폐밀봉선원 처분시스템 예비 폐쇄후 안전성평가 (Preliminary Post-closure Safety Assessment of Disposal System for Disused Sealed Radioactive Source)

  • 이승희;김주열
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.33-48
    • /
    • 2017
  • An optimum disposal plan of disused sealed radioactive sources (DSRSs) should be established to ensure long-term disposal safety at the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju. In this study, an optimum disposal system was suggested and preliminary post-closure safety assessment was performed. The DSRSs disposal system was composed of a rock cavern and near surface disposal facilities at the Gyeongju LILW disposal facility. The assessment was conducted using GoldSim program, and probabilistic assessment and sensitivity analysis were implemented to evaluate the uncertainties in the input parameters of natural barriers. Deterministic and probabilistic calculations indicated that the maximum dose was below the regulatory limits ($0.1mSvyr^{-1}$ for the normal scenario, $1mSvyr^{-1}$ for the well scenario). It was concluded that the DSRSs disposal system would maintain environmental safety over a long-time. Moreover, the partition coefficient of Np in host rock, Darcy velocity in host rock, and density of the host rock were the most sensitive parameters in predicting exposure dose in the safety assessment.

Planning and decommissioning of a disused Theratron- 780 teletherapy machine and the dose assessment methodology for normal and radiological emergency conditions

  • Mohamed M.Elsayed Breky ;Muhammad S. Mansy;A.A. El-Sadek ;Yousif M. Mousa ;Yasser T. Mohamed
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.238-247
    • /
    • 2023
  • The present work represents a technical guideline for decommissioning a disused teletherapy machine model Theratron-780 and contains category one 60Co radioactive source. The first section predicts the dose rate from the source in case of normal and radiological emergency situations via FLUKA-MC simulation code. Moreover, the dose assessment for the occupational during the whole process is calculated and compared to the measured values. A suggested cordoned area for safety and security in a radiological emergency is simulated. The second section lists the whole process's technical procedures, including (preview, dismantle, securing, transport and storage) of the disused teletherapy machine. Results show that the maximum obtained accumulated dose for occupational were found to be 24.5 ± 4.9 μSv in the dismantle and securing process in addition to 3.5 ± 1.8 μSv during loading on the transport vehicle and unloading at the storage facility. It was found that the measured accumulated dose for workers is in good agreement with the estimated one by uncertainty not exceeding 5% in normal operating conditions.

국내 폐밀봉선원 분류체계 및 처분방식 연구 (Study of Classification and Disposal Method for Disused Sealed Radioactive Source in Korea)

  • 김석훈;김주열;이승희
    • 방사성폐기물학회지
    • /
    • 제14권3호
    • /
    • pp.253-266
    • /
    • 2016
  • 현행 규제요건에 따르면 국내에서 발생된 모든 폐밀봉선원은 자체처분 대상, 극저준위 또는 중 저준위 방사성폐기물에 해당하며, 기본적으로 방사능 농도를 기준으로 한 처분방식 제한규정을 준수해야 한다. 본 연구에서는 이러한 분류체계 이외에 IAEA 및 국외 폐밀봉선원 사용국의 방사성폐기물 분류체계, 폐밀봉선원 고유 특성 등에 대한 검토 및 분석결과를 토대로 반감기 및 A/D 값(각 선원의 방사능(A)을 작업자 및 일반 대중에 대한 잠재적 위험도를 의미하는 방사성핵종 고유의 'D값'을 활용하여 정규화한 수치로 선원의 상대적 위험을 평가하는 기초적인 기준으로 사용)에 대한 기준을 추가적으로 적용하여 국내 폐밀봉선원 분류체계에 대한 방안을 제시한 후, 각 범주에 대한 처분방식을 도출하였다. 다양한 처분시점을 상정한 국내 폐밀봉선원 특성 분석 및 처분방안별 대상 수량 체적 평가결과를 통해 본 연구에서 도출된 처분방안을 처분 예상시기와 무관하게 2015년 3월말 기준으로 임시저장 중인 모든 폐밀봉선원에 대해 적용할 수 있음을 확인하였다. 단, 방사능량을 확인할 수 없거나 비방사능 또는 A/D 값을 산출할 수 없는 선원에 대해서는 본 연구결과를 적용할 수 없으므로 처분방안 이행을 위해서는 사전에 비방사능, 체적 등의 선원 고유 특성이 반드시 확인되어야 한다.

폐밀봉선원 처분방식별 폐쇄후 예비안전성평가 (Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source)

  • 이승희;김주열;김석훈
    • 자원환경지질
    • /
    • 제49권4호
    • /
    • pp.301-314
    • /
    • 2016
  • 국내에서 발생한 폐밀봉선원은 현재 한국원자력환경공단 폐기시설에 임시 보관 중에 있으며 향후 중 저준위 방사성 폐기물 처분시설에 처분될 예정이다. 본 연구에서는 폐밀봉선원의 최적 처분방안 수립에 앞서 폐밀봉선원 처분시 폐쇄후 예비안전성평가를 수행하였다. 폐밀봉선원이 표층처분시설 또는 동굴처분시설에 처분되는 것으로 가정하였으며, GoldSim 전산코드를 사용하여 결정집단의 개인 피폭선량을 계산하였다. 평가결과 정상 시나리오시 최대 피폭선량은 두 가지 처분방식에 대해 약 $1{\times}10^{-7}mSv/yr$으로 나타났으며 이는 규제치인 0.1 mSv/yr에 대비하여 장기적으로 충분한 안전성을 확보할 수 있는 것으로 판단된다. 우물시나리오 시 최대 피폭선량은 표층처분시설에서 규제치인 1 mSv/yr를 초과하였으며 이는 $^{226}Ra$, $^{210}Pb$($^{226}Ra$의 딸핵종) 및 $^{237}Np$($^{241}Am$의 딸핵종)에 기인한 것으로 확인되었다. 동굴처분시설의 경우, 모든 핵종의 최대 피폭선량이 법적 규제치를 만족하나 $^{14}C$$^{237}Np$($^{241}Am$의 딸핵종)에 의한 피폭선량이 규제치 대비 10%를 초과하는 상대적으로 높은 값을 나타내는 것으로 확인되었다. 처분시설 폐쇄후 주민의 피폭선량은 반드시 법적 규제치 이하로 유지되어야 하므로 규제치를 초과 또는 이에 근접한 피폭선량을 유발하는 핵종인 $^{14}C$, $^{226}Ra$$^{241}Am$를 각 처분방식에서 제한할 필요가 있으며 안전한 영구 처분을 위한 처분전 관리가 요구된다.