• Title/Summary/Keyword: District Heating system

Search Result 235, Processing Time 0.04 seconds

The Study on Program for Happy House Sanjeon District Center in Jung-gu, Ulsan City (해피하우스지역센터 프로그램에 관한 연구)

  • Kim, Sun-Joong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.161-166
    • /
    • 2011
  • This research was conducted in order to suggestion management program of Happy house center which facility of detached housings, multi family housing, and semi-detached housing management. This study's purpose is to systematically help create a district customized co-management housing management system among detached housing area by reflecting resident opinion and simultaneously provide basic research. The area of research is Sanjoen district in Ulsan city that compact old detached houses. The research study's results are follows: First, the overall survey results showed that most respondents demanded program of happy house center for housing energy deduction method and support of house insulation cost and heating fuel cost. Second, happy house center try to order of priority or housing maintenance and seek of cost deduction plan. Third, happy house center propose the Maeulmandeulgi(Machizkuri) program or housing management plan for residents' talent contribution.

  • PDF

Evaluation of the Heating and Cooling Systems in School Buildings (학교건물 냉난방설비시스템의 실태조사)

  • AHN, Chul-Lin;KIM, Dong-Gyue;KUM, Jong-Soo;PARK, Jong-Un;PARK, Hee-Ouk;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.1
    • /
    • pp.18-25
    • /
    • 2005
  • We have researched 10,811 schools to evaluate the characteristics of school buildings and the conditions of heating and cooling systems at the elementary, middle and high school levels. Air conditioning systems in school buildings are related to school scale, and 35% of the researched schools have less than 10 air conditioned classrooms among all of the schools in Korea. The LOADSYS is used to grasp the characteristics of school buildings heating and cooling load. From the results of this work, the heating load differs by nearly 24% between Seoul and Busan, but other than that there are not so many serious regional differences. Almost 85.4% of the classrooms are equipped with heating facilities and 6.9% of them are equipped with heating and cooling facilities. As a result, it is necessary to make improvements in 31.8% of the classrooms using only heaters and 14.6% of the classrooms not equipped with HVAC. The survey shows that there is a wide gap in the heating equipment status of the classrooms according to the region and school district.

Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control (유량제어방식에 따른 태양열 급탕시스템의 열성능 평가)

  • Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.

A Case Study for the Economic Feasibility Model and Analysis of a GDHS Given Geothermal Temperature (기대지열온도하에서 GDHS의 경제성분석 사례연구)

  • Yang, Moon-Hee;Kim, Tai-Yoo;Lee, Sang-Kyu
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.1
    • /
    • pp.115-127
    • /
    • 1997
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. The advantages of GDHS include saving fuel consumption as well as reducing air pollution. This paper presents a case study for the economic feasibility model and analysis of a GDHS with which central/individual heating systems are replaced. Configuring to a simplified GDHS which consisits of subsurface systems, surface systems, and transmission/distribution systems, we find out the properties of the system and the model parameters affecting the initial investment/operating costs in order to develop a classical economic feasibility model given geothermal temperature. Based on our model parameter space, we analyzed the geothermal development project of the Jejoo Island probabilistically given prior information such as the expected geothermal power, the demand size and the length of transmission/distribution pipes.

  • PDF

A Scheme for Standardization of the Apartment Management Expenses Levy in the District of Busan(I)-Focused on the Apartments of the Individual Heating System- (부산지역 공동주택 관리비 부과내역서 표준화(I) - 개별난방방식 아파트를 중심으로 -)

  • 강혜경
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.1
    • /
    • pp.113-136
    • /
    • 2001
  • The purpose of this study was to develop a scheme for standardization of the apartment management expenses levy focused on the apartments of the individual heating system in Busan. The researcher with apartment managers and executive secretaries of Busan Citizen's Coalition for Economic Justice performed a scheme for standardization through discussion of 20 times as well as investigation of theoretical literature. This scheme for standardization was based on the Act for Community of Dwelling Houses. It is

    to show the scheme for standardization of apartment management expenses levy all-inclusive.

  • PDF
  • A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems (지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구)

    • Kang, Hee Jeong;Lee, Hyun Su;Jang, Myung Hun
      • Journal of the Korean Society for Geothermal and Hydrothermal Energy
      • /
      • v.14 no.1
      • /
      • pp.1-7
      • /
      • 2018
    • A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.

    Compact module and control system for district heating system (지역난방용 콤팩트 유닛 및 제어기 개발)

    • Lee, Young-Soo;Baik, Young-Jin;Jung, Dae-Hun;Kim, Jin;Um, Chul-Jun
      • Proceedings of the SAREK Conference
      • /
      • 2009.06a
      • /
      • pp.1343-1347
      • /
      • 2009
    • In order to comply with the global energy crisis and environment problem, it is necessary to research and develop the energy utilization technology with the reduction of the primary energy usage. Although the increasing rate of energy consumption started to attenuate, the entire consumption of energy as well as $CO_2$ emission rate tends to increase steadily along with an economic growth in Korea. The energy demand in Korea increases by annual 3.7% during the period from 2000 to 2006. And it is expected that we should take a charge of the greenhouse gas reduction obligation by the Climatic Change Convention(Kyoto Protocol) during the 2nd pledge period($2013{\sim}2017$). According to the IEA report in 2005, the emission amount of carbon dioxide is the 10th place in the world, and the increasing rate is 4.7% annually. Considering the economic scale of Korea, the degradation of energy usage is inevitable when the greenhouse gas reduction obligation come into effect. Therefore, effective energy usage is a very important issue to minimize baneful influence on industrial and economic activities.

    • PDF

    A Study on the Integrated Fusion Technology Between a Carbon Dioxide Emission and a District Cooling Energy Using a Cold Energy ($CO_2$ 배출문제와 냉열이용 지역집단 냉방에너지에 관한 통합적 융합기술 연구)

    • Kim, Chung-Kyun
      • Journal of the Korean Institute of Gas
      • /
      • v.10 no.4 s.33
      • /
      • pp.34-40
      • /
      • 2006
    • This paper provides a fusion technology between a district cooling energy system and an environment conservation policy based on the energy savings and reusable cold energy resources. The district heating and cooling systems are very effective ways for an energy saving, a cost reduction and a safety control. It is necessary to equalize the energy savings and an environmental preservation policy for an improved human lift. A gasification process of a liquefied natural gas, cooling water from deep seawater and an ice water thermal storage system may produce a cold energy. A district cooling system is used to cool an apartment, office buildings and factory facilities with a cooling energy supply pipeline. LNG cooling energy will switch a conventional air-conditioning system, which is operated by on electrical energy and a Freon refrigerant. Coincident with significant clean energy and operating cost savings, LNG cold energy system owen radical reductions in an air-borne pollutant, $CO_2$ and the release of environmentally harmful refrigerants compared with that of the conventional air-conditioning system. This study provides useful information on the fusion technology of a LNG cold energy usage and energy savings, and environmental conservation.

    • PDF

    Characteristics of the Ice Slurry Transportation System for District Cooling Depending on the Transportation Lines (지역냉방용 아이스슬러리 수송시스템의 배관방식에 따른 특성)

    • Lee Yoon-Pyo;Chung Jae-Dong;Yoon Seok-Mann
      • Korean Journal of Air-Conditioning and Refrigeration Engineering
      • /
      • v.18 no.7
      • /
      • pp.571-577
      • /
      • 2006
    • The characteristics of ice packing factor (IPF) at the ice slurry system using one line type are compared with the system using two lines type. The installation space for one transporting line is saved at the one line system. For the one line type, the ice packing factor is reduced along the downstream, but for the two lines type, the ice packing factor is fixed. For the one line system, mass flow rate in the main line is fixed along the down-stream, but for two lines system, the mass flow rate in the main line is reduced along the downstream. For one line system, along the down stream after IPF=0, the temperature at the main steam is increased, and the extracted mass flow is increased. The initial IPF, at which the IPF is not arrived at zero upto the final node, is proposed for the B area.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.