• Title/Summary/Keyword: Doppler flow velocity

Search Result 329, Processing Time 0.024 seconds

The Effects of Cervical Manipulation on Blood Flow Velocity of Cranial Artery and Pain Level in Cervicogenic Headache Patients

  • Kang, Da-Haeng;Park, Seung-Kyu;Kang, Jeong-Il;An, Chang-Sik;Kim, Yong-Nam;Yoon, Hee-Jong;Koo, Ja-Pung;Chang, Duncan;Lee, Joon-Hee
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.1 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • The purpose of this study was to identify the effects of manipulation on the velocity of cerebral blood flow and level of pain in cervicogeinc headache patients. The velocity of cerebral blood flow of 30 cervicogeinc headache patients(male=15, female=15, age=$24.00{\pm}3.60$) and 33 normal subjects(male=15, female=18, age=$23.27{\pm}3.00$) was compared. The 30 cervicogeinc headache patients were divided into suboccipitalis relaxation group, cervical manipulation group, and placebo group, and each were given different interventions. The velocity of cerebral blood flow and pain level was measured before intervention, and 1, 2, 3 weeks after intervention. The velocity of cerebral blood flow was measured with the Transcranial Doppler(TCD), and pain level was measured with visual analog scale(VAS). Blood flow velocity of middle cerebral artery in cervicogeinc headache patients was slower than those in healthy subjects. Physical therapy intervention did not have significant effect on velocity of cerebral blood flow, but slowly decreased at intervention for pain level increased. The suboccipitalis relaxation group and cervical manipulation group showed significant effect in decreasing pain level compared to the placebo group(p<.05). Directly applied manipulation therapy in the neck area not only has effect on joint of cervical and soft tissue but also on blood vessels and nerves which pass the neck area, and because of those results of manual therapy seems to help recovery.

  • PDF

Determination of Tricuspid Regurgitation Velocity/Pulmonary Artery Flow Velocity Time Integral in Dogs with Pulmonary Hypertension

  • Kim, Seungji;Oh, Dayoung;Lee, Siheon;Hong, Sungkyun;Choi, Mincheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.185-190
    • /
    • 2020
  • This retrospective, echocardiographic study using 144 dogs with clear systolic tricuspid regurgitation on Doppler echocardiography was performed to determine the diagnostic value of the systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral to predict the Doppler estimates of dogs with tricuspid regurgitation pressure gradient compared with other cardiac indices of pulmonary hypertension, and to investigate a cutoff value to select patients with a potentially poor outcome. The systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral increased significantly as the severity of pulmonary hypertension increased and had a correlation coefficient that was analogous to those of other conventional cardiac indices. A cutoff value greater 1.65 provided the best-balanced sensitivity (84%) and specificity (80%) in determining patients with a poor prognosis. In conclusion, the systolic tricuspid regurgitation velocity/pulmonary artery flow velocity time integral is readily obtained using routine echocardiography and could provide a non-invasive, novel, and supplementary index for evaluating dogs with pulmonary hypertension as useful prognostic criteria, particularly in those with advanced pulmonary hypertension.

Transcranial Doppler Ultrasonography Monitoring during Head-up Tilt Test in Patients with Recurrent Syncope and Presyncope (반복적인 실신 및 실신전환자의 기립경사 검사시 경두개 초음파 감시)

  • Cho, Soo-Jin;Lee, Kwang-Ho;Chung, Chin-Sang
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.64-69
    • /
    • 1999
  • Background : Syncope was defined as transient loss of consciousness and postural tone. The mechanisms of changes in cerebral hemodynamics during syncope have not been fully evaluated. Transcranial Doppler Ultrasonography can continuously monitor the changes in cerebral hemodynamics during head-up tilt (HUT). TCD could reveal the different patterns of changes in cerebral hemodynamics during syncope. Syncope without hypotension or bradycardia could be detected by TCD. We investigated the changes in cerebral blood flow velocity during HUT using TCD in 33 patients with a history of recurrent syncope or presyncope of unknown origin. Methods & Results : The positive responses were defined as presyncope or syncope with hypotension, bradycardia, or both. During HUT without isoproterenol infusion, there were a $86{\pm}23%$ drop in DV and a $41{\pm}34%$ drop in SV in 5 patients with positive reponses, and mean changes in those were less than 10% in patients with negative reponses (p=.00, p=.00). During HUT with isoproterenol infusion, TCD showed a $80{\pm}18%$ drop in diastolic velocity in 14 patients with positive reponses, and a $47{\pm}10%$ drop in that in patients with negative reponses (p=.00), however the change in systolic velocity did not differ. TCD showed three patterns during positive responses; loss of all flow, loss of end diastolic flow, and a decrease in diastolic velocity. Loss of consciousness occurred in the patients with loss of all flow or end-diastolic flow during positive reponses. Conclusions : TCD shows different patterns of changes in cerebral hemodynamics during HUT. TCD can be used to investigate the pathophysiology of neurocardiogenic syncope.

  • PDF

Evaluation of Cerebrovascular Reactivity According to Age Using Transcranial Doppler (Transcranial Doppler를 이용한 연령에 따른 뇌혈관 반응성 평가)

  • Lee, Gyu Taek;Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.43-48
    • /
    • 2004
  • Cerebral vasoreactivity is an index of autoregulation of cerebral perfusion, and can be measured using functional images such as Xe CT, SPECT and PET in reponse to hypercapneic stimulus. In order to measure cerebral $CO_2$ vasoreactivity in routine TCD study conveniently and reliably, we devised a method of rebreathing into closed volume of reservoir bag as a hypercapneic stimulus, and applied it to 44 healthy volunteers. As a hypercapneic stimulus, we applied fitting mask connected with closed reservoir bag for about 90 seconds, and mean blood flow velocity(MBFV) and pulsatility index(PI) were evaluated at proximal middle cerebral arteries(MCA) of 50-55 mm depth, before and after the hypercapneic stimulus. Age affected the MFV and PI value showed significant and the MFV was 56.45(SD=9.75)cm/sec, while PI was 0.406(SD=0.089). As age increases the flow velocity decreased significantly whereas PI value increased(P<0.05). The vasoreactvity significantly decreased with age(P<0.05). The decrease of cerebral blood flow quantity and cerebral blood flow velocity is not only because of increase of diameter of cerebrovascular resulting from aging, but the resistance increase of small blood vessel resulting from the increase of PI & RI value is regarded. We suppose that the rebreathing method is a reliable and convenient technique as a hypercapneic stimulus in determining cerebral $CO_2$ vasoreactivity. The rebreathing method could be non-invasive and useful methods in estimation of the cerebrovascular reactivity and could be applied to the basal and follow-up evaluation of the cerebrovascular reserve of the ischemic stroke patients.

  • PDF

The Technique and Normal Values of Transcranial Doppler Ultrasonography(TCD) (Transcranial Doppler Ultrasonography (TCD)의 시행 방법 및 정상치)

  • Sohn, Young Ho
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 1999
  • Transcranial doppler ultrasonography (TCD) is a new, non-invasive and easily applicable method to evaluate cerebral hemodynamics. Last 10 years, its use in Korea has been dramatically expanded, but the qualification of TCD laboratory has yet to be settled. Since duplex sonography is seldom used in Korea, we have to depend totally on TCD to evaluate cerebral hemodynamic changes. Thus, all of the available data from every detectabler cerebral arteries has to be obtained for accurate interpretation of TCD measurements. Moreover, flow direction and wave form should be concerned in addition to the flow velocity. In this article, I present technique to measure the anterior, meddle and posterior cerebral arteries, the internal carotid artery siphon and at cervical level, and the vertebral and the basilar artery, and normal values for these measurements which is essential for the adequate interpretation.

  • PDF

An implementation of the continuous wave doppler system for blood flow measurement using the ultrasound (효율적인 혈류 속도 측정을 위한 연속 초음파 도플러 장치의 구현)

  • 박형재;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.516-519
    • /
    • 2001
  • To diagnose a patient's blood vessel disease, apoplexy, hypertension, arteriosclerosis, the blood velocity is very important. Determining the blood velocity methods using ultrasound are Continuous Doppler System and Pulse Doppler System. In using the Pulse Doppler System, we can obtain the position of blood velocity. But it is more complex hardware than Continuous Doppler System and it has low SNR(signal-noise ratio). So in this study, to obtain a believable information we use the Continuous Pulse Doppler System. Thus system have analog part and digital part. In analog part is composed of ultrasound generating part, the amplifying part to amplify the received signal from ultrasound sensor, the demodulation part to detect blood velocity and the filtering part to remove the noise. In digital part is composed of the A/D conversion part, digital signal processing part, and the communication part to communicate the PC. In this study to implement efficient ultrasound blood velocity measurement system, we can get the patient's blood velocity information in realtime. Thus, It is a useful in the accurate diagnosis with C.T(computered tomography), M.R.I(magnetic resonance imaging).

  • PDF

The comparison between Numerical Computation and Experiment on Fluid Elow in Rectangular Duct (사각덕트내의 유체유동에 관한 수치계산과 실험의 비교)

  • Yoon Young-Hwan;Bae Taeg-Hee;Park Won-Gu
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.71-74
    • /
    • 2002
  • Fluid flow in a rectangular duct system are measured by W laser doppler velocity meter, and also computed by commercial software of STAR-CD for comparison between then First, for a rectangular duct with 90 degree metered elbow, the fluid flow with Reynolds numbs's of 1,508 is predicted by assumption of both laminar and turbulent models. But, even though the Reynolds number is less than 2,300-3,000, the computation by turbulent model is close to the experimental data. Moeover, the computation by turbulent model for Reynolds number of 11,751 also predicts the experimental data satisfactorily. Second, for a rectangular duct with two branch ducts, the ratios between flow rates in the two branches are invariant to Reynolds number according to both of numerical and experimental results.

  • PDF

Investigation on the Turbulent Flow-Field of a Small-size Axial Fan with Different Operating Points (운전점이 다른 소형 축류홴의 난류 유동장 고찰)

  • Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.40-47
    • /
    • 2008
  • The turbulent flow characteristics around a small-size axial fan(SSAF) for a refrigerator are strongly dependent upon the operating points. Four operating points such as $\phi$ =0.1, 0.18, 0.25 and 0.32 were adopted in this study to investigate three-dimensional turbulent flow characteristics around the SSAF by using a fiber-optic type Laser Doppler Anemometer(LDA) system. Downstream mean velocity profiles of the SSAF along the radial distance show that axial and tangential velocity components exist predominantly, except $\phi$ = 0.1, and have a maximum value at $r/R{\fallingdotseq}0.8$, but radial velocity component having a relatively small value only turns flow direction to the outside or the central part of the SSAF. The turbulent intensity shows that the radial component exists most greatly after $r/R{\fallingdotseq}0.5$. Downstream turbulent kinetic energy at $\phi$ = 0.25 and 0.32 together has the largest peak value at $r/R{\fallingdotseq}0.9$.

  • PDF

Changes in Blood Flow Velocity of Middle Cerebral Artery After Stellate Ganglion Block (성상신경절 차단후 중뇌동맥의 혈류 속도 변화)

  • Seo, Young-Sun;Kim, Sung-Hee;Hur, Chul-Ryung;Lee, Kyung-Jin;Lee, Sook-Yeoung;Kim, Chang-Ho;Kim, Chan;Lee, Young-Seok;Lee, Dong-Chul
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.57-62
    • /
    • 1996
  • Stellate ganglion block(SGB) improves cutaneous blood flow of the head and neck region and upper extremity. For this reason, SGB has been performed in neural and circulatory disorders. But there is controversy on the cerebral blood flow regulation by sympathetic innervation. We investigated the hypothesis that cerebral blood flow could be affected by blocking ipsilateral sympathetic innervation of cerebral blood flow could be affected by blocking ipsilateral sympathetic innervation of cerebral vasculature. In 10 volunteers, the blood flow velocity and pulsatility index(PI) of middle cerebral artery(MCA) was measured using Transcranial Doppler Flowmeter, before and 15 minutes after SGB, at block side and opposite side. The blood flow velocity of MCA at block side was increased from $62.60{\pm}7.60$ cm/s to $72.80{\pm}8.01$ cm/s(P<0.01) and the PI at block side decreased from $0.75{\pm}0.12$ to $0.60{\pm}0.11$(P<0.05). But the blood flow velocity and PI at opposite side did not change. This study demonstrated that the cerebral blood flow could be increased by SGB, the preganglionic nerve fibers of which synapse with other cervical sympathetic ganglions.

  • PDF