• Title/Summary/Keyword: Domestic Gas Boiler

Search Result 36, Processing Time 0.025 seconds

Part Load Performance Characteristics of Domestic Wood Pellet Boiler (가정용 목재 펠릿 보일러에 대한 부분부하 운전 특성)

  • Kang, Sae Byul;Kim, Jong Jin;Kim, Hyouck Ju;Park, Hwa Choon;Choi, Kyu Sung;Sim, Bong Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.103.1-103.1
    • /
    • 2010
  • Recently domestic wood pellet boilers are installed in rural and forestry houses. The fuel price per lower heating value of wood pellet is about 20 % lower than that of heating oil on July 2010. In spite of lower price of wood pellet, a few user of wood pellet boiler complain expensive fuel cost. One of this reason is inaccurate or improper air-fuel ratio setting of wood pellet boiler. O2 concentration of flue gas of domestic wood pellet boiler is about 9.7 % and there are few domestic wood pellet boiler which can control air-fuel ratio automatically. We tested a domestic wood pellet boiler in changing boiler thermal output and air-fuel ratio. The nominal boiler thermal output is 25 kW (21 500 kcal/h). We measured thermal efficiency and flue gas concentrations such as CO and NOx at each boiler thermal load with various air-fuel ratio. The results show that if air flow rate is the same as full load and part load, thermal efficiency of part load of 40 % drops about 7.7 %p compared to boiler full load case.

  • PDF

A Study on the Control of the Exhaust CO from Gas Boiler (가스보일러 일산화탄소 제어에 관한 연구)

  • Jo Young-Do;Choi Kyoung-Suhk;Kim Ji-Yoon;Kim Chang-Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.7-14
    • /
    • 2001
  • In this work, the chemical composition of the exhaust gas from domestic gas boiler has been analysed in the point of thermodynamics and CO sensor has been characterized. We proposed that the combustion condition can be estimated by the exhaust gas composition, i.e., the excess air ratio and combustion temperature can be calculated simply by the measurement of the $O_{2}$ fraction and $H_{2}/CO$ in the exhaust gas. By analyse the on site situation domestic boiler, the excess air ratio is about $55\~110\%$. Therefore, the CO may be produced in domestic gas boiler by luminous(yellow) flames rapidly lose heat by radiation, turbulent flames may be partially quenched by the action of steep velocity gradients, and flames burning very close to a cold wall may be partial1y quenched by heat conductivity to the wall. The output voltage of CO sensor is lineally depend on the CO and $H_{2}$concentration. And the exhaust CO from boiler can be reduced by closed loop control with CO sensor

  • PDF

Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler (가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

An Economic Analysis for the Domestic Natural Gas Demand Side Management : Case Study in Introducing the High Efficiency Gas Boiler (국내 천연가스 수요관리의 경제성 분석: 고효율 가스보일러 도입 사례연구)

  • 김봉진;이장우;박수억;박연홍
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • We consider the economic analysis of the domestic natural gas DSM (Demand Side Management). Since the demand of the domestic natural gas decreases in the summer and dramatically increases in the winter, the necessity of the DSM that will smooth the demand pattern of the natural gas is emerged. The economic analysis of the DSM program is used as a main tool for screening the DSM. This paper suggests an economic evaluation method for the domestic gas DSM from the perspectives of participants, Korea Gas Corporation, local distribution company, non-participants, and total resource. The high-efficiency gas boiler is selected as a case study to illustrate the economic analysis of the natural gas DSM.

  • PDF

Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions (국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석)

  • Yu, Byeong Ho;Seo, Byeong-Mo;Moon, Jin-Woo;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.

Numerical Analysis of Combustion and Heat Transfer of Domestic Gas Boiler Equipped with 2-stage Heat Exchanger (수치해법을 이용한 2단 열교환기 장착 가정용 보일러 연소실의 연소 및 열전달 특성 해석)

  • Kang, Seung-Kyu;Choi, Kyoung-Suhk;Kwon, Jeong-Rack
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.1-6
    • /
    • 2010
  • In this work, a numerical investigation is performed for the combustion chamber of domestic gas boiler with 1-stage and 2-stage heat exchangers. The fluid flow and heat transfer performance is simulated with a structure change of heat exchanger. The numerical solution shows that the heat transfer of the 2-stage heat exchanger is about 24% higher than that of the 1-stage heat exchanger, while the pressure loss of the 2-stage heat exchanger increases. The temperature of combustion chamber with 2-stage heat exchanger is lower than that of 1-stage. This effect reduces thermal NOx with decrease of high temperature staying time of the combustion gas.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

Study on the Suppression of Sulfur Trioxide in High Sulfur Boiler (고유황 보일러에서의 Sulfur Trioxide의 억제에 대한 연구)

  • Choi, Sung-Bu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.455-463
    • /
    • 2011
  • The average sulfur content of crude oil is 2.2%. Coal is about 0.3 to 4.0 percent of the sulfur gases or particles being discharged into the atmosphere through the chimney as 1 to 2% $SO_3$(Sulfur trioxide) and about 95% of the $SO_2$ is reported. $SO_3$ gas, which has many different causes of, as the combustion of sulfur containing fuel during the air due to the excess $SO_2$ gas is oxidized to $SO_3$ gas. Sulfur trioxide emitted from high sulfur heavy oil fired boiler caused white plume in stack and high temperature and cold end corrosion of facilities. So, in order to control sulfur trioxide concentration of Fuel gas in boiler, various of additives are used in other foreign. They are injected to Fuel Oil and consumed in boiler and reduce ash and the conversion rate of sulfur trioxide. In domestic, MgO compounds are used as additives but the total volume of them are made from other foreign company. In this study, MgO compounds were developed with liquid MgO compounds and field application was accomplished. The effect of newly developed chemicals and process were nearly equal to foreign products. In Consequent, the chemicals and process produced by newly developed technology can be substituted for foreign products and reduce the cost of plant operation.

An Empirical Study on the Repair Rate of Domestic Gas Boiler within Warranty Period(I) (가정용(家庭用) 가스 보일러의 보증기간내(保證期間內) 수리율(修理率)에 관(關)한 실증적(實證的) 연구(硏究)(I))

  • Han, Jae-Hoon;Kim, Bong-Sun
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.1
    • /
    • pp.139-146
    • /
    • 2014
  • As Crosby notes, the most companies spend 15 to 20% of their sales dollars on quality costs. Generally the most effective way to manage quality costs is to avoid having defects in the first place. In this paper we have studied about the repair(service) problem of domestic gas boiler within warranty period. We develop a system, which man could find the cause of the problem at an early stage and could devise a countermove to the problem under supposing that the service(repair) rate follows exponential distribution and the product is manufactured lot-for-lot continually. Using the developed early sensing system. it is expected to improve the reliability of the product, to save expenses of company and to improve customer's satisfaction. And the system will be expended to incorporate information technology, which can detect the repair rate automatically.