• 제목/요약/키워드: Domestic Gas Boiler

검색결과 36건 처리시간 0.023초

가정용 목재 펠릿 보일러에 대한 부분부하 운전 특성 (Part Load Performance Characteristics of Domestic Wood Pellet Boiler)

  • 강새별;김종진;김혁주;박화춘;최규성;심봉석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.103.1-103.1
    • /
    • 2010
  • Recently domestic wood pellet boilers are installed in rural and forestry houses. The fuel price per lower heating value of wood pellet is about 20 % lower than that of heating oil on July 2010. In spite of lower price of wood pellet, a few user of wood pellet boiler complain expensive fuel cost. One of this reason is inaccurate or improper air-fuel ratio setting of wood pellet boiler. O2 concentration of flue gas of domestic wood pellet boiler is about 9.7 % and there are few domestic wood pellet boiler which can control air-fuel ratio automatically. We tested a domestic wood pellet boiler in changing boiler thermal output and air-fuel ratio. The nominal boiler thermal output is 25 kW (21 500 kcal/h). We measured thermal efficiency and flue gas concentrations such as CO and NOx at each boiler thermal load with various air-fuel ratio. The results show that if air flow rate is the same as full load and part load, thermal efficiency of part load of 40 % drops about 7.7 %p compared to boiler full load case.

  • PDF

가스보일러 일산화탄소 제어에 관한 연구 (A Study on the Control of the Exhaust CO from Gas Boiler)

  • 조영도;최경석;김지윤;깅창연
    • 한국가스학회지
    • /
    • 제5권1호
    • /
    • pp.7-14
    • /
    • 2001
  • 가정집 가스보일러 배기가스 조성에 대하여 열역학적 관점에서 해석하였고 일산화탄소 센서의 특성에 대하여 고찰하였다. 배기가스의 조성 측정으로부터 보일러 연소조건을 예측할 수 있음을 본 연구에서 제시하였다. 즉 배기가스중의 산소농도로부터 과잉 공기량을 예측할 수 있고, 배기가스중의 일산화탄소와 수소의 비율로부터 보일러 연소실 온도를 알 수 있다. 가정집에 설치되어 있는 보일러의 배기가스 조성 해석으로부터 과잉 공기량이 약 $55\~110\%$임을 알 수 있었다. 따라서 가정집 가스보일러에서 발생하는 일산화탄소는 연소가스의 유속구배에 의한 난류에 의한 국부냉각 또는 벽에 의한 국부냉각으로 등에 의하여 발생하는 것으로 사료된다. CO센서의 출력전압은 수소와 일산화탄소의 농도에 선형적으로 비례하며, 보일러에서 일산화탄소 발생을 CO센서와 연동제어로 감소시킬 수 있다.

  • PDF

가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석 (Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler)

  • 강승규;최경석;윤준용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2868-2873
    • /
    • 2008
  • Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.

  • PDF

국내 천연가스 수요관리의 경제성 분석: 고효율 가스보일러 도입 사례연구 (An Economic Analysis for the Domestic Natural Gas Demand Side Management : Case Study in Introducing the High Efficiency Gas Boiler)

  • 김봉진;이장우;박수억;박연홍
    • 에너지공학
    • /
    • 제7권1호
    • /
    • pp.1-6
    • /
    • 1998
  • 본 연구는 국내 천연가스 수요관리 사업의 경제성 분석 방법을 다룬다. 국내 천연가스 수요는 하절기에 감소하고 동절기에 급증함에 따라, 이러한 수요 형태를 완화할 수 있는 천연가스 수요관리의 필요성이 대두되고 있다. 천연가스 수요관리 사업의 경제성 분석 결과는 해당 수요관리 사업의 추진 여부를 결정하는 주요 도구로 사용된다. 본 연구에서는 국내 천연가스 산업의 이원화된 공급구조를 감안하여 수요관리 사업의 참여자, 한국가스공사, 도시가스회사, 비참여자, 총자원 등 각 이해 당사자의 입장에서 천연가스 수요관리의 경제성 분석 방법을 제시하였다. 사례연구로는 향후 대표적인 에너지절약 사업이 될 것으로 예상되는 고효율 가스 보일러에 대한 경제성 분석을 하였다.

  • PDF

국내 기상조건하 주거용 건물 가스 보일러의 부분부하 특성과 에너지 사용량 분석 (Analysis of the Part Load Ratio Characteristics and Gas Energy Consumption of a Hot Water Boiler in a Residential Building under Korean Climatic Conditions)

  • 유병호;서병모;문진우;이광호
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.455-462
    • /
    • 2015
  • Residential buildings account for a significant portion of the total building-energy usage in Korea, and a variety of research studies on the domestic boiler have therefore been carried out; however, most of these studies examined the boiler itself, whereby the part-load ratio characteristics and the corresponding gas-energy consumption patterns were not analyzed. In this study, the part-load ratio and operating characteristics of a domestic gas boiler were analyzed within a residential building equipped with a radiant floor-heating system; in addition, the energy consumption between condensing and conventional boilers was comparatively analyzed. Our results show that significant portions of the total operating hours, heating load, and energy consumption are in the part-load ratio range of 0 through 40%, whereby the energy consumption was significantly affected by the boiler efficiency under low part-load conditions. These results indicate that the part-load operation of a boiler is an important factor in residential buildings; furthermore, replacing a conventional boiler with a condensing boiler can reduce annual gas-energy usage by more than 20%.

수치해법을 이용한 2단 열교환기 장착 가정용 보일러 연소실의 연소 및 열전달 특성 해석 (Numerical Analysis of Combustion and Heat Transfer of Domestic Gas Boiler Equipped with 2-stage Heat Exchanger)

  • 강승규;최경석;권정락
    • 한국가스학회지
    • /
    • 제14권5호
    • /
    • pp.1-6
    • /
    • 2010
  • 본 연구는 가정용 보일러의 연소실 전산유동해석을 통해 연소실 내부의 온도분포 및 유동형태를 해석하였다. 전산해석을 통해 연소실의 열교환기 구조변화에 따른 효율향상 및 배기가스 발생 특성을 예측하였다. 2단 열교환기 장착시 연소실 내부의 온도를 하강시킴으로서 연소가스의 고온영역 체류시간 감소로 Thermal NOx의 생성이 억제되어 NOx의 발생량이 감소할 것으로 예측되었다. 효율면에서는 2단 열교환기 장착 시 1단 열교환기에 비해 약 24%의 효율이 상승하였다. 반면에 2단 열교환기 장착 시 약 10%의 압력손실이 증가하는 것으로 확인되었다.

70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발 (A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW)

  • 박찬일;김래현
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.73-82
    • /
    • 2016
  • 표시가스 소비량이 70 kW 이하인 가정용 가스보일러에 대하여 여러 가지 운전조건하의 에너지 소비효율 측정에 대해 고찰하였다. 실제 운전상태와 유사한 실험조건에서 행한 에너지 효율실험 결과를 국내의 효율등급표시 실험방법 결과와 비교 분석하였다. 실험에 사용된 가정용가스보일러는 일반보일러와 콘덴싱 보일러 각 1개씩이며, 각각의 보일러에 대하여 네 가지 조건으로 실험하였다. 실험종류를 구분하면 실험실 모드와 실제 가동모드로 나누고, 각각의 모드별로 최대가스소비량 상태와 소비자판매 상태로 나누어 적용하였다. 효율실험을 위해 사용하는 장비는 KS 표준과 유럽의 EN 규격 등 가스보일러 관련 규격에서 제시하는 실험장치의 기능을 다하면서, 여러 가지 측정 인자를 지속적으로 축적, 기록 및 저장할 수 있는 장치로 하였다. 측정 대상 인자들은 유량(가스, 물), 온도(실험실, 난방공급수, 난방환수, 배기가스), 압력(가스미터 내부, 가스보일러 입구, 대기압) 등이다. 위 네 가지 모드의 실험결과 에너지소비효율은 실험실 상태(보일러의 안정화 상태로 실험 시작)로 실험할 때가 실제 소비자가 사용하는 패턴으로 실험할 때 보다 일반보일러의 경우 약 10 %, 콘덴싱 보일러의 경우 약 20% 높은 소비효율로 측정되었다. 에너지소비효율등급을 부여하는 정부 고시의 효율실험방법도 본 연구에서 실시한 것과 같이 실제상황을 가정한 효율실험방법을 도입 운영할 필요가 있다.

고유황 보일러에서의 Sulfur Trioxide의 억제에 대한 연구 (Study on the Suppression of Sulfur Trioxide in High Sulfur Boiler)

  • 최성부
    • 한국응용과학기술학회지
    • /
    • 제28권4호
    • /
    • pp.455-463
    • /
    • 2011
  • The average sulfur content of crude oil is 2.2%. Coal is about 0.3 to 4.0 percent of the sulfur gases or particles being discharged into the atmosphere through the chimney as 1 to 2% $SO_3$(Sulfur trioxide) and about 95% of the $SO_2$ is reported. $SO_3$ gas, which has many different causes of, as the combustion of sulfur containing fuel during the air due to the excess $SO_2$ gas is oxidized to $SO_3$ gas. Sulfur trioxide emitted from high sulfur heavy oil fired boiler caused white plume in stack and high temperature and cold end corrosion of facilities. So, in order to control sulfur trioxide concentration of Fuel gas in boiler, various of additives are used in other foreign. They are injected to Fuel Oil and consumed in boiler and reduce ash and the conversion rate of sulfur trioxide. In domestic, MgO compounds are used as additives but the total volume of them are made from other foreign company. In this study, MgO compounds were developed with liquid MgO compounds and field application was accomplished. The effect of newly developed chemicals and process were nearly equal to foreign products. In Consequent, the chemicals and process produced by newly developed technology can be substituted for foreign products and reduce the cost of plant operation.

가정용(家庭用) 가스 보일러의 보증기간내(保證期間內) 수리율(修理率)에 관(關)한 실증적(實證的) 연구(硏究)(I) (An Empirical Study on the Repair Rate of Domestic Gas Boiler within Warranty Period(I))

  • 한재훈;김봉선
    • 대한안전경영과학회지
    • /
    • 제16권1호
    • /
    • pp.139-146
    • /
    • 2014
  • As Crosby notes, the most companies spend 15 to 20% of their sales dollars on quality costs. Generally the most effective way to manage quality costs is to avoid having defects in the first place. In this paper we have studied about the repair(service) problem of domestic gas boiler within warranty period. We develop a system, which man could find the cause of the problem at an early stage and could devise a countermove to the problem under supposing that the service(repair) rate follows exponential distribution and the product is manufactured lot-for-lot continually. Using the developed early sensing system. it is expected to improve the reliability of the product, to save expenses of company and to improve customer's satisfaction. And the system will be expended to incorporate information technology, which can detect the repair rate automatically.