• Title/Summary/Keyword: Diurnal

Search Result 804, Processing Time 0.031 seconds

A Study on Air Temperature-reducing Effects by Irrigation Reservoir (도시 내 소규모 관개저수지의 기온 저감효과에 관한 연구 - 수원시 일월저수지를 대상으로 -)

  • Zheng, Hai-Yan;Jin, Wen-Cheng;Lee, Kyoo-Seock;Oh, Sung-Nam
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.32-39
    • /
    • 2010
  • The air temperature-reducing effects by irrigation reservoir in urban area was investigated at Ilwol Pond (IWP). Air temperature and humidity data were observed at 10minute interval from September 1th, 2008 to August 31th, 2009. Air temperature of IWP and Sumsung Apartment (SAT) were analyzed to examine air temperature-reducing effects by IWP in terms of diurnal and seasonal variation. As a result, the average air temperature difference between IWP and SAT was $0.6^{\circ}C$ and the nighttime shows more air temperature-reducing effects. The dominant air temperature-reducing effects by IWP occurred at fall night and summer daytime. However, the air temperature-reducing effects by IWP is lower to that by Arboretum (ARB).

Changes in Atmospheric Mercury Concentrations in Seoul, Korea and its Significance: A Case Study Between 1997 and 2002

  • Kim Ki-Hyun;Kim Min-Young;Hong SM
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E1
    • /
    • pp.1-11
    • /
    • 2005
  • The concentration levels of gaseous elemental mercury (GEM) in ambient air have been investigated from a monitoring station located in Yang Jae district of Seoul, Korea for a long-term period covering 1997 through 2002. The mean concentration of Hg, if computed based on its hourly measurement data for this six-year period, was $5.32\pm3.53 ng m^{-3} (N = 27,170)$. The inspection of the diurnal distribution patterns indicated the presence of notably high concentration levels during nighttime relative to daytime (e.g., the mean hourly value as high as $9 ng m^{-3}$ in winter nighttime). When divided seasonally, the highest mean of $6.12 ng m^{-3}$ was also observed during winter followed by spring, fall, and summer. The results of our analysis confirmed the relative dominance of winter (seasonally) or nighttime (diurnally), while exhibiting a complicated trend on a long-term basis. Examination of our data over a different temporal scale consistently indicated that dynamic changes in Hg concentrations occurred through time in line with changes in the strength and diversity of the source processes. It is thus acknowledged that the presence of unusually high Hg levels is the consequence of intense man-made activities, while such signatures can vary in a competitive manner.

The Study on the High Nocturnal Concentration of Ground Level Ozone (야간 지표 고농도 오존에 관한 연구)

  • 김유근;홍정혜
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.545-554
    • /
    • 1998
  • The diurnal variation of O3 concentration shows two peaks, the first peak at noontime and the secondary peak at night. In order to show why the secondary peak, high nocturnal O3 concentration, occurs without sunlight which is a essential factor of a photochemical response, the O3 concentration, several weather elements and synoptic weather map were used for June∼September at 1995, 1996. The mean concentration of high nocturnal O3 concentration days is higher by 5.4 ppb than that of low nocturnal O3 concentration days. The nocturnal O3 concentration is higher than that of diurnal O3 concentration during high nocturnal O3 concentration days, at July, 1995 and June, 1996. The high nocturnal O3 concentration is related to low air pressure, high cloud cover and high wind speed. The correlation coefficient, r. between nocturnal O3 concentration and wind speed, pressure and cloud cover is 0.387, -0.218, and 0.194, respeftiviely. It is interesting that the O3 concentration increases at Pusan when the typhoon passes by. The same result showed at Taegu when the typhoon FAYE passed by. According to the analysis of nocturnal O3 concentration for June∼September at 1995 and 1996, it seems that the high nocturnal O3 concentration relates to the trough and cyclones passing by Pusan.

  • PDF

Comparison of the Characteristics of Precipitable Water Vapor Measured by Global Positioning System and Microwave Radiometer

  • Sohn, Dong-Hyo;Park, Kwan-Dong;Won, Ji-Hye;Cho, Jung-Ho;Roh, Kyoung-Min
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • In this study, global positioning system (GPS)-derived precipitable water vapor (PWV) and microwave radiometer (MWR)-measured integrated water vapor (IWV) were compared and their characteristics were analyzed. Comparing those two quantities for two years from August 2009, we found that GPS PWV estimates were larger than MWR IWV. The average difference over the entire test period was 1.1 mm and the standard deviation was 1.2 mm. When the discrepancies between GPS PWV and MWR IWV were analyzed depending on season, the average difference was 0.7 mm and 1.9 mm in the winter and summer months, respectively. Thus, the average difference was about 2.5 times larger in summer than that in winter. However, MWR IWV measurements in the winter months were over-estimated than those in the summer months as the water vapor content got larger. The results of the diurnal analysis showed that MWR IWV was underestimated in the daytime, showing a difference of 0.8 mm. In the early morning hours, MWR IWV has a tendency to be over-estimated, with a difference of 1.3 mm with respect to GPS PWV.

Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants (목본식물 형성층 전기저항에 영향을 주는 환경 요인)

  • Kim, Dong-Uk;Kim, Min-Soo;Lee, Bu-Yong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Diurnal Modification of a Red-Tide Causing Organism, Chattonella antiqua (Raphidophyceae) from Korea

  • Kim, So-Young;Seo, Kyung-Suk;Lee, Chang-Gyu;Lee, Yoon
    • ALGAE
    • /
    • v.22 no.2
    • /
    • pp.95-106
    • /
    • 2007
  • Blooms of Chattonella species are normally during summer in inland seas with high nutrients from the land and inflowing water. These blooms cause mass fish kills worldwide. We isolated a Chattonella strain from the south coast of Korea and identified it as C. antiqua. It is known that the morphological changes of phytoplankton correspond to the diurnal vertical migrations that follow an intrinsic biological clock and a nutrient acquisition mechanism during the day and night. In electron micrographs, C. antiqua clearly showed a radial distribution of lipid bodies in subcellular regions and plastids composed in which thylakoid layers were perpendicular to the surface. A single pyrenoid was present in each plastid and it was found at the end of the plastid towards the center of the cell. Throughout the day, plastids of C. antiqua cells appeared as an expanded net-like recticulum. During the night, however, the plastids changed their shape and contracted toward the cell periphery. The electron density of pyrenoids was increased in cells harvested during the night.

The Circadian Effects on Postural Stability in Young Adults

  • Son, Sung Min
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.142-144
    • /
    • 2017
  • Purpose: Few studies have addressed the effect of diurnal circadian rhythms on postural stability, and thus the aim of the present study was to examine circadian effects on static and dynamic postural stability in young adults. Methods: Twenty-four subjects (9 men, 11 women: age=$22.20{\pm}1.77$, height=$167.20{\pm}10.47$, weight=$59.85{\pm}10.66$) from a university community volunteered for this study. Static and dynamic balance testing, which recorded using a Good Balance system (Good Balance, Metitur Ltd, Finland) was conducted at 9:00, 13:00, and 17:00 hours on two consecutive days, and the sequencing of static and dynamic balance tests were randomized. Results were analyzed using the non-parametric one-way repeated Friedman test in SPSS version 18.0 (SPSS Inc., Chicago, IL, USA), and variable found to be significant were subjected to Wilcoxon post hoc testing. Results: Static and dynamic balance showed significant difference at the three times assessments (test at 9:00, 13:00, and 17:00) during circadian. In the post hoc test of static (anteroposterior distance, mediolateral distance and COP (center of pressure) velocity) and dynamic balance (performance time), 13:00 was the longer and faster than 9:00. Conclusion: These results indicated that control of postural balance is influenced by diurnal circadian rhythms, and confirm that control of postural balance is more effective and better performance in the 09:00 hours than 13:00 hours or 17:00 hours.

Metabolic Heat Production and Rectal Temperature of Newborn Calves

  • Mundia, C.M.;Yamamoto, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.304-307
    • /
    • 1997
  • Rectal temperature (Tr), skin surface temperatures (Ts), and heart rate (HR) were measured continuously from birth (day 1) till day 7, while resting heat production (HP) was measured in a chamber on days 1, 3, 5 and 7, in order to study the characteristic variation of Tr in newborn calves by heat balance methods. Despite constant levels of milk being given to the newborn calves each day, daily mean resting HP was lowest on the day of birth, then increased to peak on day 3 and then decreased slightly thereafter. Daily mean HR was higher on days 2, 3 and 4, than on other days. Tr exhibited diurnal rhythms and daily mean Tr was low on day 1, high on day 3, and then decreased slightly after day 3. Daily average mean skin temperature (mTs) was similar on all days. Mean body temperature (Tb) exhibited diurnal rhythms and had a similar range between days, suggesting that heat balance and thermoregulation were carried out effectively on each day. The variation of Tb appeared to be synchronized with that of HP and suggested that newborn calves might use variations in the levels of Tb to facilitate the body's required levels of heart loss.

Diurnal Size Distributions of Black Carbon by Comparison of Optical Particulate Measurements - Part I (광학 입자 측정기 비교 측정에 의한 입경별 일평균 블랙카본 분석 - Part I)

  • Park, Da-Jeong;Lee, Kwang-Yul;Park, Kihong;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Optical particle sizer (OPS), optical particle counter (OPC), and aethalomter were deployed to measure the particle number concentrations from 0.3 to $10.0{\mu}m$ and black carbon (BC) concentrations. Comparisons of particle number concentrations measured by OPS and OPC were conducted to evaluate the performance of the each optical instrument at the Gwangju sampling site ($35.23^{\circ}N$, $126.84^{\circ}E$) for 14 days from Dec. 27 in 2014. Although a good correlation ($r^2=0.99$) between the OPS and OPC was observed for both the particle number and volume concentrations, different relationships by BC concentrations can be associated with the intensities by different light scattering angles. In addition, based on diurnal patterns of size distributions in 24 hr running correlation coefficient determination, BC concentrations were highly related to the particles less than $0.3{\mu}m$ observed in the morning traffic hour.

EFFECT OF FEEDING PATTERN ON DIURNAL VARIATION IN FAECAL CHROMIC LEVEL WHEN USING CONTROLLED RELEASE DEVICES IN SHEEP

  • Lee, G.J.;Mortimer, S.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.1
    • /
    • pp.79-83
    • /
    • 1991
  • Diurnal variation in faecal chromic oxide levels was estimated from 4 hourly faecal sampling of 56 wethers allotted to one of six different feeding patterns. Sampling occurred on days 6 and 7 (Period 1) after a controlled release device was administered, and was repeated on days 14 and 15 (Period 2) following re-randomisation of the wethers to the feeding patterns. Increasing the frequency of feeding tended to be associated with higher faecal chromic oxide levels (p < 0.05), particularly in wethers fed thrice daily at 8 hour intervals. There was no interaction between feeding pattern and period, sampling day or time within-day. There were significant period x time within-day (p < 0.05) and day x time within-day (p < 0.001) interactions, indicating that variation in faecal chromic oxide between sample times was not consistent. This implies that sampling at any time of day is unlikely to result in a biased estimate of pasture intake, providing sufficient samples are collected. Significant period (p < 0.001) and period x day (p < 0.01) effects were associated with slow faecal chromic oxide equilibration in period 1. Equilibration did not occur until after day 7, indicating a need for caution when commencing sampling.