• Title/Summary/Keyword: Doppler flow velocity

Search Result 328, Processing Time 0.021 seconds

A Study on the Flow Characteristics of Developing Transitional Steady Flows in a Curved Duct by Using Laser Doppler Velocimeter (I) (곡관덕트에서 LDV를 이용한 천이정상유동의 유동특성에 관한 연구(I))

  • 봉태근;박길문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.96-101
    • /
    • 2000
  • In this paper, an experimental investigation of characteristics of developing transitional steady flows in a square-sectional 180 urved duct is presented. The experimental study is carried out to measure axial velocity profiles by using Laser Doppler Velocimeter (LDV) system. The flow development is found to depend upon Dean number and curvature ratio. For transitional steady flows, the maximum velocity position of axial velocity profiles begins to incline toward the outer wall from $\phi$=$30^{\circ}$bended angle, velocity profiles in center of the duct have lower value than those of the inner and outer walls because of the centrifugal forces.

  • PDF

Velocity Measurement in a Rectangular Duct with $90^{\circ}$ Mitered Elbow (직각 엘보우를 가진 사각덕트 내의 유속측정에 관한 연구)

  • 윤영환;배택희;박원구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1184-1195
    • /
    • 2001
  • Analysis of fluid flow in rectangular ducts has been conducted since it has a wide application. The purpose is to provide experimental data for the comparison with computational results. Velocity distributions inside a rectangular duct with $90^{\circ}$ mitered elbow are measured by 5W laser doppler velocity meter for Reynolds numbers of 4,049, 8,104, and 12,186. Flow rates obtained by the integration of measured velocity profile at three cross-sections, which are inlet, middle section after the elbow, and outlet, have errors less than 0.9% among them. Turbulent fluctuation components in two directions are found to have almost similar magnitude each other at a certain location due to the isotropic characteristic of turbulence.

  • PDF

Blood flow velocity in the anterior humeral circumflex artery and tear size can predict synovitis severity in patients with rotator cuff tears

  • Takahiro Machida;Takahiko Hirooka;Akihisa Watanabe;Hinako Katayama;Yuki Matsukubo
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.11-17
    • /
    • 2024
  • Background: Rotator cuff tears are often associated with synovitis, but the ability of noninvasive ultrasonography to predict the severity of synovitis remains unclear. We investigated whether ultrasound parameters, namely peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, reflect synovitis severity. Methods: A total of 54 patients undergoing arthroscopic rotator cuff repair were selected. Doppler ultrasound was used to measure peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, and these values were compared with the intraoperative synovitis score in univariate and multivariate analyses. Results: Univariate analyses revealed that tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the glenohumeral joint were associated with synovitis in the glenohumeral joint (P=0.02, P<0.001, P=0.02, respectively). In the subacromial space, tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the subacromial space were associated with synovitis severity (P=0.02, P<0.001, P=0.02, respectively). Multivariate analyses indicated that tear size and peak systolic velocity in the anterior humeral circumflex artery were independently associated with synovitis scores in both the glenohumeral joint and the subacromial space (all P<0.05). Conclusions: These findings demonstrate that tear size and peak systolic velocity in the anterior humeral circumflex artery, which can both be measured noninvasively, are useful indicators of synovitis severity.

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Experimental Study on the relationship between Cerebral blood vessel with Meridian by using Transcranial Doppler (TCD(Transcranial Doppler Ultrasonography)를 이용한 뇌혈관(腦血管)과 경락(經絡) 관계 연구(硏究))

  • Kyung, Hyuk-su;Kim, Dong-jo;Yoo, Hee-jeong;Kim, Ki-tae;Kong, Kyung-hwan;Lee, Tae-ho
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.6 no.1
    • /
    • pp.45-53
    • /
    • 2005
  • Objective : This study was performed to examine the relationship between cerebral blood vessel with meridian by using Transcranial Doppler Ultrasonography(TCD) Method : Monitoring of TCD was examined in 10 healthy people in their twenties (mean age was 26.5±1.00). Each examination was performed before & after acupuncture. Three Meridian were tested. Those were Stomach Meridian, Bladder Meridian & Gallbladder Meridian. Maximum velocity and Mean velocity were analyzed from TCD on different vessel. Result : The results showed significant(p<0.05; Wilcoxon signed rank test) change in some cerebral blood flow after acupuncture. Conclusion : There was the relationship between Meridian and cerebral blood vessel.

  • PDF

A Study on the Multigate Pulsed Doppler System. (다중 채널 펄스 도플러 장치에 관한 연구)

  • 김병철;박세현
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.75-79
    • /
    • 1986
  • In this paper, a multigate pulsed doppler system with parallel signal processing which enables the transcutaneous assesment of the blood-flow velocities of five adjacent sample volumes is developed. The outputs of the system are audio signals, velocity curves and velocity profiles of 5 adjacent sample volumes. We have applied to the major superficial arteries and obtained the detailed information about the time dependent blood-flow behavior.

  • PDF

Fluidic velocity sensing with a speaker based optical doppler tomography (유속 센싱을 위한 스피커형 광학적 유체 단층촬영 기술)

  • Lee, Chang-Ho;Kim, Jee-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.317-324
    • /
    • 2008
  • This paper presents an optical doppler tomography(ODT) system using a speaker as a method to achieve depth measurement in a flowing sample. The use of the speaker provides easy implementation with a low cost. The nonlinear characteristics of the speaker has hindered its adaptation because it produces inconsistent fringe frequencies at different depths. This paper reports an adaptive algorithm to compensate the nonlinear characteristics, and could, resultantly, acquire the Doppler frequency shift caused by the sample. The experiment utilizes a flowing scattering particle solution in a capillary tube at a certain flow rate. The Doppler frequency profile over the lumen was calculated by using spectrogram method. and we obtained the velocity image of the sample.

Color Doppler Flow Mapping of a Moving Orifice: Proximal Flow Convergence (운동입구에서의 컬러도플러유동매핑: 근위유동수렴)

  • Kim, Young-H.;Yoganathan, Ajit P.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.39-42
    • /
    • 1992
  • Color Doppler flow mapping (CDFM) was performed on an $\underline{in\;vitro}$ experimental setup with a regurgitant moving orifice using the proximal isovelocity surface area (PISA) technique. PISA flow rates underestimated actual flow rates by as much as 65%, which is very important in diagnosing patients with valvular regurgitations or stenosis. The correction factor considering the velocity of the orifice improved the PISA flow rates.

  • PDF

LDV Measurement for the Mixing Effect of the Rotator Shape in a Confined Cylinder (밀폐된 원통내부에서 회전체의 형상에 따른 혼합효과에 대한 LDV 측정)

  • Park, Cheon-Soo;Kim, You-Gon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.720-726
    • /
    • 2001
  • Two-dimensional, angle-resolved LDV(Laser Doppler Velocimetry) measurements of the turbulent rotating flow field in a confined cylinder have been performed. The configurations of interest are flows between a rotating upper disk with a rod attached by a disk or impeller(${\theta}= 90^{\circ},\;45^{\circ}$) and a stationary lower disk in a confined cylinder. The mean flow velocity as well as the turbulent intensity of the flow field have been measured. The results show that the flow is strongly dependent on the position of the impellers or the disk, negligibly affected by the Reynolds number in turbulent flow. It is observed that the mixing effect of the axial flow impeller(${\theta}= 45^{\circ}$) is better than that of the radial flow impeller(${\theta}= 90^{\circ}$) or a disk.

  • PDF

Clinical study on the estimation of blood flow velocity using doppler ultrasound of the cerebral artery in stroke patients (도플러 초음파를 이용한 중풍환자(中風患者)의 뇌혈관(腦血管) 혈류측정(血流測定)에 관한 임상적(臨床的) 연구(硏究) (경동맥(頸動脈), 추골동맥(椎骨動脈) 및 기저동맥(基底動脈)을 중심으로))

  • Chang, In-Su;Sun, Jungn-Ki
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.345-360
    • /
    • 1996
  • Background and Purpose: To evaluate the blood flow velocity using doppler ultrasound of the carotid artery, vertebral artery, and basilar artery in stroke patients Material and Methods: To evaluate the blood flow, I measured the peak systolic velocity and mean velocity of the common carotid artery(CCA), internal carotid artery(ICA), external carotid artery (ECA). vertebral artery(VA), and basilar artery(BA) in 44 stroke patients and 15 healthy adults. To investigate the difference between ischemic stroke patients and normal healthy adults, I selected 44 ischemic stroke patients diagnosed by brain CT and brain MRI, and 15 healthy adults who did not have any symptoms of stroke, hypertension, heart disease, and diabetes melitus. Results: Peak velocity in normal adults was 50.6${\pm}$1.6cm/sec in the CCA, 67.2${\pm}$1.7cm/sec in the ICA, 62.5${\pm}$2.4cm/see in the ECA, 45.5${\pm}$1.9cm/sec VA. and 50.5${\pm}$3.5cm/sec in the BA. Mean velocity in normal adults was 26.9${\pm}$1.1cm/sec in the CCA, 43.7${\pm}$1.4cm/sec in the ICA, 26.7${\pm}$1.3cm/sec in the ECA. 31.6${\pm}$1.9cm/sec in the VA and 33.0${\pm}$2.6cm/sec in the BA. In this study, there was a significant increase in the velocity of ICA, ECA, and VA of ischemic stroke patients in comparison with normal healthy adults. And the blood flow velocity of this study in the CCA and ECA was different from other reported foreign values and the other known values in my country. Conclusion: There was a significant difference in the blood flow velocity between ischemic stroke patients and normal healthy adults. And the blood flow velocity of this study was different from other reported foreign values and the other known values in my country. Therefore, it needs more detailed studies about old aged Korean and ischemic stroke patients than previous studies.

  • PDF