• 제목/요약/키워드: Disturbance power supply

검색결과 58건 처리시간 0.024초

Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torches

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.591-598
    • /
    • 2011
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torches. A series resonant half-bridge topology is presented as a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. A plasma torch rated at 3MW, 2kA and having a physical size of 1m is selected to be the high enthalpy source for a waste disposal system. The steady-state and transient operations of a plasma torch are simulated. The parameters of a Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. The circuit simulation waveform shows that the ripple of the arc current can be maintained within ${\pm}10%$ of its rated value under the presence of a load disturbance. This power conversion configuration provides a high enough ignition voltage, around 5KA, during the ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

UPS를 내장한 컴퓨터용 SMPS (The SMPS with a Bulit-in UPS for Computer)

  • 이성룡;전칠환;이수원;고성훈;권혁대
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권8호
    • /
    • pp.495-499
    • /
    • 2004
  • UPS(Uninterruptible Power Supply) have been used to improve power source quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because batteries. So, a UPS size issue has received the attention in the power electronics industry. This paper proposed an implementation of the computer power supply with a bulit-in UPS controlled by the one-chip microprocessor to minimize UPS size. The experimental results verified the proposed SMPS with a bulit-in UPS for computer.

발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명 (Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site)

  • 김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

저압설비 플리커 특성평가를 위한 국내 저압계통 기준 임피던스 산정 연구 (A Study on the Calculation of Reference Impedances in Domestic Low-Voltage Power System)

  • 강문호;송양회;이흥호
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1651-1655
    • /
    • 2011
  • The reference impedances which is about 95% supply impedance value of residential consumers' supply impedances was published by IEC in 1980. The reference impedances are the standard values for use in determining the voltage disturbance characteristics of electrical equipment like the flicker. In IEC 60725, the reference impedances for premises having service current capacities less than 100A per phase and for service current capacities more than 100A per phase are recommended. And these reference impedances are targeted for the countries using 50Hz power frequency. Because of the frequency difference, the reactance values of the reference impedances will be increased in 60Hz power system like Korea, And also the reference impedances are different significantly each other according to declared voltage variation, power consumption and service wire length etc. Therefore It is needed to calculate the reference impedances suitable for domestic low-voltage power system. In this paper, the reference impedances for service current capacities less than 100A in 220/380V, 60Hz single-phase two wire and three-phase four wire low-voltage system are calculated, And the equations for service current capacities more than 100A to calculate the modulus value of maximum supply impedances are suggested base on IEC 60725 and the reference impedances for those are calculated on service current of 100A per phase.

Power Quality Warning of High-Speed Rail Based on Multi-Features Similarity

  • Bai, Jingjing;Gu, Wei;Yuan, Xiaodong;Li, Qun;Chen, Bing;Wang, Xuchong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.92-101
    • /
    • 2015
  • As one type of power quality (PQ) disturbance sources, high-speed rail (HSR) can have major impacts on the power supply grid. Providing timely and accurate warning information for PQ problems of HSR is important for the safe and stable operation of traction power supply systems and the power supply grid. This study proposes a novel warning approach to identify PQ problems and provide warning prompts based on the monitored data of HSR. To embody the displacement and status change of monitored data, multi-features of different sliding windows are computed. To reflect the relative importance degree of these features in the overall evaluation, an analytic hierarchy process (AHP) is used to analyse the weights of multi-features. Finally, a multi-features similarity algorithm is applied to analyse the difference between monitored data and the reference data of HSR, and PQ warning results based on dynamic thresholds can be analysed to quantify its severity. Cases studies demonstrate that the proposed approach is effective and feasible, and it has now been applied to an actual PQ monitoring platform.

주파수 변화율을 이용한 동적부하차단 방안 (A Scheme on the Dynamic Load Shedding Using Rate of Frequency Decline)

  • 이소영;장병태;이재욱;오화진;조범섭;김재현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.301-306
    • /
    • 2003
  • When a bulk power system experiences a serious disturbance or heavy load trip, the system frequency may drop and even collapse if the total generating power does not supply the system demand sufficiently. Since an isolated power system possesses a lower inertia and comes with limited reserves, the load shedding by under frequency relay becomes an important strategy to keep system natural frequency. This paper presents a scheme to determine the load shedding criteria by using the rate of change of frequency when the large disturbance happens.

주파수 변화율을 이용한 동적부하차단 계획 방안 (A scheme on the Dynamic Load Shedding Using Rate of Frequency Decline)

  • 이소영;장병태;김경호;추진부;유영식;조범섭;강계희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.289-291
    • /
    • 2002
  • When a bulk power system experiences a serious disturbance or heavy load trip, the system frequency may drop and even collapse if the total generating power does not supply the system demand sufficiently. Since an isolated power system possesses a lower inertia and comes with limited reserves, the load shedding by under frequency relay becomes an important strategy to keep system frequency. This paper presents a scheme to determine the load shedding criteria by using the rate of change of frequency when the large disturbance happens.

  • PDF

수밀댐퍼 구동장치의 강인제어에 관한 연구 (Design of a Robust Controller for a Watertight Damper Driving System)

  • 한승훈;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권2호
    • /
    • pp.45-51
    • /
    • 2017
  • Semi-submersible drilling rigs are offshore plants that perform functions such as ocean exploration for oil and gas acquisition, drilling and production, and storage and unloading of crude oil and gas. Semi-submersible drilling rigs use watertight dampers as emergency buoyancy holders. Since the watertight damper is an emergency shutoff device, it is mainly driven by a pneumatic driving system that can operate without a power supply. The pneumatic driving system has highly non-linear characteristics due to compressibility of air and external disturbance such as static and Coulomb friction. In this paper, a new control algorithm is proposed for a watertight damper driving system based on the sliding mode control with a disturbance observer. To evaluate control performance and robust stability of the designed controller, the control results were compared with the results obtained using the state feedback controller. As a result, it was confirmed that the pneumatic driving system for driving the watertight damper using the sliding mode controller with a disturbance observer can obtain excellent control performance against the parameter changes and the disturbance input.

다이나믹 UPS 시스템의 전력품질 외란발생을 위한 전압 Sag-Swell 발생기 (Voltage Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System)

  • 변우열;김중원;이기수;노의철;김인동;전태원;김흥근
    • 전력전자학회논문지
    • /
    • 제10권1호
    • /
    • pp.102-107
    • /
    • 2005
  • 본 논문에서는 새로운 방식의 전압 sag-swell 발생기를 제안하여 UPS(Uninterruptible Power Supply), DVR(Dynamic Voltage Restorer), DSTATCOM(Distribution Static Compensator), SSTS(Solid State Transfer Switch)등의 전력품질 개선장치들의 성능시험을 하는데 용이하도록 하였다. 제안한 방식에 대하여 단상과 3상의 경우 전압 sag, swell, outage, unbalance 발생원리 및 동작원리를 설명하였으며 시뮬레이션과 실험을 통하여 효용성을 입증하였다. 제안한 방식은 간단한 구조, 높은 신뢰도, 넓은 전압변동발생 범위, 간단한 제어 등의 장점 뿐 아니라 저렴한 비용으로 시스템을 구현할 수 있는 특징이 있으므로, 특히 실험실 레벨에서 효과적으로 경제적인 시스템을 구현하고자 하는 경우에 크게 기여할 것으로 기대한다.

전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성 (The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller)

  • 정연택;김원철;이사영;전지용;김현봉;이근홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF