• Title/Summary/Keyword: District Heating system

검색결과 235건 처리시간 0.068초

지역난방 태양열시스템 해석 프로그램 개발 (The Development of Analysis Program of Solar Heating System for District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.190-195
    • /
    • 2008
  • This study aims to develop the thermal performance and economic analysis program of solar heating system applied to district heating systems. The program, named SOLAN-DHS, is consisted of four modules like as user's interface for system input/output, library, and utilities and a calculating engine. SOLAN-DHS simplifies user's input data through the database and can design 5 different types of solar systems. Due to the user-friendly layout, all design parameters can be changed quickly and easily for the influence on system efficiency. The reliability of SOLAN-DHS was finally verified by the experiments.

  • PDF

지역난방 공동주택에 설치하는 급탕 2단 열교환기의 용량 적정성 평가에 관한 연구 (Design Capacity Evaluation of 2-stage Hot Water Heat Exchanger in Apartment Mechanical Rooms with District Heating System)

  • 정광섭;사기용;김래현;이훈
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.456-461
    • /
    • 2009
  • Recently, an increasing interest in district heating system has emerged rapidly, In this paper, the physical measurements and data to be monitoring through the internet were carried out with regard to hot water heating energy consumption at the three apartment housings with district heating system in Sang-am district of Seoul, Korea, Measurements were made of the thermal factors such as the pressure of heating pipe, flow rates, hot water temperature and etc, The objective of this study is to compare the design capacity of reheat exchanger with that of preheat exchanger in order to evaluate for the number of plates of two exchangers to be distributed properly.

공동주택의 에너지소비량 및 난방운전 실태에 관한 조사연구 (An investigation on the heating energy consumption and operating condition in apartment houses)

  • 신용태
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 1994년도 학술발표대회논문집 상
    • /
    • pp.45-50
    • /
    • 1994
  • The energy consumption in apartment houses is investigated according to the heating systems, that is, district, central, and individual heating systems. And, operating conditions of intermittent heating are surveryed and analysed in the central heating systems. As a result, each annual energy consumption of district, central and individual heating system is 143.56 Mcal/m2year, 216.78 Mcal/m2year and 150.68 Mcal/m2year, Also, the heating is generlly started at 04:00 and 17:00 of each day, and the heating system is operated for 2~3 hours per each time.

  • PDF

지역난방 수용가측 효율관리를 위한 IoT 기반 시스템 구축에 관한 연구 (A Study on the Construction of IoT based System for District Heating Customer-side Energy Efficiency Management)

  • 윤정미;이상학;안창구;엄재식
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.113-122
    • /
    • 2017
  • 우리나라 집단에너지 사업의 주요축인 지역난방 시스템은 경제성 있는 열에너지 공급시스템으로 국민편익과 안전에 많은 기여를 해 왔다. 하지만 관리주체의 불명확함, 전문기술인력 부족 등으로 인해 공동주택 수용가측의 열효율저하, 요금 불공정등의 문제가 발생하고 있다. 본 논문에서는 관리사각지대인 지역난방 수용가측 설비의 효율 및 고장관리를 위해 필요한 모니터링 포인트를 제안하고, 이를 표준화 하기 위한 표준참조모델을 제안한다. 또한 IoT 센서 기술을 적용하여 실시간 모니터링 및 통합관리 시스템을 구축함으로써, 지역난방 수용가시설에 대한 서비스 질 개선과 에너지 효율향상을 위한 기술적 방법론을 제안한다.

지역난방 아파트의 난방 관리 실태에 관한 연구 (A Study on the Residential Energy Management of Apartment in the District Heating Area)

  • 최남숙
    • 가정과삶의질연구
    • /
    • 제7권1호
    • /
    • pp.79-95
    • /
    • 1989
  • Household energy consumption had influenced on the ecological system's environment. Household's exceeding energy consumption requires the development of resources and the risk. Thus this study attempted to find the household heating management, The purpose of this study was to investigate the household's heating management in the area of district heating. The major finding were; 1) The district heating was accepted positively and the benefit of this system was utilized very well in the household. 2) Variances in heating energy consumption was explained by the family size at October, residential period at October and November and the temperature of living room at October, November and December. 3) Compaired to central heating apartment, the low heating expenditure was characterize in the household of 4-5 persons, nuclear family at October, moderated heating control, using extra heating facilities at November. An in the December, that household was that husband has graduated college, temperature of the living room was some cold, and house wives was the full-time homemaker.

  • PDF

지열을 이용한 매음리 지역난방에 관한 에너지 및 엑서지 분석 (Energy and Exergy Analysis of Maeeum-Ri Geothermal District Heating System)

  • 김진상
    • 한국지열·수열에너지학회논문집
    • /
    • 제5권2호
    • /
    • pp.13-19
    • /
    • 2009
  • This study describes energy and exergy analysis of the Maeeum-Ri Geothermal District Heating System(MGDHS) of Ganghwa Island, Incheon, Korea. Design data are used to assess the performance of the geothermal district heating system. Geothermal resources of MGDHS are found to be low quality with specific exergy index of 0.029. Exergy losses occur in the pumps and heat exchangers as well as in the geothermal Quid and direct discharge. As a result, the total exergy losses accounts for 5.2% in pumps, 47% in the discharge, and 3.3% in heat exchanger based on the total exergy input to the entire MGDHS. The overall energy and exergy efficiencies of the system are found to be 28.8% and 44.5%, respectively.

  • PDF

지역난방 사용자기계실 내 열수송관 차압을 이용한 발전 및 제어 기술 (Power Generation and Control System Using Differential Pressure of District Heating Pipeline in a Substation)

  • 김경민;박성용;오문세
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.90-96
    • /
    • 2017
  • 지역난방 열수송관을 통해 중온수를 공급할 때 고압의 중온수로부터 열사용자 설비(지역난방 열교환기)를 보호하고 온도조절을 원활히 하고 유체의 원거리 공급을 위해 차압유량조절밸브를 통해 압력을 조절하거나 압력을 감소시키고 있다. 하지만, 고압 유체 사용에 따라 압력조절밸브에서 캐비테이션이 발생하여 잦은 고장 및 오작동을 유발하여 많은 문제가 발생하고 있으며, 사업자 및 사용자 모두에게 에너지 손실 및 민원 유발 등의 원인이 되고 있다. 이러한 문제를 해결하기 위해 연구 중인 1차측 차압유량조절밸브를 수력터빈으로 대체하여 차압에너지를 전기에너지로 변환하고, 전기를 2차측 펌프의 동력으로 활용하는 에너지 절감기술을 소개하고자 한다.

지역난방 시스템의 순환수에 따른 보일러 튜브의 부식 특성 (Corrosion Behavior of Boiler Tube under Circulation Water Conditions in District Heating System)

  • 홍민기;조정민;송민지;김우철;하태백;이수열
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.287-291
    • /
    • 2018
  • In this study, corrosion behavior of a SA178-A alloy used in the boiler tube of a district heating system was investigated in different environments where it was exposed to pure water, district heating (DH) water, and filtered district heating (FDH) water. After the corrosion test, the surface morphology was examined for observation of the number of pitting sites and pitting area fraction, using a scanning electron microscope. The DH water and FDH water conditions resulted in a lower corrosion potential and pitting potential, and revealed a significantly higher corrosion rate than the pure water condition. The pitting sites in the DH water (pH 9.6) were approximately eighteen times larger than those in the pure water (pH 9.6). Compared to the DH water, the corrosion potential became more noble in the FDH water condition, where iron ions were reduced through filtration. However, the corrosion rate increased in the FDH water due to an increased concentration of chloride ions, which deteriorated the stability of passive film.

난류발생기를 가지는 원형 파이프내에서의 마찰저감 및 열전달율에 관한 실험적 연구 (Experimental Study on the Drag Reduction & Heat Transfer Ratio in the Circular Pipe with Swirl Generater)

  • 김성수;조성환;윤석만
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.430-435
    • /
    • 2008
  • Total lengths of domestic pipe network for district heating system are above about 2,500Km. A lots of pumping power for heat transportation through long pipe are required by the flow friction of pipe surface. Until now there have been considered about various methods to reduce the flow friction for district heating system such as using surfactants and turbulence promoters by swirl flow and baffles etc. At this study, swirl flow generator was tested about the possibility to increase the heat transfer ratio at the heat exchanger in the case which the suppling water temperature increased from $50^{\circ}C$ until $120^{\circ}C$. Experimental results showed that the heat transfer ratio increased and also pressure increase ratio increased simultaneously in the case which swirl flow generator installed. The amount of the increasing ratio for heat transfer and pressure were reached until 4.33% and 11% at the case of $120^{\circ}C$ suppling temperature which domestic district heating system were using.

  • PDF