using the simple equation for estimation of OEL suggested by NEDO, the OEL of $142{\mu}g/m^3$ was estimated for the MWCNT manufacturing workplace. Here, we used test rat and Korean human data and adopted 36 as an uncertainty factor. The OEL for MWCNT estimated in this work is higher than those ($2-80{\mu}g/m^3$) suggested by previous investigators. It may be greatly caused by different physicochemical properties of MWCNT and their dispersion method and test rat data. For setting of regulatory OELs in CNT workplaces, further epidemiological studies in addition to animal studies are needed. More advanced technical methods such as CNT dispersion in air and liquid should be also developed.

Computed Tomographic Simulation of Craniospinal Irradiation (전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획)

  • Lee CI;Kim HN;Oh TY;Hwang DS;Park NS;Kye CS;Kim YS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

Study on Single-dose Intramuscular Toxicity of Shinbaro Pharmacopuncture in Sprague-Dawley (SD) Rats and Beagle Dogs (신바로 약침의 SD 랫드와 비글견에 대한 단회 근육투여 독성시험)

  • Lee, Jin-Ho;Chung, Hwa-Jin;Lee, In-Hee;Lee, Jae-Woong;Kim, Eun-Jee;Kim, Min-Jeong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.25 no.3
    • /
    • pp.1-9
    • /
    • 2015
  • Objectives To evaluate Shinbaro Pharmacopuncture safety through analysis of potential single-dose intramuscular toxicity of Sinbaro Pharmacopucture in SD rats and Beagle dogs. Methods Single-dose intramuscular toxicity of Shinbaro Pharmacopuncture was assessed in accordance with Korea Food and Drug Administration Guidelines for toxicity testing of Medicinal Products. The SD rats were treated intramuscularly with Shinbaro Pharmacopuncture at doses of 0, 4.6, 9.2, and 18.5 mg/kg, respectively. The Beagle dogs were treated intramuscularly with Shinbaro Pharmacopuncture at doses of 2.3, and 4.6 mg/kg, respectively, and after 3 days, the procedure was repeated a second time at doses of 0.6, and 1.2 mg/kg, respectively, for toxicity testing. Mortality, change in body weight, and necropsy findings were examined for the study period. Results There were no mortalities, general symptoms, or body weight changes in the SD rats. While pyelectasis of the left kidney was observed in a male rat in the 4.6 mg/kg administration group, natural occurrence is common, and does not appear to be related with the test substance. No mortalities were observed in the Beagle dogs. In assessment of general symptoms, a female dog in the 9.2 mg/kg group displayed body weight decrease due to leftover food, but the change in body weight was within the normal range seen at 6~7 months, and the necropsy findings were not significant. The toxicity of the test substance appears to be minimal. Conclusions The results suggest that the lethal dose 50 ($LD_{50}$) and approximate lethaldose (ALD) value in single intramuscular administration of Shinbaro Pharmacopuncture in SD rats and Beagle dogs are higher than 18.5 mg/kg.

Statatistical Analysis of Three Sequence-Three Periods Bioequivalence Study : Application to Bioequivalence Test of Ondansetron Formulations ($3{\times}3$ 라틴 방격법 모델에 따른 생물학적 동등성 시험의 통계 해석 : 온단세트론 제제에 대한 적용 예)

  • Lee, Young-Joo;Lee, Myung-Gull;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 1998
  • A $3{\times}3$ Latin square crossover study for the bioequivalence of three ondansetron formulations was conducted. Test products were $Vominon^{\circledR}$ 8 mg and $Vominon^{\circledR}$ 4 mg tablets and reference product was $Zofran^{\circledR}$ tablet. Twenty one healthy Korean male subjects received each formulation at the ondansetron dose of 8 mg and plasma concentrations of ondansetron were monitored by HPLC for over a period of 12 hr after the oral administration. Statistical procedure for bioequivalence evaluation of AUC {e.g., analysis of variance (ANOVA), multiple comparison and confidence intervals} was carried out. There were no significant differences in AUC among the formulations. The confidence intervals for the AUC of $Vominon^{\circledR}$ 8 mg and $Vominon^{\circledR}$ 4 mg were between -0.24 and 15.54% and between -2.41 and 13.36% respectively, within a range that proposed by the Korea Food and Drug Administration Guidelines for Bioequivalence. These statistical procedure could be standardized and generally applicable for the assessment of bioequivalence for multiple (more than two) formulations.

  • PDF

Abuse Liability Assessment of l-Deprenyl by Testing Methamphetamine-like Discriminative Effects (메탐페타민 유사 분별능 시험을 통한 l-디프레닐의 약물남용가능성 평가)

  • Lee, Sun-Hee;Kim, Pu-Young
    • YAKHAK HOEJI
    • /
    • v.42 no.1
    • /
    • pp.101-107
    • /
    • 1998
  • The antiparkinsonian agent l-deprenyl, a selective monoamine oxidase (MAO)-B inhibitor, is metabolized in part to l-methamphetamine and l-amphetamine. l< /I>-Deprenyl was evaluated for amphetamine and methamphetamine-like discriminative stimulus effects in rats and its mechanism of action was investigated. Rats were trained under a 5-response, fixed ratio schedule of stimulus-shock termination or a 10-response. Fixed-ratio schedule of food-presentation which discriminate between d-amphetamine (1mg/kg, i.p.) and saline or d-methamphetamine (1mg/kg, i.p.) and saline in a two-lever, operant conditioning procedure. Full generalization was obtained to d-amphetamine (1~3mg/kg). d-methamphetamine (1~3mg/kg) and l-deprenyl (17~30mg/kg) under both the food presentation and stimulus shock termination schedule. l-Deprenyl has dose-dependent amphetamine-and methamphetamine-like discriminative stimulus properties in rats only at doses of 17 and 30mg/kg. Reversible MAO-B inhibitor, RO 16-6491 didn`t show any amphetamine-like discriminative properties. Aromatic amino acid decarboxylase inhibitor, NSD 1015 decreased % responding of l-deprenyl in the methamphetamine-trained rats under the stimulus-shock termination schedule. SKF-525A produced partial inhibition of methamphetamine-like discriminative effects of l-deprenyl under the food presentation schedule. These results suggest that l-deprenyl has no abuse liability at the therapeutic range but there needs some caution at high doses and furthermore, drug discrimination studies under the food presentation and shock termination schedule are useful for the assessment of abuse liability of psychostimulants.

  • PDF