In vivo dosimetry and acute toxicity in breast cancer patients undergoing intraoperative radiotherapy as boost

  • Lee, Jason Joon Bock;Choi, Jinhyun;Ahn, Sung Gwe;Jeong, Joon;Lee, Ik Jae;Park, Kwangwoo;Kim, Kangpyo;Kim, Jun Won
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.121-128
    • /
    • 2017
  • Purpose: To report the results of a correlation analysis of skin dose assessed by in vivo dosimetry and the incidence of acute toxicity. This is a phase 2 trial evaluating the feasibility of intraoperative radiotherapy (IORT) as a boost for breast cancer patients. Materials and Methods: Eligible patients were treated with IORT of 20 Gy followed by whole breast irradiation (WBI) of 46 Gy. A total of 55 patients with a minimum follow-up of 1 month after WBI were evaluated. Optically stimulated luminescence dosimeter (OSLD) detected radiation dose delivered to the skin during IORT. Acute toxicity was recorded according to the Common Terminology Criteria for Adverse Events v4.0. Clinical parameters were correlated with seroma formation and maximum skin dose. Results: Median follow-up after IORT was 25.9 weeks (range, 12.7 to 50.3 weeks). Prior to WBI, only one patient developed acute toxicity. Following WBI, 30 patients experienced grade 1 skin toxicity and three patients had grade 2 skin toxicity. Skin dose during IORT exceeded 5 Gy in two patients: with grade 2 complications around the surgical scar in one patient who received 8.42 Gy. Breast volume on preoperative images (p = 0.001), ratio of applicator diameter and breast volume (p = 0.002), and distance between skin and tumor (p = 0.003) showed significant correlations with maximum skin dose. Conclusions: IORT as a boost was well-tolerated among Korean women without severe acute complication. In vivo dosimetry with OSLD can help ensure safe delivery of IORT as a boost.

Population Dose Assessment for Radiation Emergency in Complex Terrain (복잡 지형에서의 주민선량 계산)

  • Yoon, Yea-Chang;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.2
    • /
    • pp.28-36
    • /
    • 1987
  • Gaussian plume model is used to assess environmental dose for abnormal radioactive release in nuclear facility, but there has a problem to use it for complex terrain. In this report, MATTEW and WIND04 Codes which had been verified were used to calculate wind field in the complex terrain. Under the base of these codes principle, wind fields were obtained from the calculation of the finite difference approximation for advection-diffusion equations which satisfy the mass-conservative law. Particle concentrations and external doses were calculated by using PIC model which approximate the particle to radioactive cloud, and atmospheric diffusion of the particles from the random walk method. The results show that the adjusted wind fields and the distributions of the exposure dose vary with the topography of the complex terrain.

  • PDF

The Use of Lens Shielding Device(L.S.D.) for a Conjunctival Lymphoma

  • Cho Hyun Sang;Ju Sang Gyu;Song Ki Won;Park Young Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.40-45
    • /
    • 1997
  • When therapeutic irradiation is indicated for the orbital tumors, the greatest concern is the risk of radiation-induced cataract. Conjunctival lymphoma is one of the good examples. We would like to report the procedure of the lens shielding device(L.S.D) and the result of irradiated dose to the lens. L.S.D. consistes of two parts : load alloy to attenuate electron beam, and dental acryl which completely covers the lead alloy to avoid discomfort of cornea from contacting directly with cerrobend and side scattering by cerrobend. And for easy location and removal, side bars were made on each side. Radiation doses were meaured with TLD(TLD 3500 Hawshaw). Markus chamber in a polystyrene phantom. The phantom was irradiated with 9MeV electron beams from Clinac 2100C with $6{\times}6cm$ electron cone. The relative dose at 6mm depth where the lens is located was $4.2\%$ with TLD and $5.1\%$ with Markus chamber clinically when 2600 cGy are irradiated to the eyeball, the mapinary dose to the lens will be 109 cGy or 132 cGy, which will significently reduce the cataract.

  • PDF

HAUSAT-2 SPACE RADIATION ENVIRONMENT AND EFFECTS ANALYSIS (HAUSAT-2 우주방사능 환경과 영향 분석)

  • Jung Ji-wan;Chang Young-Keun
    • Bulletin of the Korean Space Science Society
    • /
    • 2005.04a
    • /
    • pp.143-147
    • /
    • 2005
  • This paper describes the analysis of radiation environment and effects. TID(Total ionizing Dose) and SEE(Single Event Effects) analysis are implemented. The HAUSAT-2 is a 25kg class nanosatellite which is operated at sun-synchronous orbit at an altitude 650km. Trapped proton and Electron, Solar Proton, Galactic Cosmic Ray models are considered to HAUSAT-2 radiation environment model. Total Dose-depth curve provides TID degree and components are verified by DMBP method and Sectoring analysis. SEE are analysed with Radiation Test Report. Existing Radiation Test Reports are use to SEE analysis of HAUSAT-2.

  • PDF

A Case of Amiodarone-Induced Pulmonary Toxicity After a Long Course of a Low Dose Therapy (장기간 사용한 저용량 Amiodarone에 의한 폐독성 1예)

  • Ryu, Jung-Il;Lee, Wan-Suk;Hyun, Dae-Sung;Lee, Sang-Chae;Shin, Tae-Rim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.656-661
    • /
    • 2002
  • Amidarone is one of the most commonly prescribed anti-arrythmic agents for almost all arrythmias, whether atrial or ventricular in origin. There are several side effects associated with amiodarone therapy. These include corneal deposits, abnormal liver function tests, hyper and hypothyroidism, bluish discolorations of the skin, bone marrow suppression, coagulopathies, peripheral neuropathies, and pulmonary toxicity. Amiodarone-induced pulmonary toxicity(APT), which was first described in 1980, is potentially serious side effects that are believed to develop in 5% of patients. Doctors often assume that APT occurs only when high amiodarone doses are used for a long time, but in practice a low maintenance dose of amiodarone may also be toxic. In this report, a case of amiodarone-induced pulmonary toxicity after a long course of a low dose therapy for refractory supraventricular arrythmia is described.

Identification of troglitazone responsive genes: induction of RTP801 during troglitazone-induced apoptosis in Hep 3B cells

  • Kim, Jin-Oh;Kim, Ji-Young;Kwack, Mi-Hee;Hong, Su-Hyung;Kim, Moon-Kyu;Kim, Jung-Chul;Sung, Young-Kwan
    • BMB Reports
    • /
    • v.43 no.9
    • /
    • pp.599-603
    • /
    • 2010
  • Troglitazone is an anti-diabetic agent that improves hyperglycemia by reducing peripheral insulin resistance in type II diabetic patients. Troglitazone has been shown to cause growth inhibition of various normal and cancerous cells. However, the molecular mechanism by which troglitazone affects the growth of these cancer cells remains unclear. Here, we report that troglitazone treatment of Hep 3B human hepatocellular carcinoma cells resulted in dose-dependent growth inhibition. Analysis of cell cycle distribution by flow cytometry showed that the number of apoptotic cells was increased in a dose-dependent manner in response to troglitazone treatment. cDNA microarray analysis showed a number of differentially expressed genes in response to troglitazone. Among the upregulated genes, hypoxia-inducible factor 1 (HIF-1)-responsive RTP801 was induced in a dose-dependent manner. We also observed HIF-1 accumulation by immnocytochemistry after troglitazone treatment. These results strongly suggest that RTP801 might be involved in troglitazone-induced apoptosis in Hep 3B cells.

Epidural Administration of Morphine for Cancer Pain via Portal System (경막외 Port 및 주입기를 이용한 지속적 모르핀 투여에 의한 암성 통증 조절)

  • Yoon, Duck-Mi;Chung, So-Young;Oh, Hung-Kun;Kim, Ju-Yeon
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.69-74
    • /
    • 1996
  • Background: Efficacy of spinal opioids for the treatment of intractable cancer pain has been reported by several authors. The epidural route seems to be a more reliable and effective method of pain control as compared to the intrathecal route which can lead to opioids by portal system. Methods: Medical records were reviewed of 18 patients who had been treated with epidural morphine via an implanted port-A-Cath from Mar. 1991 to Sep. 1994. Results: Patients were treated for a mean of 92 days. There were wide variation of dose requirements. The minimum daily dose ranged from 2 to 10mg, and maximum daily dose from 3 to 30 mg. Verbal rating scale were below moderate until 100th days after posrtal implantation. When 3 patients suffered from aggravated pain associated with vertebral metastasis. Five of 11 patients who were administered medication longer than 50 days reguired increased doses ranging from 3 mg to 25 mg which were higher as compared to initial doses. These patients also experienced pain due to vertebral metastasis. There were no report of epidural scarring, respiratory depression, epidural infections, meningitis, or catheter blockade. Conclusion: Continuous epidural morphine administration via Port-A-Cath is an effective method with minimal complication.

  • PDF

Dosimetry of Irregular Field Using Thermoluminescence Dosimetry (부정형 조사면에서의 TLD를 이용한 방사선 흡수선량 측정)

  • Lee, Jong-Young;Park, Kyung-Ran;Kim, Kye-Jun
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.263-267
    • /
    • 1994
  • In clinical radiotherapy, the use of wide and irregular field techniques frequently results in considerable tumor dose inhomogeneity because of, the variation in physical characteristics of irradiated volumes. This report describes an analysis of the dosimetry of the irregular fields such as radiation fields for Hodgkin's disease(mantle field), esophageal cancer, and lung cancer when a 6 MV and a 15 MV linear accelerators are utilized. Doses were measured in a Rando phantom using methods of thermoluminescence dosimetry(TLD), and were calculated by radiotherapy planning computer system with the Clarkson's method for calculation of a irregular field. A dose variation of $5-22\%,\;6-9\%,\;6-14\%$ were found in the mantle field, esophageal cancer field, lung cancer field respectively. Higher doses occurred in the superior portion of the irregular field. The sites of maximum dose variation were the supraclavicular and the upper spinal cord region. To adjust for these substantial differences, a compensator or a shrinking field technique should be adopted.

  • PDF

Successful engraftment after infusion of multiple low doses of CD34+ cells from a poorly matched sibling donor in a patient with severe aplastic anemia

  • Kum, Chang Dae;Lee, Mi Jin;Park, Jun Eun
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.148-151
    • /
    • 2019
  • The dose of CD34+ cells is known to influence the outcome of allogeneic peripheral blood stem cell (PBSC) and/or T-cell-depleted transplantation. A previous study proposed that $2{\times}10^6\;CD34+\;cells/kg$ is the ideal minimum dose for allogeneic transplantation, although lower doses did not preclude successful therapy. In the case we present here, CD34+ cells were collected from a matched sibling donor on the day of allogeneic hematopoietic stem cell transplantation; however, the number of cells was not sufficient for transplantation. Consequently, PBSCs were collected three additional times and were infused along with cord blood cells from the donor that were cryopreserved at birth. The cumulative dose of total nuclear cells and CD34+ cells was $15.9{\times}10^8\;cells/kg$ and $0.95{\times}10^6\;cells/kg$, respectively. White blood cells from this patient were engrafted on day 12. In summary, we report successful engraftment after infusion of multiple low doses of CD34+ cells in a patient with severe aplastic anemia.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.