• Title/Summary/Keyword: Dorsum of the finger

Search Result 15, Processing Time 0.022 seconds

Turrets Exostosis with Swan Neck Deformity: An Unusual Occurrence

  • Mruthyunjaya, Mruthyunjaya;Nekkanti, Supreeth;Venkateshaiah, Sheshagiri;Siddartha, Arunodhaya;Thottimane, Pramod;Pimpale, Tushar
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.277-280
    • /
    • 2018
  • Turrets exostosis are extremely rare to occur. Benign bony outgrowths from the dorsum of the phalanges following trauma are termed Turrets exostosis. We report an unusual case of Turrets exostosis of the fourth finger with no preceding trauma which has never been reported before. A 50-year-old female patient presented to us with a bony swelling on the dorsum of the fourth finger of her right hand in one year. The swelling was dormant initially and started to progress in size since three months leading to pain, restriction of movements and deformity of the finger. Turrets exostosis are very rare to occur. A preceding history of trauma is not necessary for it to occur as described in the literature. Surgical excision yields good results and is indicated when the bony mass causes a progressive deformity of the finger and restriction of movements of the finger.

Soft Tissue Reconstruction of Finger and Hand Using Arterialized Venous Free Flap (동맥화 정맥 유리 피판술을 이용한 수부와 수지 연부조직 결손의 재건)

  • Kong, Byeong-Seon;Kim, Yong-Jin;Cho, Kwang-Woo
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.2
    • /
    • pp.107-116
    • /
    • 2004
  • Flaps are necessary, when important structures such as bone, tendon, nerve and vessel are exposed. Arterialized venous free flap is suited to the coverage of finger and hand because the thickness of venous flap is thin. Authors performed 65 cases arterialized venous free flap for the soft tissue reconstruction of the hand and finger. The size of donor defect were from $1{\times}1cm\;to\;7{\times}12cm$. The mean flap area was $9.1cm^2$. The recipient sites were finger tip in 34 cases, finger shaft in 29 cases and hand in 2 cases. The donor sites were volar aspect of distal forearm in 40 cases, thenar area in 17 cases and foot dorsum in 6 cases. The types of arterialized venous free flap were A-A type in 4 cases and A-V type in 61 cases. The length of afferent vein was from 0.5 cm to 3 cm (mean 1.7 cm) and efferent vein was from 1 cm to 10 cm (mean 2.2 cm). 58 flaps(89.2%) survived eventually. 42 flaps(64.6%) survived totally without any complication. 8 flaps(12.3%) showed the partial necrosis but they were healed without any additional operations. 8 flaps (12.3%) showed the partial necrosis requiring the additional skin graft. We had a satisfactory result by using arterialized venous free flap for the soft tissue reconstruction of finger and hand. We believe that volar aspect of distal forearm, thenar area, foot dorsum are suited as a donor site and the short length of the flap pedicle, the strong arterail inflow affect the survival rate of arterialized venous free flaps.

  • PDF

Neurovascular Island Flap Transfer from a Dorsum of the Finger (수지 배측 피부를 이용한 신경혈관 도서형 피판술)

  • Kim, Poong-Taek;Kim, Ik-Dong;Kim, Jae-Hyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.10-14
    • /
    • 1998
  • When covering a skin defect of the finger with a local flap is difficult, a vascular island flap is often used. For a palmar skin defect, it is desirable to add a sensory supply to the flap. This report describes a neurovascular island flap that was used to repair a palmar skin defect, the donor skin coming from the dorsal region of the middle phalanx. This flap is elevated with a vascular pedicle of the palmar digital artery and its dorsal skin branch, including the dorsal digital veins, palmar digital nerve and its cutaneous branches. The advantage of this flap are that it can be transferred with ease and without any tension. No special manipulation is required under a microscope and operation can be performed under a simple nerve-block. There if little possibility that the flap itself undergoes ischemic change or congestion. The disadvantage of this flap are that a skin graft is required at the donor skin site and one palmar digital aretery is lost. We think that this neurovascular island flap is one of the useful methods for skin defects that are difficult to cover with a local flap.

  • PDF

Use of Heparin Cream for Venous Congestion in the Extended Reverse Metacarpal Artery Flap: A Case Report

  • Tatar, Burak Erguun;Sabanciogullarindan, Fahri;Gelbal, Caner;Bozkurt, Mehmet
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.663-667
    • /
    • 2022
  • Finger dorsum defects are a challenging situation. Many reconstruction methods are used in these defects. Extended reverse dorsal metacarpal artery (RDMA) flap is used in dorsal finger reconstruction. Venous congestion in this flap is most important cause of flap failure. In this case, we presented a case in which we used heparin cream due to development of venous congestion in our patient who underwent an extended RDMA flap. A 24-year-old female patient presented to the emergency department with a defect of dorsal of left-hand fourth finger. Defect was covered with an extended RDMA flap. On postoperative first day, venous congestion was observed, and heparin cream was applied three times a day on flap. The signs of venous congestion were regressed. Tissue healed as a result of superficial epidermolysis and skin grafting. No functional limitation was observed in sixth-month postoperative control. Venous congestion is the most important cause of flap failure of extended RDMA flaps. Generally, subcutaneous heparin administration and leech therapy are used. In our case, heparin was applied as a cream instead of subcutaneously, and flap healing was observed as a result of superficial epidermolysis. Heparin cream application can also be used as a treatment option in flaps with venous congestion.

The Oblique Extended Reverse First Dorsal Metacarpal Artery Perforator Flap for Coverage of the Radial-Volar Defect of the Proximal Interphalangeal Joint in the Index Finger: A Case Report

  • Jeeyoon Kim;Bommie Florence Seo;Junho Lee;Sung No Jung
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.760-763
    • /
    • 2022
  • The dorsal metacarpal artery perforator flap is a flap that rises from the hand dorsum. Owing to its reliability and versatility, this flap is used as a workhorse for finger defect. However, to cover the radial-volar defect of the proximal interphalangeal joint (PIPJ) of the index finger, a longer flap is required than before. Here, we introduce the oblique extended reverse first dorsal metacarpal artery (FDMA) perforator flap to cover the radial-volar aspect defect of the index finger. A 45-year-old man got injured to the radial-volar defect of PIPJ of the left index finger caused by thermal press machine. The wound was 2 × 1 cm in size, and the joint and bone were exposed. We used FDMA perforator from anastomosis with palmar metacarpal artery at metacarpal neck. Since the defect was extended to the volar side, the flap was elevated by oblique extension to the fourth metacarpal base level. The fascia was included to the flap, and the flap was rotated counterclockwise. Finally, PIPJ was fully covered by the flap. Donor site was primarily closed. After 12 months of operation, the flap was stable without complication and limitation of range of motion. The oblique extended reverse FDMA perforator flap is a reliable method for covering the radial-volar defect of the PIPJ of the index finger. This flap, which also has an aesthetic advantage, will be a good choice for hand surgeons who want to cover the PIPJ defect of the index finger using a nonmicrosurgical option.

Raynaud`s Disease: One Case Report (Raynaud 씨 병: 1 치험례)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.6 no.2
    • /
    • pp.213-218
    • /
    • 1973
  • Raynaud attempted to clarify the situation concerning symmetrical and spontaneous gangrene in a thesis published in 1952. The disease was defined as Raynaud`s phenomenon without associated and contributing conditions or disease, and described as two types, such as, `locale syncope and asphyxia` and `gangrene`. Predilection of Raynaud`s disease for female under 40 years of age wi-thout any vascular occlusive disease beginning in the early decades of life and typical color changes in the skin of the extremities incited by coldness are outstanding features in this disease. One typical case of Raynaud`s disease is presented with relating references. Patient was 24 year old female single patient, who noted pain, numbness, and cyanosis of the finger tips of both hands for 6 years previously in the winter season, and recently such symptoms were aggravated including her both feet for two years even in the summer after exposure to cold water. Physical and laboratory examination revealed nothing specific except slightly glistening tight face and hypertrophy of both finger tips with clammy coldness. FamiliaI and past history revealed nothing specific abnormal contributory factors. Biopsy of skin on the dorsum of right foot one year before this admission revealed no evidence of scleroderma. Treatment was aimed to relieve vasospasmodic reaction to coldness and was very successful with bilateral lumbar and thoracic sympathectomy. Patient is free of symptoms relating to the Raynaud’s phenomenon after sympathectomy for 6 months including winter season.

  • PDF

A Case of Disseminated Multiple Glomus Tumors (파종성 다발성 사구종양 1례의 치험례)

  • Choi, Tae Hyun;Yeo, Hyeon Jung;Son, Daegu;Kim, Hyung Tae
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.493-496
    • /
    • 2009
  • Purpose: Glomus tumors are neoplasms that are composed of modified smooth muscle cells of the glomus body and multiple glomus tumor comprises 10% of all glomus tumors. We report a case of disseminated multiple glomus tumors. Methods: A 14 - year - old boy presented with multiple subcutaneous purple nodules on the right cheek, back, right arm, right hand dorsum, right fourth finger, and left ankle. Nodules on the back and right fourth finger were completely excised under local anesthesia and histopathologic examination was followed. Results: Histopathologic findings showed numerous dilated, cavernous - like, thin - walled, vascular spaces surrounded by one or a few layers of glomus cells. On immunohistochemical examination, glomus cells stain for smooth muscle actin, and endothelial cells stain for CD31. Those revealed multiple glomangiomas. Conclusion: A review of Korean literature revealed only one reported cases of disseminated multiple glomus tumors, so this is the second case to be reported in the Korean literature. In case of multiple soft tissue tumors, thorough physical examination and preoperative evaluation is needed.

Correction of Distal Interphalangeal Joint Extension Lag Using Spiral Oblique Retinacular Ligament Reconstruction (나선빗인대 재건을 이용한 원위지관절 신전장애의 교정)

  • Moon, Kyung Hwan;Kim, Jin Soo;Lee, Dong Chul;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.480-484
    • /
    • 2006
  • Purpose: A lot of surgical techniques were tried to correct extension lag of distal interphalangeal joint. Spiral oblique retinacular ligament reconstruction is the one of correction techniques. Methods: From January 2004 to January 2005, a total of 13 extension lag of distal interphalangeal joint corrections were performed using spiral oblique retinacular ligament reconstruction for 11 patients. After dorsal incision exposing from base of distal phalanx to proximal phalanx, the new ligament(half of lateral band or graft tendon) lies distally at the dorsum of the distal phalanx and passes volarly and proximally along the side of the middle phalanx and anterior and obliquely across the front of the proximal interphalangeal joint to the opposite side of the digit at the proximal phalanx. Results: 5 of 6 mallet finger deformities and 7 swan neck deformities were corrected, which were both extension lag of distal interphalangeal joint and hyperextension of proximal interphalangeal joint. Conclusion: As a result, spiral oblique retinacular ligament reconstruction is an effective and recommendable method for correction of mallet finger deformity and swan neck deformity.

Surgical Options for Malignant Skin Tumors of the Hand

  • Yun, Min Ji;Park, Ji Ung;Kwon, Sung Tack
    • Archives of Plastic Surgery
    • /
    • v.40 no.3
    • /
    • pp.238-243
    • /
    • 2013
  • Background Primary malignant tumors of the hand, although unusual, may present varied and often complex clinical problems. The main treatment modality of skin cancer of the hand has changed. Methods We retrospectively reviewed the medical records of 43 patients who underwent surgery for malignant skin tumors of the hand during an 18-year period, from September 1994 to February 2012. The characteristics of the tumor, methods of reconstruction, and long-term results were reviewed. Results We had 43 patients with 27 melanomas, 14 squamous cell carcinomas, and 2 sarcomas. Their ages ranged from 19 to 74 years (mean, $53.4{\pm}14.5$ years), from 46 to 79 years (mean, $59.7{\pm}9.6$ years), and from 15 to 43 years (mean, $29{\pm}19.8$ years), respectively. Thirty-four cases occurred on the fingertip (16 of those cases on the thumb), 5 cases occurred on the palm, and 4 cases on the dorsum of the hand. Amputation was most frequently used in early cases, but recently, tissue-sparing excision has been performed frequently. The incidence of local recurrence was 3 cases and distant metastasis was 1 case, and the 5-year survival rate was 100%, except in 4 cases due to follow-up loss. Conclusions The principles of treatment-to be curative and to preserve function and appearance-are important points. "Preservative surgery" preserves function and cosmesis of the involved finger or hand dorsum or palm. Preservative surgery not only emphasizes less resection and surgery of a smaller scale, but also optimal reconstruction of the soft tissue defect of the digit.

Distribution of Skin Hydration on the Hand while Wearing Latex Gloves and Inner Gloves (라텍스 장갑과 마이크로 파이버 속장갑 착용 시 손의 피부수분도 분포)

  • Roh, Sang-Hyun;Hyun, Cheol-Seung;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.966-976
    • /
    • 2017
  • This study investigated the effects of wearing latex gloves with inner gloves on the skin hydration of the hands. Fifteen young males participated in the following three conditions: bare hand (BH), latex glove (LG), and latex glove with inner glove condition (LGIG) at an air temperature of $28^{\circ}C$ with 50%RH. Subjects typed a book for 120 min. The results were as follows. Skin hydration was greater for LG and LGIG than BH (p<.001), but no difference was found between LG and LGIG. Skin hydration showed greater values on the thenar and dorsum compared to the palm for both LG and LGIG (p<.05). Skin hydration on the thenar increased during the typing for LG and LGIG, but on the dorsum, palm and finger maintained after 40 min typing. There were positive relationships between hand skin hydration and hand temperature (p<.05). Subjects indicated 'much warmer' and 'more humid' for the LG and LGIG compared to the BH (p<.001), but no differences were found between LG and LGIG. In conclusion, wearing inner gloves inside latex gloves did not induce a reduction of skin hydration and hand temperature; however, significant differences were found in all measurements between bare hands and gloved hands.