• 제목/요약/키워드: Diverter

검색결과 35건 처리시간 0.029초

회생에너지의 부스트인버터 구동방식을 적용한 서보시스템의 응답특성 향상 (Improving Quick Response of Servo System Using Boost-Diverter with Regenerating Energy)

  • 김태웅;최재호;민완기;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.339-341
    • /
    • 2006
  • The regenerating energy of the servo system is mostly consumed as heats through the regenerating resistors. For the response of the servo system to be more improved, the paper proposes the boost inverter using the regenerating energy, The proposed boost inverter has the additional capacitor installed on the DC-link circuit for charging the regenerating energy from the load. To get the better response of the servo system, the charged regenerating energy can be shortly re-applied to the output side as the finite impulse voltage, which can be controlled from information of reference voltages and feedbacked currents. It is verified by PSIM simulator that the response characteristics of the servo system using the proposed boost inventer is improved, comparing to that using the general inverter.

  • PDF

Circulation remodeling after flow diversion of an anterior communicating artery aneurysm: A case report

  • James Withers;Robert W. Regenhardt;Adam A. Dmytriw;Justin E. Vranic;Rudolph Marciano;James D. Rabinov
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제25권3호
    • /
    • pp.311-315
    • /
    • 2023
  • Anterior communicating artery aneurysms are the most common intracranial aneurysm and have a high risk of rupture which can lead to morbidity and mortality. Traditionally, intracranial aneurysms were treated by clipping with neurosurgical access. However, certain patients may prefer less invasive approaches or not represent open surgical candidates. Flow diverters, including flow-redirection endoluminal devices (FRED), are new-generation stents that are placed endovascularly by transfemoral or transradial access. Recent studies have demonstrated that FRED is both safe and effective, with complete occlusion of aneurysms in over 90% of patients. This case highlights an interesting phenomenon of post-flow diversion circulatory remodeling, where flow diverter treatment can alter the circle of Willis anatomy and physiology.

Retreatment of a recurrent giant aneurysm of the internal carotid artery after treatment with a flow-diverting stent

  • Ginam Kim;Junhyung Kim;Sang Kyu Park;Joonho Chung
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제25권2호
    • /
    • pp.208-213
    • /
    • 2023
  • Flow-diverting stents (FDSs) have proven advantageous for the treatment of large, fusiform, and dissecting aneurysms that are otherwise difficult to treat. Retreatment strategies for recurrent large or giant aneurysms after FDSs are limited to overlapping implantation of an additional FDS or definitive occlusion of the parent vessel. We report a recurrent giant aneurysm that was initially treated with an FDS with coils and was successfully treated with an additional FDS. Visual symptoms due to the mass effect of the recurrent aneurysm were completely resolved, and follow-up digital subtraction angiography revealed complete obliteration of the aneurysm. Additional FDS implantation for the retreatment of incompletely occluded aneurysms after the initial FDS treatment may be feasible and safe. Further studies are required to validate these results.

Flow diverter stenting for intracranial aneurysms in the pediatric population: Two case reports and literature review

  • Akram M Eraky;Christina Feller;Hatem Tolba;Mokshal Porwal;Raphael H. Sacho;Hirad Hedayat
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제26권1호
    • /
    • pp.58-64
    • /
    • 2024
  • The Pipeline Embolization Device (PED) is a flow-diverting intraluminal device that is approved for use in adults 18 years or older with internal carotid artery aneurysms. However, it can also be used off-label in pediatric patients with aneurysms that cannot be resolved with traditional endovascular treatments. Herein, we present two cases of flow diversion in the pediatric population with complete obliteration of the aneurysm and excellent outcomes. Flow diversion has been shown to be a safe endovascular option in treating complex aneurysms in children. Larger-sized, multicenter trials are encouraged to compare outcomes between flow diversion and other aneurysm treatment options given the rarity of pediatric aneurysms.

Flow Diverter Devices for the Treatment of Unruptured Vertebral Artery Dissecting Aneurysm

  • Kim, Chang Hyeun;Lee, Chi Hyung;Kim, Young Ha;Sung, Soon Ki;Son, Dong Wuk;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.891-900
    • /
    • 2021
  • Objective : Vertebral artery dissecting aneurysm (VADA) is a very rare subtype of intracranial aneurysms; when ruptured, it is associated with significantly high rates of morbidity and mortality. Despite several discussions and debates, the optimal treatment for VADA has not yet been established. In the last 10 years, flow diverter devices (FDD) have emerged as a challenging and new treatment method, and various clinical and radiological results have been reported about their safety and effectiveness. The aim of our study was to evaluate the clinical and radiological results with the use of FDD in the treatment of unruptured VADA. Methods : We retrospectively evaluated the data of all patients with unruptured VADA treated with FDD between January 2018 and February 2021 at our hybrid operating room. Nine patients with unruptured VADA, deemed hemodynamically unstable, were treated with FDD. Among other parameters, the technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcomes were evaluated. Results : Successful FDD deployment was achieved in all cases, and the immediate follow-up angiography showed intra-aneurysmal contrast stasis with parent artery preservation. A temporary episode of facial numbness and palsy was noted in one patient; however, the symptoms had completely disappeared when followed up at the outpatient clinic 2 weeks after the procedure. The 3-6 months follow-up angiography (n=9) demonstrated complete/near-complete obliteration of the aneurysm in seven patients, and partial obliteration and segmental occlusion in one patient each. In the patient who achieved only partial obliteration, there was a sac 13 mm in size, and there was no change in the 1-year follow-up angiography. In the patient with segmental occlusion, the cause could not be determined. The clinical outcome was modified Rankin Scale 0 in all patients. Conclusion : Our preliminary study using FDD to treat hemodynamically unstable unruptured VADA showed that FDD is safe and effective. Our study has limitations in that the number of cases is small, and it is not a prospective study. However, we believe that the study contributes to evidence regarding the safety and effectiveness of FDD in the treatment of unruptured VADA.

Nationwide Mortality Data after Flow-Diverting Stent Implantation in Korea

  • Kim, Tackeun;Kwon, O-Ki;Lee, Heeyoung;Cho, Min Jai;Jeong, Hyun Jean;Ban, Seung Pil
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.219-223
    • /
    • 2018
  • Objective : To investigate nationwide statistics on flow-diverting stent usage for cerebral aneurysm treatment and related mortality data. Methods : We requested data extraction from the National Health Insurance Service claims database using electronic data interchange codes (J3207064, J3207073). Patient and hospital information as well as death statistics were collected from the database. Results : A total of 169 procedures were performed using flow-diverting stents for cerebral aneurysm treatment from November 2014 to December 2016 in Korea. The majority of primary diagnosis was unruptured intracranial aneurysm. During the study period, nine subjects died, including one patient initially diagnosed with subarachnoid hemorrhage. The crude mortality rate was 5.3%. Five patients died within one month after the procedure; therefore, the estimated periprocedural mortality rate was $3.0{\pm}1.3%$. The mortality rate as of the last day of 2016 was $6.3{\pm}2.1%$. Conclusion : In a 171 person-year follow-up in a Korean series, nine deaths occurred after flow-diverting stent treatment. The crude mortality rate in Korea (5.3%) was higher than that reported in a previous meta-analysis (3.8%).

방전플라즈마소결법에 의한 W-Cu 연속경사기능재료의 제조와 특성에 관한 연구 (A Study on the Fabrication and Characteristics of Continuous W-Cu FGM by Spark Plasma Sintering)

  • 신철균;강태훈;권영순;김지순;김환태;석명진
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 춘계학술발표강연 및 논문개요집
    • /
    • pp.217-217
    • /
    • 2003
  • W-Cu 합금은 우수한 전기적, 열적 특성으로 인하여 열소산재료(Heat sink)로 많이 응용되고 있다. 첨단 전자부품 이외에도 핵융합로의 Diverter가 그 예로서, 내부는 고강도와 고융점의 특성을 요구하는 반면, 외부는 높은 열전도성을 필요로 한다. 그래서 동일한 조성의 일반적인 W-Cu 합금보다 W과 Cu의 조성이 점차적으로 변화하는 경사기능재료(Functionally Graded Materials)가 냉각효율이 클 것으로 기대된다. 현재, W-Cu FGM에 대한 많은 연구가 진행되고 있지만, 그 조성이 연속적으로 변화하는 W-Cu FGM에 대한 연구는 전무한 실정이다 본 연구에서는 방전플라즈마 소결장치(Spark Plasma Sintering System)와 용침고정을 이용하여 연속적인 조성변화를 갖는 W-Cu FGM을 제조하고 그 특성에 관해 분석하고자 하였다. 소결체가 밀도 변화를 갖게 되도록 제작한 특수 경사기능 몰드에 W분말을 장입한 후, 15㎬의 압력하에서 SPS를 이용하여 W소결체를 제조하였다. 제조된 W소결체는 수평관상로에서 수소분위기 하에 Cu 용침을 실시하여 W-Cu FGM을 제조하였다 SEM을 이용한 각 위치별 조직관찰과 Image Analyzer를 이용한 W과 Cu의 면적비, 그리고 비커스경도계에 의한 경도 측정을 실시하였다. 또 열기계적 분석기를 이용하여 측정된 선팽창률로부터 열팽창계수를 구하였다. 80$0^{\circ}C$에서 ?칭하는 반복적인 싸이클을 통해 열충격시험을 실시하였고, Laser flash method로 열확산계수를 측정하였다.

  • PDF

액체용 유량계교정시스템의 교정측정능력 평가 (CMC Evaluation of Flowmeter Calibration System for Liquid)

  • 이동근;김종섭;박태진;박종호
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.5-10
    • /
    • 2014
  • It is possible for the nation's largest flowmeter calibration system in K-water to calibrate flow rate up to $2,700m^3/h$ and diameter 800mm. However, the calibration and measurement capability of K-water's system is not satisfied in comparison with other developed countries. In this study, we find the dominant factors related to the uncertainty of weight and time measurement for gravimetric flowmeter calibration system. As a results of improving the system, the combined standard uncertainty has been improved $1.099{\times}10^{-3}$ to $2.332{\times}10^{-4}$. So calibration and measurement capability got 0.08 percent of the relative expanded uncertainty for maximum flow rate using the coverage factor(k=2).

Monte Carlo Simulation for Particle Behavior of Recycling Neutrals in a Tokamak Diverter Region

  • Kim, Deok-Kyu;Hong, Sang-Hee;Kihak Im
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.459-467
    • /
    • 1997
  • The steady-state behavior of recycling neutral atoms in a tokamak edge region has been analyzed through a two-dimensional Monte Carlo simulation. A particle tracking algorithm used in earlier research on the neutral particle transport is applied to this Monte Carlo simulation in order to perform more accurate calculations with the EDGETRAN code which was previously developed for a two-dimensional edge plasma transport in the authors' laboratory. The physical model of neutral recycling includes charge-exchange and ionization interactions between plasmas and neutral atoms. The reflection processes of incident particles on the device wall are described by empirical formulas. Calculations for density, energy, and velocity distributions of neutral deuterium-tritium atoms have been carried out for a medium-sized tokamak with a double-null configuration based on the KT-2 conceptual design. The input plasma parameters such as plasma density, ion and electron temperatures, and ion fluid velocity are provided from the EDGETRAN calculations. As a result of the present numerical analysis, it is noticed that a significant drop of the neutral atom density appears in the region of high plasma density and that the similar distribution of neutral energy to that of plasma ions is present as frequently reported in other studies. Relations between edge plasma conditions and the neutral recycling behavior are discussed from the numerical results obtained herein.

  • PDF

Healing of Aneurysm after Treatment Using Flow Diverter Stent : Histopathological Study in Experimental Canine Carotid Side Wall Aneurysm

  • Lee, Jong Young;Cho, Young Dae;Kang, Hyun-Seung;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권1호
    • /
    • pp.34-44
    • /
    • 2020
  • Objective : Despite widespread use of flow diverters (FDs) to treat aneurysms, the exact healing mechanism associated with FDs remains poorly understood. We aim to describe the healing process of aneurysms treated using FDs by demonstrating the histopathologic progression in a canine aneurysm model. Methods : Twenty-one side wall aneurysms were created in common carotid artery of eight dogs and treated with two different FDs. Angiographic follow-ups were done immediately after placement of the device, 4 weeks and 12 weeks. At last follow-up, the aneurysm and the device-implanted parent artery were harvested. Results : Histopathologic findings of aneurysms at 4 weeks follow-up showed intra-aneurysm thrombus formation in laminating fashion, and neointimal thickening at the mid-segment of aneurysm. However, there are inhomogenous findings in aneurysms treated with the same type of FD showing same angiographic outcomes. At 12 weeks, aneurysms of complete and near-complete occlusion revealed markedly shrunken aneurysm filled with organized connective tissues with thin neointima. Aneurysms of incomplete occlusion at 12 weeks showed small amount of organized thrombus around fringe neck and large empty space with thick neointmal formation. Neointimal thickness and diameter stenosis was not significantly different between the groups of FD specification and follow-up period. Conclusion : Intra-aneurysmal thrombus formation and organization seem to be an important factor for the complete occlusion of aneurysms treated using the FD. Neointimal formation could occur along the struts of the FD independently of intra-aneurysmal thrombus formation. However, neointimal formation could not solely lead to complete aneurysm healing.