• Title/Summary/Keyword: Disturbance detection

Search Result 159, Processing Time 0.023 seconds

A Study on the Collision Detection for Smart Door by Disturbance Observer (외란관측기를 이용한 스마트도어의 충돌감지에 관한 연구)

  • Park, Min-Kyu;Sung, Kum-Gil;Lee, Byungsoo
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.31-36
    • /
    • 2011
  • Smart Door(SD) is a human friendly power-assisted door system for passenger car doors. It offers comfort and safety to passengers and drivers by supplying additional power. In this study, dynamic system model and the equation of motion derivation are derived. And we propose the disturbance observer based collision detection algorithm for safety when opening the door. A disturbance caused by collision has a fast response compared to a friction, uncertainties and so on. The main idea this study is to estimate a variation of disturbance for stably and effectively detecting a collision. In order to evaluate a performance of collision detection, an experiment set up is constructed. The experimental results validate the usefulness of the proposed collision detection algorithm.

Development of Joint Controller and Collision Detection Methods for Series Elastic Manipulator of Relief Robot (구호로봇용 연성 매니퓰레이터를 위한 조인트 제어 및 충돌감지 알고리즘)

  • Jung, Byung-jin;Kim, Tae-Keun;Won, Geon;Kim, Dong Sup;Hwang, Junghun
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.3
    • /
    • pp.157-163
    • /
    • 2018
  • This paper deals with the development and application of control algorithms for series elastic relief robots for rescue operations in harsh environment like disasters or battlefield. The joint controller applied in this paper has a cascade structure combining inner loop for torque control and outer loop for position control. The torque loop contains feedforward and feedback controller and disturbance observer for independent, decentralized joint control. The effect of the elastic component and motor dynamics are treated as the nonlinear disturbance and compensated with the disturbance observer of torque controller. For the collision detection, Band Designed Disturbance Observer is configured to recognize/respond to external disturbance robustly in the continuously changing environment. The controller is applied to a 7-dof series elastic manipulator to evaluate the torque tracking and collision detection/response performance.

SIMULTANEOUS FAULT DETECTION AND CONTROL OF LINEAR TIME-INVARIANT SYSTEM VIA DISTURBANCE OBSERVER-BASED CONTROL APPROACH

  • PANG, GUOCHEN;JIAO, YU;ZHANG, HONGZI;CHEN, XIANGYONG;ZHANG, ANCAI;QIU, JIANLONG
    • Journal of applied mathematics & informatics
    • /
    • v.40 no.1_2
    • /
    • pp.47-59
    • /
    • 2022
  • This paper concerns the problem of simultaneous fault detection and disturbance reject control(SFDDRC) for a class of linear time-invariant system. In the framework of fault detection, residual generators are required to be robust to disturbances existing in the system. Different from most of the existing simultaneous fault and control(SFDC) methods, SFDDRC rejects the influences of disturbances on residual generators by disturbance observer-based control(DOBC). This not only effectively improves the accuracy of fault detection, but also solves the problem that most of the existing SFDC methods require that the disturbance must be bounded. Finally, a numerical example is given to verify the validity of the method.

Disturbance Observer Implementation and Speed Detection Improvement for Control Performance Enhancement of the Servo Motor (서보 모터의 제어성능 향상을 위한 외란 관측기 구현 및 속도검출방법 개선)

  • Park, Jung-Il
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.9
    • /
    • pp.36-46
    • /
    • 1994
  • A analog disturbance observer, which is suitable for servo motor drive, was employed to suppressi control of the impact drop disturbance. The main advantage of the observer is that a fast response disturbance estimation is obtained using the detected motor cuttent and speed. And the new M/T method for motor speed detection is proposed. The method should be able to reduce the detection dead time compared with the Ohmae's M/T method. Also, the low speed control of a servo motor using instantaneous speed detection method is described. To estimate the instantaneous speed from the average speed, the speed estimator of the first order is proposed. Actually we confirmed that these methods improve the speed control performance of the servo system with experiments.

  • PDF

A Voltage Disturbance Detection Method for Computer Application Loads (컴퓨터 응용 부하들을 위한 전압 외란 검출 방법)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.245-248
    • /
    • 2000
  • In this paper a novel method for voltage disturbance detection is presented. This is a instantaneous detection method using normalized error get in synchronous reference frame and also it is implemented in digital. Feedback noise the problem of digital implementation is removed by a digital filter of which the time delay is compensated through numerical analysis.

  • PDF

Power Plant Fault Monitoring and Diagnosis based on Disturbance Interrelation Analysis Graph (교란들의 인과관계구현 데이터구조에 기초한 발전소의 고장감시 및 고장진단에 관한 연구)

  • Lee, Seung-Cheol;Lee, Sun-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.9
    • /
    • pp.413-422
    • /
    • 2002
  • In a power plant, disturbance detection and diagnosis are massive and complex problems. Once a disturbance occurs, it can be either persistent, self cleared, cleared by the automatic controllers or propagated into another disturbance until it subsides in a new equilibrium or a stable state. In addition to the Physical complexity of the power plant structure itself, these dynamic behaviors of the disturbances further complicate the fault monitoring and diagnosis tasks. A data structure called a disturbance interrelation analysis graph(DIAG) is proposed in this paper, trying to capture, organize and better utilize the vast and interrelated knowledge required for power plant disturbance detection and diagnosis. The DIAG is a multi-layer directed AND/OR graph composed of 4 layers. Each layer includes vertices that represent components, disturbances, conditions and sensors respectively With the implementation of the DIAG, disturbances and their relationships can be conveniently represented and traced with modularized operations. All the cascaded disturbances following an initial triggering disturbance can be diagnosed in the context of that initial disturbance instead of diagnosing each of them as an individual disturbance. DIAG is applied to a typical cooling water system of a thermal power plant and its effectiveness is also demonstrated.

Real-Time Detection of Seismic Ionospheric Disturbance Using Global Navigation Satellite System Signal (위성항법 신호를 이용한 지진에 의한 전리층 교란 실시간 검출 기법 연구)

  • Song, Junesol;Kang, Seon-Ho;Han, Deok-Hwa;Kim, Bu-Gyeom;Kee, Changdon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.8
    • /
    • pp.549-557
    • /
    • 2019
  • In this paper, we focus on the real-time detection method of a seismic ionospheric disturbance using Global Navigation Satellite System (GNSS) signal. First, the monitor for the detection of the seismic ionospheric disturbance is studied based on the estimated ionospheric delay using the GNSS signals. And then, the threshold for the automatic detection is computed. Moreover, to discriminate the seismic ionospheric disturbance against the other ionospheric anomalies due to other error sources such as cycle slips, the signatures of the ionospheric perturbation caused by the seismic wave is investigated. Based on the observation, the detection strategy is proposed. Using GPS observations collected from the 47 permanent stations in South Korea and Japan, the proposed real-time detection method is evaluated.

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.

Automatic Moving Target Detection, Acquisition and Tracking using Disturbance Map in Complex Image Sequences (복잡한 영상신호에서 디스터번스 맵을 이용한 움직이는 물체 자동감지, 획득 및 추적)

  • Cho, Jae-Soo;Chu, Gil-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.199-202
    • /
    • 2003
  • An effective method is proposed for detecting, acquisition and tracking of a moving object using a disturbance map method in complex image sequences. A significant moving object is detected and tracked within the field of view by computing a modified disturbance map method between an Input image and a temporal average image. This method is very efficient in the serveillance application of digital CCTV and an automatic tracking camera. Experimental results using a real image sequence confirmed that the proposed method can effectively detect and track a significant moving object in complex image sequences.

  • PDF

A Realization of Reduced-Order Detection Filters

  • Kim, Yong-Min;Park, Jae-Hong
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.1
    • /
    • pp.142-148
    • /
    • 2008
  • In this paper, we deal with the problem of reducing the order of the detection filter for the linear time-invariant system. Even if the detection filter is generally designed in the form of full order linear observer, we show that it is possible to reduce its order when the response of fault signals is limited to a subspace of the estimation state space. We propose a method to extract the subspace using the observer canonical form considering the dynamics related to the remaining subspace acts as a disturbance. We designed a reduced order detection filter to reject the disturbance as well as to guarantee fault detection and isolation. A simulation result for a 5th order system is presented as an illustrative example of the proposed design method.