• Title/Summary/Keyword: Dog-bone

Search Result 294, Processing Time 0.025 seconds

Experimental investigation on the behaviour of UHPC-steel composite slabs under hogging moment

  • Gao, Xiao-Long;Wang, Jun-Yan;Bian, Chen;Xiao, Ru-Cheng;Ma, Biao
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.765-777
    • /
    • 2022
  • Ultra high performance concrete (UHPC) can be used in the UHPC-steel composite structures especially for bridge structures to achieve high stiffness and high fatigue resistance with low self-weight. The structural performances of UHPC-steel composite slabs subjected to hogging moment have a significant influence on the global stiffness and durability of UHPC-steel composite structures. In order to study the structural behaviors of non-steam-cured UHPC-steel composite slabs subjected to negative moment, five composite slabs combined the thin UHPC layers to steel plates via shear stud connecters with the diameter of 16mm were fabricated and tested under negative moment. The test program aimed to investigate the effect of stud spacing and longitudinal reinforcement ratios on the failure mode, load-deflection behaviors, cracking patterns, bond-slips, and carrying capacities of composite slabs subjected to negative moment. In addition, direct tensile tests for the dog-bone UHPC specimens with longitudinal reinforcement bars were carried out to study the effect of reinforcement bars on the tensile strength of UHPC in the thin structure members. Based on the experimental results, analytical models were also developed to predict the cracking load and ultimate load of UHPC-steel composite slabs subjected to negative moment.

Studies on seismic performance of the new section steel beam-wall connection joint

  • Weicheng Su;Jian Liu;Changjiang Liu;Chiyu Luo;Weihua Ye;Yaojun Deng
    • Structural Engineering and Mechanics
    • /
    • v.88 no.5
    • /
    • pp.501-519
    • /
    • 2023
  • This paper introduces a new hybrid structural connection joint that combines shear walls with section steel beams, fundamentally resolving the construction complexity issue of requiring pre-embedded connectors in the connection between shear walls and steel beams. Initially, a quasi-static loading scheme with load-deformation dual control was employed to conduct low-cycle repeated loading experiments on five new connection joints. Data was acquired using displacement and strain gauges to compare the energy dissipation coefficients of each specimen. The destruction process of the new connection joints was meticulously observed and recorded, delineating it into three stages. Hysteresis curves and skeleton curves of the joint specimens were plotted based on experimental results, summarizing the energy dissipation performance of the joints. It's noteworthy that the addition of shear walls led to an approximate 17% increase in the energy dissipation coefficient. The energy dissipation coefficients of dog-bone-shaped connection joints with shear walls and cover plates reached 2.043 and 2.059, respectively, exhibiting the most comprehensive hysteresis curves. Additionally, the impact of laminated steel plates covering composite concrete floors on the stiffness of semi-rigid joint ends under excessive stretching should not be disregarded. A comparison with finite element analysis results yielded an error of merely 2.2%, offering substantial evidence for the wide-ranging application prospects of this innovative joint in seismic performance.

Effect of Nandrolone Decanoate on Disuse Muscle Atrophy and Bone Beating in Dogs (개에서 불용성 근위축과 골절 치유에 대한 Nandrolone decanoate의 효과)

  • Yun Seong-jin;Lim Ji-hey;Rahman Md. Mizanur;Byeon Ye-eun;Kim Wan-hee;Kweon Oh-kyeong
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.336-341
    • /
    • 2005
  • Anabolic steroid compounds are widely used for the increase of muscle mass, density of bone and athletic ability. The present study conducted to evaluate the effects of nandrolone decanoate (ND), one of the anabolic steroid compounds, on disuse muscle atrophy and healing process of bone in dogs. Twenty physically healthy dogs of both sexes were used in this experiment and divided into three groups: group A (control), group B (low dose M-1.5 mg/kg) and group C (high dose ND-7.5 mg/kg). One-mm strip of full thickness bone was excised from the radius below the pronator teres muscle for the artificial fracture and then the fractured ends were fixed in apposition with bone plate leaving 1mm gap, and finally immobilized externally by Robert John's bandage for 4 weeks. ND was administered intramuscularly once a week far 8 weeks. Body weight, muscle mass change and fracture gap of the bone were evaluated immediately after surgery, and 2, 4, and 8 weeks after surgery. The rates of muscle mass change 8 weeks after surgery were $-2.75\pm0.16\%,\;1.68\pm0.11\%\;and\;1.74\pm0.48\%$ in groups A, B and C, respectively. The significant increase (p<0.05) of muscle mass increments were found in the treated groups. The fibrous connective tissue layer in the fracture gaps of the treated groups increased more than the control, especially in the group C at 4th week. More dense fibrous connective tissue were found in the treated groups at 8th week. Collectively, our results suggested that ND was an effective anabolic agent for the immobilized disuse muscle and bone healing.

THE ONSET OF ANKYLOSIS FOLLOWING INTRUSIVE LUXATION INJURIES (외상성 intrusion 치아의 교정적 견인시기에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Turley, Patrick-K.
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.259-272
    • /
    • 1991
  • Orthodontic traction has been suggested as the treatment of choice for intrusive luxation injuries. Prior research has shown orthodontic forces to be ineffective in the presence of ankylosis or in cases with zero mobility following the injury. If orthodontic traction is to be effective, it must be initiated prior to the onset of ankylosis. The purpose of this study was to describe the effects of intrusive luxation at various times following the injury, and to determine the time of the onset of ankylosis, and to examine what effect immediate partial luxation has on the onset of ankylosis. Eight young mongrel dogs were utilized for this study. Intrusive luxation was produced with an axial impact using a gravity hammer and a specially designed holding device on 4 teeth (2 max. and 2 man. first premolars) in each dog. The teeth were intruded approximately 3-4mm in an axial direction. One maxillary and one mandibular premolars were partially luxated with the other two teeth being untouched. Pre and posttrauma tooth position was documented with plaster models and radiographs taken with an individualized X-ray jig. Dogs were sacrificed immediately following the injury and at 1, 2, 4, 7, 10, 14 and 21 days respectively. Tetracycline was administered as a vital bone marker 24 hours before sacrifice. Block sections of the tooth and alveolus were prepared for decalcified and non decalcified histologic sections. The effects of traumatic intrusion were analyzed by means of model casts, radiographs, tetracycline bone marking and histologic preparations. The results obtained were as follows: 1. The animal sacrificed immediately following the injury displayed alveolar fractures, torn periodontal ligaments, and areas of direct tooth-bone contact. 2. The odontoblastic layer of the pulp was disorganized as early as 24 hours after the injury. 3. Bony remodeling was noted at 4 days along with active surface resorption. 4. Ankylosis was first seen 7 days after the injury. 5. Osteogenesis in the dentin (thick tetracycline bands) was observed 7 days after the injury. 6. There was no progressive root resorption and ankylosis where the periodontal ligament has been healed. 7. The Luxated group showed significantly more root resolution and ankylosis than the Nonluxated group with increased observation periods. The results suggest that ankylosis may occur within the first week following the injury, and hence orthodontic traction should be initiated as soon after the injury as possible.

  • PDF

Effect of extraction socket granulation tissue graft on the regeneration of horizontal furcation defect (발치와의 육아조직 이식이 치근이개 결손부의 재생에 미치는 영향)

  • Oh, Mok-Hoon;Han, Soo-Boo;Son, Sung-Heui;Yang, Seung-Min;Ko, Jae-Seung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.735-751
    • /
    • 1996
  • An ultimate goal of periodontal therapy is to stop the disease process and to regenerate a functionally-oriented periodontium destroyed as a result of periodontal disease. The purpose of this study was to observe the effect of grafting granulation tissue obtained from extraction socket on the regeneration of horizontal furcation defect. Six dogs were used in this study. All mandibular first and third premolars were extracted. At 2, 3, and 5 days after extraction, tissues were obtained from extraction socket of 1 mongrel dog and examined by light microscope. Granulation tissue obtained at 5 days after extraction was chosen as the graft material. Five days later, horizontal furcation defects were created surgically at mandibular second and fourth premolars in the right and left side of the 5 beagle dogs. The entrance area of the artificially prepared "key hole" defects were about $3\;4mm^2$. By random selections, 2 exposed furcation defects were grafted with granulation tissue obtained from extraction socket as experimental group and 1 furcation defect was as control. The flaps were replaced to their original position and sutured with 4-0 chromic cat-gut. Three dogs were sacrificed 4 weeks and two dogs 8 weeks after surgery, and the prepared specimens were examined by light microscope. At 4 weeks, furcations were filled with epithelial lining and fibrous connective tissue infiltrated with chronic inflammatory cells. New bone formation was observed in all groups. Only experimental group showed new cementum formation. At 8 weeks, new cementum, functional arrangement of new PDL fiber, root resorption, and some ankylotic union of newly formed alveolar bone and root surface were observed in all groups. Experimental group showed that epithelial downgrowth was inhibited and new bone formation was more active compared to control. The success rate of the furcation defect healing was higher in experimental group than control. These results suggested that grafting of granulation tissue obtained from extraction socket which combined with reconstructive periodontal flap surgery may promote periodontal regeneration of horizontal furcation defect.

  • PDF

Effect of Korean Soup(Tang) upon Customers Royalty in the Food Service Industry in Korea (외식급식산업에 있어서 국(탕)이 고객 충성도에 미치는 영향)

  • 이영남;노성윤
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.13 no.5
    • /
    • pp.482-493
    • /
    • 2003
  • This study has been designed to stress the thoughts that soups should be offered taking into account customer's preference aimed at leading to eventual customer's satisfaction and the importance that Korean traditional food should take the lead in shifting dining-out industry's paradigm to customer-orientation instead of product-orientation. From August 15 through August 30, 2003, the drawn-up questionnaires were handed out to 500 numbers of adults aged over 20 living in Seoul, metropolitan city of Korea and the finally collected 361 questionnaires from them have been analysed as a subject for this study. It showed that the male respondents(44%) dined out much more frequently than the female respondents(35%) and their rate of 5,000-7,000 Won for a meal was most preferred as their average expenditure at one sitting in the restaurant. When eating Korean food at home or in a restaurant, the majority(5l,3%) of them think the soups(Tang) should be served coupled with their ordered meals. Among soups using flesh and meat as a staple material, they most preferred beef & bone soup(33.2%), followed by beep rib soup(30.4%) and beef soup with seasoned red pepper(l0.8%), and among soups using fish & shell and crustacean as a staple material, most preferred were hot fish soup(20.6%), loach soup(l5.2%) and hot crab soup(11.4%). Among soups using beans as a staple material, they most preferred soybean paste stew(33.2%), uncurdled soybean curd stew(29.4%) and Dambuk stew(l5.8%). Among soups using fowls and birds as a staple material, chicken soup with ginseng(51.9%), plain chicken soup(l8.4%) and chicken soup with red pepper sauce(l2.3%) falls on the most preferred. Among soups using vegetables and seaweeds as a staple material, most preferred are sea mustard soup(25.3%), Kimchi soup(16.8%), soybean paste soup with Chinese cabbage(13.0%) and bean sprout soup(10.1%). The soups(Tang) most preferred in the morning time are those soups whose staple materials are vegetables and seaweeds, such as sea mustard soup, bean sprout soup, Kimchi soup and soybean paste soup with Chinese cabbage while the soups most preferred for the lunch time are beef & bone soup, beep rib soup, chicken soup with ginseng and beef soup with seasoned red pepper while beef soup with seasoned red pepper, beef & bone soup, soybean curd stew and Kimchi soup are most preferred soups for the dinner time. The survey showed that 41 % of the subject preferred chicken soup with ginseng for a food considered good by themselves for their health. The male respondents preferred Bosin-tang(soup of edible-dog meat) than the female counterparts did, while the female respondents preferred chicken soup with ginseng than the male counterparts did. The survey showed that when eating korean traditional food, 70% of the subject are visiting a restaurant where soups are cooked delicious while 61% of the subject think that price does not matter if only food tastes good, which is reflecting that taste of food is a decisive factor in selecting menu rather than its price is. In conclusion, you can say that taste of soup is the most important factor creating steady customer in the restaurant, taking it into account Korean people most prefer their traditional food when dining out.

  • PDF

A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS (Titanium Implant의 Removal Torque에 관한 연구)

  • Lee, June-Seok;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

Effects of platelet-derived growth factor loaded bioresorbable membrane on periodontal regeneration (혈소판유래 성장인자 함유 흡수성 차폐막이 치주조직의 재생에 미치는 영향)

  • Ku, Young;Kim, Jeong-Eun;Han, Soo-Boo;Chung, Chong-Pyoung;Park, Yoon-Jeong;Lee, Seung-Jin;Kwon, Youg-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.61-78
    • /
    • 1997
  • PDGF-BB has been recognized as a highly potential growth factor for guided tissue regeneration in periodontal defect. This study carried out histologic and histometric evaluation of $200ng/cm^2$ PDGF-BB loaded bioresorbable membrane made from polyglycolic and polylactic acid. It was tested for its biocompatibility, ability to prevent epithelial downgrowth and amount of periodontal regeneration. Without membrane and PDGF-BB unloaded bioresorbable membrane were used as control. Healthy six beagle dogs were used. Each dog was anesthetized and buccal flaps were reflected in the mandibular and maxillary premolar areas. Buccal alveolar bone between the mesiobuccal and distobuccal line angles was surgically removed on the lower 2nd and 4th premolar in mandible, 2nd premolar in maxilla, to a level 4mm apical to the cementoenamel junction with creating a Class II buccal furcation defect for available space. Care was taken not to remove the root cementum layer and rubber impression materials were placed over each surgically created defect. Flaps were repositioned and sutured. Reconstructive surgery was performed 1 month after defect preparation. PDGF-BB loaded membranes and controls were randomly placed on maxillary 2nd premolars and mandibular 2nd and 4th premolars. Plaque control regimen was instituted with daily brushing with a 0.1% chlorhexidine digluconate during experimental periods. The animals were sacrificed 2 and 5 weeks after surgery and undecalcified specimens were prepared for histologic evaluation. The degree of coronal regrowth of new bone, new cementum and the amonut of new bone areas formed on the defected area of the PDGF-BB loaded membrnae turned superior to without membrane and drug unloaded membrane. Experimental membrane could prevent the epithelial downgrowth irrespective of drug loaded or not and showed good biocompatiblity, These results implicated that PDGF-BB loaded bioresorbable membrane could be highly useful tool for guided tissue regeneration of periodontal defects.

  • PDF

Study on Osseointegration of the Immediate Placement Using Korean Implant Systems in Beagle Dog (성견에서 즉시 임플란트 식립시 국내 임플란트에서의 골 유착반응에 관한 연구)

  • Seo, Jung-Yoon;Lee, Wook-Jae;Lee, Jong-cheol;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-Shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.223-236
    • /
    • 2007
  • This study was attempted to evaluate home-manufactured implants by placing $Stage-1^{(R)}$ Implant (Lifecore, Co., USA) whose surface is treated with REM that has already been varified clinically,$Chaorum^{(R)}$ Implant(Chaorum Co., Korea) whose surface treatment is same as that of Stage-1 Implant and $Atlas^{(R)}$ Implant(Cewellmedi Co., Korea) whose surface is treated with anodic oxidation immediately after the teeth of experimental animals were extracted to compare histological findings among them. Stage-l Implant(diameter: 3.5mm, length: IOmm), Chaorum Implant(diameter: 3.3mm, length: 8.5mm) and Cowell medi Implant(diameter: 4.0mm, length: 8.0mm) were placed into the mandible premolars of 2 adult beagle dogs immediately after their teeth were extracted, and then histological findings were analyzed at 6 weeks. After those implants were inserted directly after their teeth were extracted, the results of periotest were recorded, radiography was done, the subjects went through thorough control for 6 weeks, and then comparison among periotest, radiography and histological finding was made. After comparison of those findings, the values of periotest were satisfactory and bone healing was relatively satisfactory on radiography at 6 weeks. For osseointegration with the bone tissue, Stage-1 was 45.3%, Chaorum 55.3%, and Cowellmedi 52.5%, which was a satisfactory result. Although implant surgery immediately after teeth were extracted involves difficulties among recent implant surgeries, it is being frequently used in that it may reduce surgery hours, the frequency of surgery, and bone loss for patients. This experiment was conducted to evaluate the technological levels of home-manufactured implants that have been remarkably developed in recent years and in conclusion, those implants showed nearly similar result.

Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs (개에서 원형외고정장치를 이용한 관절주위 골절의 안정화)

  • Cheong, Hye-Yeon;Kim, Joo-Ho;Cha, Jae-Gwan;Seol, Jae-Won;Kim, Min-Su;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.523-526
    • /
    • 2014
  • Three dogs were admitted for repair of bone fracture. Case 1 (Maltese, 1.8 kg, intact female, 5-month-old) and case 2 (poodle, 3.0 kg, intact female, 6-month-old) had non-weight bearing lameness in the left pelvic limb, and case 3 (mixed, 3.3 kg, intact female, age unknown) had non-weight-bearing lameness in the left thoracic limb. On orthopedic examination, there was pain, crepitus, palpable instability and substantial soft tissue swelling on the affected side. No neurological deficits were identified. Radiographs revealed left proximal metaphyseal tibial and fibular fractures in cases 1 and 2, and left proximal metaphyseal radial and ulnar fractures in case 3. All cases had closed long-bone fractures with short juxta-articular fracture segments. Under fluoroscopic guidance, proper placement of the ring fixation elements was confirmed during surgery. Two or three rings were used to stabilize fractures with traditional circular external skeletal fixators (CESF). Postoperative radiographs showed acceptable alignment and apposition of the previously identified fracture. Time to radiographic union ranged from 5 to 14 weeks and there were no signs of implant failure or pin tract infection. Functional outcomes were excellent in all cases. CESF can be successfully used to reduce short juxta-articular fractures in which bone plates or external skeletal fixation cannot be applied.