• Title/Summary/Keyword: Division Device

Search Result 1,727, Processing Time 0.039 seconds

Adaptability test of the existing seeder in Foxtail millet & Sorghum (인력식 곡류 파종기를 활용한 조,수수 파종 적응성 구명)

  • Choi, Il-Su;Chung, Sun-Ok;Jun, Hyeon-Jong;Choi, Yong;Choi, Duck-Kyu;Kang, Tae-Gyoung;Hyun, Chang-Sik;Lee, Choung-Keun
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.259-264
    • /
    • 2014
  • This research was conducted to find design factors of seed metering device for developing seeder. It can be sowed precisely 1~3 seeds of Foxtail millet & Sorghum. To obtain fundamental information for designing seed metering device, we conducted adaptability test of the existing seeder in Foxtail millet & Sorghum. Major findings were as followings. Except of Model-A which was adapted sorghum(by seeding metering cup of width 3.9mm and length 4.5mm), seeders which were used in experiment showed that high value of miss-planted rates and more than four-planted rates. So to enhance precision of seeding in Foxtail millet & Sorghum, existing seeders were considered necessary by some supplementation.

Enhanced Photosensitivity in Monolayer MoS2 with PbS Quantum Dots

  • Cho, Sangeun;Jo, Yongcheol;Woo, Hyeonseok;Kim, Jongmin;Kwak, Jungwon;Kim, Hyungsang;Im, Hyunsik
    • Applied Science and Convergence Technology
    • /
    • v.26 no.3
    • /
    • pp.47-49
    • /
    • 2017
  • Photocurrent enhancement has been investigated in monolayer (1L) $MoS_2$ with PbS quantum dots (QDs). A metal-semiconductor-metal (Au-1L $MoS_2$-Au) junction device is fabricated using a standard photolithography method. Considerably improved photo-electrical properties are obtained by coating PbS QDs on the Au-1L $MoS_2$-Au device. Time dependent photoconductivity and current-voltage characteristics are investigated. For the QDs-coated $MoS_2$ device, it is observed that the photocurrent is considerably enhanced and the decay life time becomes longer. We propose that carriers in QDs are excited and transferred to the $MoS_2$ channel under light illumination, improving the photocurrent of the 1L $MoS_2$ channel. Our experimental findings suggest that two-dimensional layered semiconductor materials combined with QDs could be used as building blocks for highly-sensitive optoelectronic detectors including radiation sensors.

Design of A Force-Reflecting Device and Embedded Controller

  • Kim, Dae-Hyun;Moon, Cheol-Hong;Choi, Han-Soo;Kim, Yeong-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2397-2401
    • /
    • 2005
  • It is well understood that force reflecting coupled with visual display can be an important two-way communication channel in human-computer interaction. In this work, important components for a high-fidelity system bandwidth are force reflecting device and that all the computations including contact determination and response computation have to be performed in less than a millisecond. This paper describes a force-reflecting device and an embedded controller. The realized force-reflecting device is based on a novel serial type mechanical structure, and features compactness, high sustained output force capability, low friction, zero backlash, and enough workspace. The embedded controller reduces software computational load via main processor and simplifies hardware strictures by the time-division control. The device is integrated with existing dynamic simulation algorithms running separate workstation, so that objects can be manipulated in real time and the corresponding forces felt back by the operator.

  • PDF

Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

  • Kim, Tae Hoon;Shin, Yu Rim;Kim, Young Sam;Kim, Do Jung;Kim, Hyohyun;Shin, Hong Ju;Htut, Aung Thein;Park, Han Ki
    • Journal of Chest Surgery
    • /
    • v.48 no.6
    • /
    • pp.407-410
    • /
    • 2015
  • A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

Hybrid polymer-quantum dot based single active layer structured multi-functional device (Organic Bistable Device, LED and Photovoltaic Cell)

  • Son, Dong-Ick;Kwon, Byoung-Wook;Park, Dong-Hee;Kim, Tae-Whan;Choi, Won-Kook
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.97-97
    • /
    • 2010
  • We demonstrate the hybrid polymer-quantum dot based multi-functional device (Organic bistable devices, Light-emitting diode, and Photovoltaic cell) with a single active-layer structure consisting of CdSe/ZnS semiconductor quantum-dots (QDs) dispersed in a poly N-vinylcarbazole (PVK) and 1,3,5-tirs- (N-phenylbenzimidazol-2-yl) benzene (TPBi) fabricated on indium-tin-oxide (ITO)/glass substrate by using a simple spin coating technique. The multi-functionality of the device as Organic bistable device (OBD), Light Emitting Diode (LED), and Photovoltaic cell can be successfully achieved by adding an electron transport layer (ETL) TPBi to OBD for attaining the functions of LED and Photovoltaic cell in which the lowest unoccupied molecular orbital (LUMO) level of TPBi is positioned at the energy level between the conduction band of CdSe/ZnS and LiF/Al electrode (band-gap engineering). Through transmission electron microscopy (TEM) study, the active layer of the device has a p-i-n structure of a consolidated core-shell structure in which semiconductor QDs are uniformly and isotropically adsorbed on the surface of a p-type polymer core and the n-type small molecular organic materials surround the semiconductor QDs.

  • PDF

A simple technique for repositioning of the mandible by a surgical guide prepared using a three-dimensional model after segmental mandibulectomy

  • Funayama, Akinori;Kojima, Taku;Yoshizawa, Michiko;Mikami, Toshihiko;Kanemaru, Shohei;Niimi, Kanae;Oda, Yohei;Kato, Yusuke;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.16.1-16.6
    • /
    • 2017
  • Background: Mandibular reconstruction is performed after segmental mandibulectomy, and precise repositioning of the condylar head in the temporomandibular fossa is essential for maintaining preoperative occlusion. Methods: In cases without involvement of soft tissue around the mandibular bone, the autopolymer resin in a soft state is pressed against the lower border of the mandible and buccal and lingual sides of the 3D model on the excised side. After hardening, it is shaved with a carbide bar to make the proximal and distal parts parallel to the resected surface in order to determine the direction of mandibular resection. On the other hand, in cases that require resection of soft tissue around the mandible such as cases of a malignant tumor, right and left mandibular rami of the 3D model are connected with the autopolymer resin to keep the preoperative position between proximal and distal segments before surgical simulation. The device is made to fit the lower border of the anterior mandible and the posterior border of the mandibular ramus. The device has a U-shaped handle so that adaptation of the device will not interfere with the soft tissue to be removed and has holes to be fixed on the mandible with screws. Results: We successfully performed the planned accurate segmental mandibulectomy and the precise repositioning of the condylar head by the device. Conclusions: The present technique and device that we developed proved to be simple and useful for restoring the preoperative condylar head positioning in the temporomandibular fossa and the precise resection of the mandible.

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices : Bone Absorptiometric X-ray System (엑스선골밀도측정기의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Kim, Eun-Rim;Lee, Jun-ho;Lee, Chang-Hyung;Park, Chang Won
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.263-271
    • /
    • 2016
  • The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.

Catch and Bycatch of Dredge in the Yeongil Bay, Pohang (포항 영일만 형망어업의 어획 및 혼획 실태)

  • AN, Heui-Chun;PARK, Hae-Hoon;PARK, Jong-Myung;HONG, Sung-Eic;YOON, Byoung-Sun;PARK, Chang-Doo;BAE, Jae-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.4
    • /
    • pp.493-503
    • /
    • 2015
  • Species composition and bycatch rate of the catches by dredge with bycatch reduction device to reduce bycatch were estimated around Yeongil Bay, Korea at June, 2015. Total catches were collected 31 species as Chordata 10 species, mollusca 8 species, arthropoda 6 species, echinodermata 5 species, sipunculida 1 species, annelida 1 species during the experiment at the Yeongil Bay. The dominant species were Scapharca broughtonii, Callithaca adamsi, and Atrina pectinata and they reached 79.9% of the total catch. The catch rate of Scapharca broughtonii and Callithaca adamsi was 69.6% and 10.4% respectively. The rate of bycatch was 20.1%, consisted with Echinodemata 13.0%, Chordata 3.6%. The catch of ordinary dredge was 27 species 1,307 number 85,052g and that of dredge with escapement device was 21 species 1,690 number 91,648g. In conclusion, the dredge gear with bycatch reduction device has higher catch rate of target species and lower bycatch rate to non-target species than ordinary one.

The Impact of Intrapericardial versus Intrapleural HeartMate 3 Pump Placement on Clinical Outcomes

  • Salna, Michael;Ning, Yuming;Kurlansky, Paul;Yuzefpolskaya, Melana;Colombo, Paolo C.;Naka, Yoshifumi;Takeda, Koji
    • Journal of Chest Surgery
    • /
    • v.55 no.3
    • /
    • pp.197-205
    • /
    • 2022
  • Background: The integrated design of the HeartMate 3 (Abbott Laboratories, Chicago, IL, USA) affords flexibility to place the pump within the pericardium or thoracic cavity. We sought to determine whether the presence of a left ventricular assist device (LVAD) in either location has a meaningful impact on overall patient outcomes. Methods: A retrospective cohort study was conducted of all 165 patients who received a HeartMate 3 LVAD via a median sternotomy from November 2014 to August 2019 at our center. Based on operative reports and imaging, patients were divided into intrapleural (n=81) and intrapericardial (n=84) cohorts. The primary outcome of interest was in-hospital mortality, while secondary outcomes included postoperative complications, cumulative readmission incidence, and 3-year survival. Results: There were no significant between-group differences in baseline demographics, risk factors, or preoperative hemodynamics. The overall in-hospital mortality rate was 6%, with no significant difference between the cohorts (9% vs. 4%, p=0.20). There were no significant differences in the postoperative rates of right ventricular failure, kidney failure requiring hemodialysis, stroke, tracheostomy, or arrhythmias. Over 3 years, despite similar mortality rates, intrapleural patients had significantly more readmissions (n=180 vs. n=117, p<0.01) with the most common reason being infection (n=68/165), predominantly unrelated to the device. Intrapleural patients had significantly more infection-related readmissions, predominantly driven by non-ventricular assist device-related infections (p=0.02), with 41% of these due to respiratory infections compared with 28% of intrapericardial patients. Conclusion: Compared with intrapericardial placement, insertion of an intrapleural HM3 may be associated with a higher incidence of readmission, especially due to respiratory infection.