• 제목/요약/키워드: Dose Verification

검색결과 227건 처리시간 0.023초

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system

  • Youngmo Ku;Sehoon Choi;Jaeho Cho;Sehyun Jang;Jong Hwi Jeong;Sung Hun Kim;Sungkoo Cho;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3140-3149
    • /
    • 2023
  • In theory, the sharp dose falloff at the distal end of a proton beam allows for high conformal dose to the target. However, conformity has not been fully achieved in practice, primarily due to beam range uncertainty, which is approximately 4% and varies slightly across institutions. To address this issue, we developed a new range verification system prototype: a multi-slit prompt-gamma camera (MSPGC). This system features high prompt-gamma detection sensitivity, an advanced range estimation algorithm, and a precise camera positioning system. We evaluated the range measurement precision of the prototype for single spot beams with varying energies, proton quantities, and positions, as well as for spot-scanning proton beams in a simulated SSPT treatment using a phantom. Our results demonstrated high accuracy (<0.4 mm) in range measurement for the tested beam energies and positions. Measurement precision increased significantly with the number of protons, achieving 1% precision with 5 × 108 protons. For spot-scanning proton beams, the prototype ensured more than 5 × 108 protons per spot with a 7 mm or larger spot aggregation, achieving 1% range measurement precision. Based on these findings, we anticipate that the clinical application of the new prototype will reduce range uncertainty (currently approximately 4%) to 1% or less.

선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향 (Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy)

  • 정재용;신영주;손승창;김연래;민정환;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.15-25
    • /
    • 2012
  • 부피적조절회전방사선치료(VMAT)의 정도관리를 TG-119에서 제시된 권고안을 통해 평가하고자 하였다. 또한 선택적 최적화 변수에 따른 치료계획의 평가와 그에 따른 선량학적 특성을 평가하고자 하였다. Varian사의 iX선형가속기와 Nucletron사의 Oncentra MasterPlan 치료계획장치를 결합하여 VMAT 치료계획을 수립하였다. TG-119에 제시된 5가지의 구조세트를 이용하여 아크 수, 겐트리 간격, 치료 시간 등의 선택적 최적화 변수(selectable optimization parameters)를 변화하여 치료 계획의 평가와 선량검증을 통해 정확성을 평가하였다. 치료계획의 평가는 선량체적히스토그램을 이용하여 표적과 위험장기의 평균값과 표준편차를 이용하였으며 선량검증은 이온 전리함과 $Delta^{4PT}$ bi-planar diode array를 이용하였다. 치료계획의 평가에서 싱글 아크의 경우 C-shape (hard)를 제외한 다른 구조세트에서 목표한 선량에 근접하는 결과를 보였으며 듀얼 아크의 경우에는 C-shape (hard)를 제외한 다른 구조세트에서 제시한 목표 선량에 도달하였다. 또한 선택 변수에 대한 평가에서는 전립선과 같은 간단한 구조 세트에서는 아크 수에 따른 치료계획의 차이는 거의 나타나지 않았으나, 두경부와 같은 복잡한 구조에서는 듀얼 아크가 위험장기에 대하여 좀 더 우수한 결과를 나타내었다. 겐트리 간격의 크기 변화에 의한 선량분포는 $6^{\circ}$에 비해 $4^{\circ}$의 겐트리 간격이 우수하였으나 $2^{\circ}$ 간격과는 거의 차이가 없었다. 점선 량의 정확성 평가에서는 표적과 위험장기에 대한 점선량의 측정값과 계산값의 평균오차는 싱글 아크와 듀얼 아크 모두 3% 이내였으며, 신뢰구간은 싱글아크와 듀얼 아크가 4% 내로 허용범위 안에 포함되었다. 겐트리 간격의 크기에 따른 점선량의 정확성 평가에서는 $2^{\circ}$, $4^{\circ}$, $6^{\circ}$ 모두 3% 이내였으며, 표적과 위험장기에 대한 신뢰한계(Confidence limit)는 5% 내로 허용범위 안에 포함되었다. $Delta^{4PT}$를 이용한 싱글 아크와 듀얼 아크의 선량분포 측정에서는 허용기준 3 mm/3%를 통과하는 감마인덱스는 평균 $98.72{\pm}1.52%$$98.30{\pm}1.50%$이었으며 신뢰한계는 2.99%와 3.74%로 허용범위 내에 포함되었다. 겐트리 간격의 크기에 따른 선량의 정확성은 간격이 적을수록 우수한 결과를 나타냈다. 본 연구에서는 VMAT의 정도관리를 TG-119에서 제시된 시험을 수행하였으며 제시된 모든 구조 세트에 대하여 허용기준을 모두 만족하였다. 또한 사용자가 선택할 수 있는 최적화 변수의 변화에 대한 치료계획과 선량학적 영향을 분석하였으며 각 상황에 따른 임상적 특성에 맞는 변수를 선택하는 것이 중요하다고 사료된다.

6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구 (A Study on Design and Application of Tissue Compensator for 6MV X-rays)

  • 채규영;최은경;정웅기;강위생;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

  • Park, Kyeongjin;Kim, Jinhwan;Lim, Kyung Taek;Kim, Junhyeok;Chang, Hojong;Kim, Hyunduk;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1991-1997
    • /
    • 2019
  • In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H* (10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 × 3 ㎟ PIN diode coupled to a 3 × 3 × 3 ㎣ CsI (Tl) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H* (10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H* (10) from the gamma spectra was verified by using 241Am, 137Cs, 22Na, 54Mn, and 60Co radioisotopes. Furthermore, gamma spectra and H* (10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H* (10) based on the G(E) function for the gamma spectra was then compared with H* (10) calculated by simulation. The relative difference of H* (10) from various single-source spectra was in the range of ±2.89%, and the relative difference of H* (10) for a multiple isotope case was in the range of ±5.56%.

머신러닝 기반 신체 계측정보를 이용한 CT 피폭선량 예측모델 비교 (Comparison of CT Exposure Dose Prediction Models Using Machine Learning-based Body Measurement Information)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.503-509
    • /
    • 2020
  • This study aims to develop a patient-specific radiation exposure dose prediction model based on anthropometric data that can be easily measurable during CT examination, and to be used as basic data for DRL setting and radiation dose management system in the future. In addition, among the machine learning algorithms, the most suitable model for predicting exposure doses is presented. The data used in this study were chest CT scan data, and a data set was constructed based on the data including the patient's anthropometric data. In the pre-processing and sample selection of the data, out of the total number of samples of 250 samples, only chest CT scans were performed without using a contrast agent, and 110 samples including height and weight variables were extracted. Of the 110 samples extracted, 66% was used as a training set, and the remaining 44% were used as a test set for verification. The exposure dose was predicted through random forest, linear regression analysis, and SVM algorithm using Orange version 3.26.0, an open software as a machine learning algorithm. Results Algorithm model prediction accuracy was R^2 0.840 for random forest, R^2 0.969 for linear regression analysis, and R^2 0.189 for SVM. As a result of verifying the prediction rate of the algorithm model, the random forest is the highest with R^2 0.986 of the random forest, R^2 0.973 of the linear regression analysis, and R^2 of 0.204 of the SVM, indicating that the model has the best predictive power.

$PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발 (Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry)

  • 조웅;이재기;김현석;우홍균
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.233-241
    • /
    • 2014
  • 본 연구에서는 $PRESAGE^{REU}$ 겔을 이용하여 방사선 치료계획 시 3차원 흡수선량 분포 검증을 위한 정도 관리 소프트웨어를 개발하여 겔을 이용한 3차원 선량분석 방법을 제시하고자 한다. 우선 치료계획상의 3차원 흡수선량 데이터와 측정한 겔 광학밀도 데이터의 입출력 기능을 구현하였고, 변환 테이블을 이용하여 광학밀도를 흡수선량으로 변환하는 기능을 구현하였다. 겔에서 측정된 흡수선량과 치료계획상의 흡수선량 분포간의 기하학적 매칭을 위하여 3D 볼륨 데이터의 x, y, z 방향 및 회전 변환을 구현하였다. 매칭이 완료된 두 선량 분포간에 일치도를 검증하기 위하여 3차원 감마 인덱스알고리듬을 구현하였고, 감마 통과 지도(gamma passing map) 기반의 일치도 확인 기능을 구현하였다. 광학밀도와 흡수선량간의 관계를 분석하기 위하여 원기둥 형태의 $PRESAGE^{REU}$ 겔을 대상으로 X-선 전산화 단층촬영기를 이용하여 CT 영상을 획득하였고, 방사선 치료계획 시스템(Eclipse, Varian, Palo Alto)을 이용하여 원반 형태의 6개의 가상 표적을 생성하여, 각각에 1 Gy에서 6 Gy까지 선량이 전달되도록 입체조형 방사선 치료계획을 수립하였다. 다음으로 광학 CT 스캐너($Vista^{TM}$, Modus Medical Devices Inc, Canada)를 이용하여 기준 투영 영상들을 획득하였고, 치료계획과 동일하게 겔에 방사선을 조사하였다. 조사2시간 후 매 2시간 간격으로 광학 CT 스캐너로 투영 영상 셋을 획득 후 3차원 광학밀도 데이터로 재구성하였다. 실린더 중심축을 따라 치료계획상의 흡수선량 프로파일과 광학밀도 프로파일을 추출하여 광학선량 대비 흡수선량 대응 테이블을 정의하였다. 이후 본 연구에서 개발한 소프트웨어를 이용하여 3차원상의 선량 분포의 일치도를 평가하였다. 광학밀도와 흡수선량간에는 supra-linear 관계가 나타났으며, 광학밀도는 그 크기에 따라 24시간당 60% 전후로 감쇄하였다. 측정된 흡수선량은 중심축 부근에서는 치료계획 선량과 잘 일치하였으나, 주변부로 갈수록 크게 낮아짐을 확인할 수 있었으며, 이로 인하여 3D 감마 통과율은 선량 차이율과 DtoA 각각 3%/3 mm의 조건하에 70.36%로 낮게 나타났다. 이러한 결과는 광학 CT 스캐너 내부의 오일과 $PRESAGE^{REU}$ 겔간의 굴절률이 정확하게 매칭되지 않아서 광학 스캔 시 빔이 굴절되어 부정확한 데이터를 만들어 내는 것으로 분석되었다. 본 연구에서 개발한 정도 관리소프트웨어는 3차원 겔 선량을 비교 분석하기에 유효한 것으로 평가되었으나, $PRESAGE^{REU}$ 겔로부터 정확한 흡수선량데이터를 획득하기 위해 겔 선량측정 과정의 많은 개선이 요구된다.

입체조형 동적회전조사 방사선치료의 선량 검증 (Dosimetric Verification of Dynamic Conformal Arc Radiotherapy)

  • 김태현;신동호;이두현;박성용;윤명근;신경환;표홍렬;김주영;김대용;조관호;양대식;김철용
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.166-175
    • /
    • 2005
  • 입체조형 동적회전조사 방사선치료(Dynamic Conformal Arc Radiotherapy, DCAR)에서 필름 선량계를 이용한 선량검증시 필름 회전중심점 이동 보정값을 최적화법으로 구하고 최적화 후 DCAR에 대한 선량 검증의 정량적 허용기준을 제시하고자 하였다. 정위방사선치료를 시행했던 7명의 전이성 뇌암 환자에서 DCAR 치료계획을 시행하고 필름 선량계로 선량을 측정하였다. 필름 선량계의 가장 큰 계통적 오차 요인인 회전중심점 이동 보정값을 최적화법으로 구하고 치료계획과 필름으로 측정된 선량분포를 비교하여 최적화 전후의 평균 선량오차와 점선량오차가 $5\%$ 이상인 지점의 비율을 얻었다. 모든 환자에서 필름 선량계의 회전중심점 이동 보정값은 1 mm 이내였다. 필름 회전중심점 이동 보정 최적화전, 후로 선량오차 결과를 산출하였다. 최적화 전, 후의 평균 선량오차의 평균은 각각 $1.70{\pm}0.36\%$, $1.34{\pm}0.20\%$이었고 점선량오차가 $5\%$ 이상인 지점 비율의 평균은 각각 $4.54{\pm}3.94\%$, $0.11{\pm}0.12\%$로서 최적화 후 선량오차가 현저히 감소하였다. 본 연구의 결과와 같이 최적화법을 이용한 필름의 회전중심점 이동값을 구하고 최적화 후의 평균 선량오차와 점선량오차가 $5\%$ 이상인 지점의 비율을 구하는 방법은 임상에서 DCAR에 대한 선량 검증 방법으로 유용하게 사용될 수 있을 것으로 기대된다.

  • PDF

렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교 (Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique)

  • 허병익
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.9-17
    • /
    • 2017
  • 감마나이프 방사선수술(GKRS)의 높은 정밀도와 정확성은 치료 성공을 위한 기본 요건이다. 방사선의 급격한 감소와 함께 정교한 방사선 전달 및 선량 기울기가 임상적으로 적용되어야 하므로 방사선량 측정 및 기하학적 정확성을 보장하고 감마나이프 방사선수술에서 발생할 수 있는 모든 위험 요인을 줄이기 위해서는 전용 정도관리(QA) 프로그램이 필요하다. 본 연구에서는 독립적인 검증 프로그램 가변 타원체 모형화기술(Variable Ellipsoid Modeling Technique: VEMT)을 적용해서 감마나이프 치료계획 시스템 렉셀 감마플랜의 알고리즘에 사용된 단일 샷 선량 분포의 정확성을 검증하였다. 감마나이프 퍼펙션(PFX)에 장착한 직경 160 mm의 구형 ABC 팬텀에 조사한 단일 샷의 선량 분포를 평가했다. 단일 샷의 조사는 ABC 팬텀의 중심으로 향하게 하여 x, y 및 z 축을 따라 4, 8 및 16 mm 크기의 시준기 배치가 고려되었다. 감마나이프 방사선수술에서 사용되는 감마나이프 퍼펙션 치료계획 시스템은 렉셀 감마플랜(LGP) 버전 10.1.1이 사용되었다. VEMT의 검증을 통해서 감마나이프 방사선수술의 정확성은 배가 될 것이다. 그래서 VEMT 검증 후 감마나이프 방사선수술의 정확성과 정밀성을 토대로 임상 적용이 최종적으로 수행되어야 한다. 특히 환자의 머리가 직경 160mm의 구형으로 시뮬레이션된 조건에서 50% 등선량 높이 수준의 너비, 즉 최대반값폭(FWHM)이 검토되었다. VEMT를 통해 예측된 x, y, z 축의 선량 분포에 관한 모든 데이터는 4 mm 및 8 mm 시준기 배치에 대해 z 축을 따라 최대반값폭과 반그늘(PENUMBRA)의 약간의 차이점을 제외하고는 사양 내(등선량 50%에서 1 mm 이내)에서 LGP의 선량 분포와 훌륭하게 일치했다. 최대반값폭의 최대 불일치는 모든 시준기 배치에서 2.3% 미만이었다. 반그늘의 최대 불일치는 z 축을 따라 8 mm 시준기에 대해서 0.07 mm로 주어졌다. VEMT와 LGP로 얻은 선량 분포에서 최대반값폭과 반그늘의 차이는 감마나이프 방사선수술에서 임상적 유의성을 부여하기에는 너무 작았다. 이 연구의 결과는 전 세계 감마나이프 방사선수술에 관련된 의학물리학자를 위한 참고 자료로 활용될 수 있으리라 사료된다. 따라서 우리는 LGP의 결과물에 대한 독립적인 검증방법 VEMT를 포함하는 정기 예방정비 프로그램을 통해 결정된 모든 시준기 배치에 대한 선량 분포의 유효성을 확인하고 감마나이프 방사선수술 환자에게 임상적으로 완벽한 치료를 보장할 수 있다. 그래서 VEMT의 활용은 시스템을 안전하게 검증하고 운영할 수 있는 정도관리의 한 부분이 될 것으로 기대한다.

MLC 로그 파일 기반 DQA에서 타깃 용적에 따른 영향 연구 (The Study on the Effect of Target Volume in DQA based on MLC log file)

  • 신동진;정동민;조강철;김지훈;윤종원;조정희
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.53-59
    • /
    • 2020
  • 목 적: 본 연구의 목적은 타깃 용적의 변화에 따라 MLC 로그 파일 기반 소프트웨어(Mobius)와 기존의 팬텀-전리함(ArcCheck) 선량 검증 방법 간에 차이를 비교 분석하는데 목적이 있다. 대상 및 방법: 반지름이 0.25cm, 0.5cm, 1cm, 2cm, 3cm, 4cm, 5cm, 6cm, 7cm, 8cm, 9cm, 10cm까지 총 12개의 球(구) 모양 타깃이 있는 플랜을 생성하고 Mobius와 ArcCheck을 사용한 선량 검증을 각각 3번씩 실시하였다. 조사된 데이터를 점선량 오차값과 감마 통과율(3%/3mm)을 평가지표로 하여 비교 분석하였다. 결 과: Mobius의 점선량 오차값은 반지름 0.25cm에서 -9.87%, 0.5cm에서 -4.39%로 나타났고, 나머지 타깃 용적에서 오차값은 3% 이내로 나타났다. 감마 통과율은 반지름 9cm에서 95%, 10cm에서 93.9%로 나타났고, 나머지 타깃 용적에서는 95% 이상의 통과율을 보였다. ArcCheck에서 점선량 평균 오차값은 모든 타깃 용적에서 2% 내외의 일치율을 보였다. 감마 통과율 역시 모든 타깃 용적에서 98% 이상의 통과율을 보였다. 결 론: 반지름 0.5cm 이하의 작은 타깃이나 반지름 9cm 이상의 큰 타깃에서는 MLC 로그 파일 기반 DQA의 불확실성을 고려하여, 팬텀-전리함 기반 DQA를 상호 보완해서 사용함으로써 점선량, 감마 지표, DVH, 타깃 포함 등의 종합적인 분석으로 선량 전달 검증을 하는 것이 바람직하다고 사료된다.