흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가 (Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality)

  • 김민경;곽형주;김종훈;최원호;하연경;이소정;김대호;이용구;이영진
    • 전자공학회논문지
    • /
    • 제53권9호
    • /
    • pp.143-147
    • /
    • 2016
  • 최근 디지털 단층영상합성 시스템 (digital tomosynthesis system, DTS)은 일반 X-ray의 영상 중첩현상과 전산화단층촬영장치 (computed tomography, CT)의 높은 선량의 문제점을 해결하기 위하여 개발되었다. 본 연구의 목적은 흉부 촬영용 디지털 단층영상합성 시스템 (chest digital tomosynthesis, CDT)의 재구성 알고리즘 개발 및 화질과 선량 평가를 수행하는 것이다. 영상의 재구성은 필터 후 역투영 (filtered back-projection, FBP)을 모델링하였고, 팬텀 영상을 획득하기 위한 X-선과 검출기 사이의 각도를 ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, 그리고 ${\pm}30^{\circ}$로 구성하였다. 영상의 화질 평가는 평균 제곱근 편차 (root mean square error, RMSE)와 신호대 잡음 변화율 (signal difference-to-noise ratio, SDNR)로 수행하였고, 선량 평가는 ${\pm}20^{\circ}$의 범위에서 유효선량으로 수행하였다. 결과적으로, 모든 각도에서 Slice thickness 필터를 적용한 팬텀영상이 가장 우수한 RMSE와 SDNR 결과를 나타내었고, 최종 유효 선량은 0.166 mSv로 측정되었다. 결론적으로, 개발한 CDT 재구성 알고리즘의 유용성을 증명하였고, 최종 유효 선량을 측정하여 CDT의 기초 실험 데이터를 구축할 수 있었다.

Panasonic UD-809P 알비도 열형광선량계를 이용한 중성자 개인선량당량 평가 (Neutron Personal Dose Equivalent Evaluation Using Panasonic UD-809P Type TLD Albedo Dosimeters)

  • 신상운;손중권;김화
    • Journal of Radiation Protection and Research
    • /
    • 제24권3호
    • /
    • pp.143-154
    • /
    • 1999
  • Panasonic UD-809P 알비도 중성자 열형광선량계를 팬텀에 장착시켜 원자력발전소에서 중성자 개인선량당량을 측정하였다. 측정된 판독값으로부터 Panasonic 사의 사용자 매뉴얼에 제시되어 있는 방법을 이용하여 열중성자와 초열중성자 및 속중성자로 인한 개인선량당량을 평가하였다. 그 결과 열중성자 성분의 비율이 높은 원자력발전소에서는 속중성자로 인한 개인선량당량을 적절하게 평가할 수 없는 것으로 확인되었는데, 이는 열중성자로 인한 알비도 성분이 열형광선량계로 재입사 되는 양이 이론적인 값과 상당한 차이가 나기 때문인 것으로 추정되었다. 따라서 원자력발전소와 같이 열중성자 성분의 비율이 높은 조건에서 속중성자로 인한 중성자 개인선량당량을 평가하기 위하여 중성자 성분을 열중성자와 속중성자로 구분한 새로운 중성자 선량계산 알고리즘을 제안하였으며, 각각의 성분에 대한 개인선량당량과 교정인자, 민감도 인자 평가공식을 유도하였다.

  • PDF

부정형 방사선 조사면에 대한 투과선량 보정 알고리즘 (Transmission Dose Estimation Algorithm for Irregularly Shaped Radiation Field)

  • 윤형근;지의규;허순녕;우홍균;이형구;신교철;김시용;하성환
    • Radiation Oncology Journal
    • /
    • 제20권3호
    • /
    • pp.274-282
    • /
    • 2002
  • 목적 : 방사선치료시 환자에 조사되는 방사선량을 매 치료시마다 간편하게 확인하기 위한 생체내(in vivo) 선량측정의 한 방법으로 투과선량을 이용하는 새로운 시스템에 필요한 알고리즘을 이미 개발한 바 있다. 본 연구에서는 조사면 일부가 차폐된 부정형 조사면에서 적용하기 위한 보정 알고리즘을 개발하고자 하였다. 재료 및 방법 : 알고리즘을 개발하기 위한 기본 자료를 마련하기 위하여 투과선량 측정을 시행하였다. 측정에는 선형가속기의 6 MV 및 10 MV의 X선을 이용하였고, 이온함형 측정기 및 전위계를 사용하였다. 측정조건으로는 조사면의 크기(collimator opening)는 $2\times2\;cm^2$에서 $32\times32\;cm^2$까지 한 변을 2 cm씩 증가시켜 16단계로 하였고, 팬톰 두께(phantom thickness; Tp)는 0, 10, 20 및 30 cm, 팬톰과 측정기간의 거리(phantom chamber distance; PCD)는 10, 30 및 50 cm으로 하였다. 이 때 조사면의 일부를 차폐하였으며 차폐되지 않은 유효조사면(effective field size)의 크기를 $5\times5,\;10\times10,\;15\times15$$20\times20\;cm^2$으로 하였다. 결과 : 조사면의 일부가 차폐체에 의하여 차폐된 경우 종양선량이 감소되며 동시에 투과선량도 감소된다는 물리학적인 추론을 이용하여 방사선조사면 일부 차폐가 투과선량에 미치는 영향을 보정하기 위한 알고리즘을 개발하였으며 조사면 일부가 차폐된 여러 측정 조건에서 알고리즘을 이용한 계산치와 실제측정치 간의 오차는 ${\pm}1.0\%$ 이내이었다. 결론 : 투과선량 계산 알고리즘은 조사면 일부가 차폐된 불규칙 조사면의 경우 ${\pm}1.0\%$ 이하의 오차 범위로 정확히 투과선량을 계산할 수 있음을 확인하였다.

투과선량을 이용한 생체내 (in vivo) 선량측정을 위한 알고리즘 (Transmission Dose Estimation Algorithm for in vivo Dosimertry)

  • 윤형근;지의규;허순녕;이형구;우홍균;신교철;김시용;하성환
    • Journal of Radiation Protection and Research
    • /
    • 제27권3호
    • /
    • pp.147-154
    • /
    • 2002
  • 연구 목적 : 각종 암 환자의 방사선치료시 환자에 조사되는 방사선량을 매 치료시마다 간편하게 확인하기 위한 생체내(in vivo) 선량측정의 한 방법으로 투과선량을 이용하는 새로운 시스템에 필요한 알고리즘을 개발하고자 하였다. 이를 위하여 본 교실에서 이미 개발한 바 있는 알고리즘을 개선하고자 하였다. 연구 재료 및 방법 : 알고리즘은 투과선량의 기본 측정치를 A/P (area-perimeter ratio)의 4차 함수로 회귀한 후에 각 계수들을 PCD (phantom-chamber distance)의 3차 함수로 회귀하여 구성하였다. 또한 기본 측정조건들의 감소 가능성을 확인하기 위하여 각각의 PCD 및 Tp (phantom thickness)당 조사야를 8개만 사용한 경우와 15개를 사용한 경우에서 측정치와 계산치를 비교하였다. 임의의 방사선조사조건에서의 알고리즘의 정확도를 확인하기 위하여 기본 측정 조건에 포함되지 않은 장방형의 방사선조사야, 기본 측정에 포함되지 않은 임의의 팬톰 두께, 임의의 PCD 조건에서 측정을 시행하고 알고리즘을 이용한 계산치와 비교하였다. 연구 결과 : 기본 측정치와 알고리즘을 이용한 계산치 간의 오차를 분석한 곁과 기존의 알고리즘에 비하여 정확도가 크게 향상되었으며 정방형 개방 조사야의 경우 오차의 범위를 ${\pm}0.5%$ 이내로 제한할 수 있었다. 또한 기돈 측정조건을 약 2분의 1로 감소시킬 수 있었다. 임의의 개방조사야의 방사선조사조건에서 측정을 시행하고 알고리즘을 이용한 계산치와 비교한 경우도 대부분의 경우 ${\pm}1.0%$ 이하의 오차를 나타내었다. 결론 : 악성종양환자의 방사선치료시 투과선량을 이용하여 환자에 조사되는 방사선량을 실시간으로 측정하기 위한 생체내 선량측정시스템이 필요한 개선된 알고리즘은 기본 측정자료를 약2분의 1로 축소한 경우에도 정방형 개방 조사야의 경우 ${\pm}0.5%$ 이하의 오차 범위, 장방형의 개방 조사야에서는 ${\pm}1.0%$ 이하의 오차 범위로 정확히 투과선량을 계산할 수 있음을 확인하였다.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

자궁경부암 근접치료 시 선량 검증 프로그램을 통한 임상적 위험성 평가 (Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer)

  • 강동진;신영주;강진규;정재용;이우진;백태성;이보람
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.553-560
    • /
    • 2022
  • The purpose of this study is to evaluate the clinical risk according to the applicator heterogeneity, mislocation, and tissue heterogeneity correction through a dose verification program during brachytherapy of cervical cancer. We performed image processing with MATLAB on images acquired with CT simulator. The source was modeled and stochiometric calibration and Monte-Carlo algorithm were applied based on dwell time and location to calculate the dose, and the secondary cancer risk was evaluated in the dose verification program. The result calculated by correcting for applicator and tissue heterogeneity showed a maximum dose of about 25% higher. In the bladder, the difference in excess absolute risk according to the heterogeneity correction was not significant. In the rectum, the difference in excess absolute risk was lower than that calculated by correcting applicator and tissue heterogeneity compared to the water-based calculation. In the femur, the water-based calculation result was the lowest, and the result calculated by correcting the applicator and tissue heterogeneity was 10% higher. A maximum of 14% dose difference occurred when the applicator mislocation was 20 mm in the Z-axis. In a future study, it is expected that a system that can independently verify the treatment plan can be developed by automating the interface between the treatment planning system and the dose verification program.

머신러닝 기반 신체 계측정보를 이용한 CT 피폭선량 예측모델 비교 (Comparison of CT Exposure Dose Prediction Models Using Machine Learning-based Body Measurement Information)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.503-509
    • /
    • 2020
  • This study aims to develop a patient-specific radiation exposure dose prediction model based on anthropometric data that can be easily measurable during CT examination, and to be used as basic data for DRL setting and radiation dose management system in the future. In addition, among the machine learning algorithms, the most suitable model for predicting exposure doses is presented. The data used in this study were chest CT scan data, and a data set was constructed based on the data including the patient's anthropometric data. In the pre-processing and sample selection of the data, out of the total number of samples of 250 samples, only chest CT scans were performed without using a contrast agent, and 110 samples including height and weight variables were extracted. Of the 110 samples extracted, 66% was used as a training set, and the remaining 44% were used as a test set for verification. The exposure dose was predicted through random forest, linear regression analysis, and SVM algorithm using Orange version 3.26.0, an open software as a machine learning algorithm. Results Algorithm model prediction accuracy was R^2 0.840 for random forest, R^2 0.969 for linear regression analysis, and R^2 0.189 for SVM. As a result of verifying the prediction rate of the algorithm model, the random forest is the highest with R^2 0.986 of the random forest, R^2 0.973 of the linear regression analysis, and R^2 of 0.204 of the SVM, indicating that the model has the best predictive power.

ISO 표준방사선장을 이용한 필름배지의 선량평가 알고리즘 개발 (Development of Dose Evaluation Algorithm for Film Badge Using ISO Reference Radiations)

  • 김장렬;장시영;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.37-44
    • /
    • 1995
  • 과학기술처의 개인방사선피폭선량평가에 관한 기술기준이 제정된 이후 TLD에 의한 개인피폭선량평가 기술은 많은 발전이 있었으나, 우리나라 대부분의 방사선관련 산업체에서 방사선 피폭관리용으로 사용되고 있는 필름배지의 정확한 선량평가기술을 확보하기 위한 연구는 아직도 미진한 상태이다. 따라서 본 연구에서는 ISO 표준방사선장을 이용하여 i) 실험식에 의한 방법, ii) Degree-of-fit에 의한 방법, 그리고 ) Matrix에 의한 방법으로 필름배지에 의한 선량평가 알고리즘개발방법을 제시하였다. 이러한 방법들에 의한 계산값은 조사량과 ANSI N13.11에서 제시하고 있는 성능지수 이내에서 잘 일치하였으며, 이는 X, ${\gamma}$ 혹은 혼합방사선장에서 선량평가에 유용하게 혼용될 수 있을 것이다.

  • PDF

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교 (Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams)

  • 정진범;엄근용;김인아;김재성;이정우;홍세미;김연래;박병문;강상원;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.210-217
    • /
    • 2014
  • 이 연구는 비편평화여과기(flattening filter-free, FFF) 빔을 이용한 폐 정위절제방사선치료(stereotactic ablative radiotherapy, SABR)에 대하여 서로 다른 선량계산 알고리즘의 선량적 효과를 조사하였다. SABR를 받은 10명의 폐암 환자를 대상으로하여 평가하였다. 모든 치료계획은 Eclipse 치료계획시스템의 Acuros XB (AXB) 알고리즘을 이용하여 수립되었다. 다른 선량계산 알고리즘과 비교를 위하여, 추가적으로 anisotropic analytic algorithm (AAA) 알고리즘을 적용한 치료계획을 재 수립하였다. 두 알고리즘 평가를 위해서, 치료표적과 손상위험장기의 선량체적히스토그램(dose-volume histogrim, DVH)를 분석하였다. 그리고 기술적 인자로써 계산시간과 총 MU 값을 평가하였다. DVH 비교분석을 통해, PTV의 최대선량은 AXB이 AAA 보다 5.2% 높았으며 최소선량은 4.4% 낮게 나타났다. PTV의 $V_{105%}$에서 7.06%까지 큰 차이를 나타났다. 폐의 최대선량은 AXB 치료계획에서 약간 크게 나타났다. 동측성 폐에 5, 10과 20 Gy 선량이 조사되는 체적은 AAA 보다 AXB에서 더 크게 나타났으나 대측성 폐에 대해서는 거의 비슷하게 나타났다. 척수와 심장에서 최대선량의 차이도 크지 않았다. 계산시간의 경우, AXB가 AAA보다 13.7% 정도 소요시간이 적었고 MU 값은 AXB에서 3.47% 더 많았다. 이 연구의 결과들은 회전조절치료 기법을 포함하여 FFF 빔이 적용된 폐 SABR 치료계획에서 AXB 알고리즘은 선량계산의 정확성과 계산시간의 감소의 장점을 제공할 수 있을 것이다.