• 제목/요약/키워드: District Heat

검색결과 238건 처리시간 0.027초

생활(生活)쓰레기 소각열(燒却熱) 이용실태(利用實態)에 관(關)한 연구(硏究) - 대구광역시(大邱廣域市)를 중심(中心)으로 - (A Study on Using Incineration Heat of Municipal Solid Wastes - Case Study of Taegu metropolitan city -)

  • 홍원화;이강국;이지희
    • KIEAE Journal
    • /
    • 제1권1호
    • /
    • pp.45-52
    • /
    • 2001
  • This study aims to make a fundamental data for a policy-making decision in treatment and disposal of municipal solid wastes and presents a research data on the discharge properties of municipal solid wastes and making a unit of them in the Taegu metropolitan city. The results can be summarized as follows; survey the discharge properties of municipal solid wastes, calorific values and to present a research-data in supplying incineration-heat of wastes with the area of Sung-seo in Taegu. So, using fundamental data for planning and running wastes-incineration plants as well as trying to make better Urban Environmental Infra-structure. The results are obtained from the study. 1) The proportion of combustible wastes in Taegu increased from 89.6% to 94.47% during 1993~2000. However, the proportion of incombustibles decreased from 10.4% to 5.53% during 1993~2000. 2) The value of representative properties is about 1500~2000kcal/kg. So we can expect that it should be made use of energy-resources positively. 3) The heat from Sung-seo wastes-incineration plants is used to produce electronic-energy for wastes-incineration plants in summer season. The heat from Sung-sea wastes-incineration plants is in charge of 27% which of supplying the area of Sung-seo with district heating energy in winter season.

  • PDF

위성영상의 시계열 분석을 통한 미기후변화 분석 -대구시 달서구를 대상으로- (A Study on Microclimate Change Via Time Series Analysis of Satellite Images -Centered on Dalseo District, Daegu City-)

  • 백상훈;정응호
    • 한국지리정보학회지
    • /
    • 제12권2호
    • /
    • pp.34-43
    • /
    • 2009
  • 바람길 도입을 통한 도시열섬현상의 저감 방안에 관한 선행연구들을 바탕으로 본 연구에서는 도시화과정을 거치면서 발생하는 토지피복의 변화가 도시공간의 찬공기 생성 및 유동에 어떠한 변화를 일으키는지 분석하였다. 연구 대상지로는 우리나라의 대표적인 극서(劇暑)도시이며 1980년대 이후 주변 지역을 편입하여 도시가 확장된 대구시 내에서도 특히 지표온도의 변화가 크고 1988년 신설되어 급격한 인구 증가가 이루어졌던 달서구를 대상으로 연구를 실시하였다. 시간적 범위로는 1987년, 1997년, 2007년의 여름철 위성영상을 이용하여 20년간의 도시미기후 변화를 연구하였다. 연구결과 자연 토지피복의 감소와 인공 토지피복의 증가는 찬공기 생성 및 유동에 불리하여 도심지에서의 찬공기의 양과 높이가 현저히 낮아졌다. 이는 찬공기 생성 및 유동기능이 토지피복에 의해 영향을 받는 것으로 보였다. 지속적인 찬공기 생성 및 유동의 확보를 위해서는 도시를 둘러싼 주변지역의 공간적 특성을 분석하여 도시개발이나 도시재생을 실시해야 하며, 이를 통해 쾌적하고 건강한 도시조성이 될 수 있을 것으로 사료된다.

  • PDF

구역전기 사업시 CHP와 신재생에너지 하이브리드 시스템의 최적공정 모델 (Optimization Process Models of CHP and Renewable Energy Hybrid Systems in CES)

  • 이승준;김래현
    • 에너지공학
    • /
    • 제26권2호
    • /
    • pp.99-120
    • /
    • 2017
  • 한국지역난방공사 SS지사에서는 시설용량 전기 99MW, 열 98Gcal/h 규모의 열병합(Combined Heat & Power) 발전소를 구역전기사업으로 운영하고 있다. 이 지역은 경기불황과 수요감소로 하절기 6~9월 사이에 잉여열 처리문제가 발생하여 발전기를 가동하기 곤란한 상황이므로 경제성 있는 에너지 신사업모델 개발이 절실하다. 본 연구에서는 이곳의 실제 운영자료를 기반으로 신재생 에너지 하이브리드 시스템을 도입하여 최적화 운영모델을 개발하고자 한다. 특히 신재생에너지 중에서도 입지제약이 작고 열과 전기를 동시에 생산할 수 있는 연료전지(Fuel Cell)발전과 대표적인 신재생에너지인 태양광(Photovoltaic)발전과 심야발전시 전력을 저장하여 주간에 전력을 방출 할 수 있는 ESS(Energy Storage System)의 조합을 검토하였다. 이에 따른 최적화 모델 선정은 HOMER(Hybrid Optimization of Multiple Energy Resources) 프로그램을 활용하였다. 경제성 분석을 수행한 결과, 순 현재비용(NPC) 측면에서는 기존의 99MW 열병합발전이 가장 경제적이지만 신재생에너지를 사용하여 발생되는 탄소배출권 거래와 REC(Renewable Energy Certificate) 거래를 포함한 측면에서는 99MW의 CHP와 5MW의 연료전지, 521kW의 태양광을 하이브리드 시켜서 전력과 열을 공급하는 것이 99MW의 CHP 열병합발전만으로 전력과 열을 공급하는 것보다 최대 2,475억원 경제적인 것으로 나타났다. 구역전기사업에서 최적화 공정모델로 연료전지와 신재생에너지 하이브리드 시스템을 도입함으로써 경제성을 개선시킬 수 있는 결과를 확인하였다.

열분해에 의한 카펫의 안정성에 관한 연구 (A Study on the Stability of Carpet by Thermal Decomposition)

  • 박근호;이기철
    • 한국응용과학기술학회지
    • /
    • 제23권2호
    • /
    • pp.147-152
    • /
    • 2006
  • The accidents occurred by unstable material which is easily exploded or burnt up were caused by heat and collision under the condition of relatively low temperature without oxygen, have been reported frequently. However, the amount of the unstable material is getting higher by development of fine ceramic research area even though its dangerous characteristic is disregarded. This research studied a heat stability and measured boiling point of various carpet material. Carpet has been used in home as well as general indoor usage. Now a day, carpet material which is hardly burnt has been on commercial, but its detailed unstable conditions is not mentioned. This research reports the measurement of the initial temperature of generation heat and heat-radiation change on differential scanning calorimeter (DSC). The DSC data of nylon bulked continuous filament (N-BCF) yam 100%, nylon (NY), poly propylene (PP), and a new material named polytrimethylene terephthalate (PTT) are studied and researched about the effect of them using TGA, furnace, and direct-burning experiment.

기초자치단체의 폭염으로 인한 온열 및 심뇌혈관질환 부담 (Municipal Disease Burden Attributable to Heat Wave)

  • 이수형;신호성
    • 보건교육건강증진학회지
    • /
    • 제31권4호
    • /
    • pp.51-62
    • /
    • 2014
  • Objectives: The objective of study was to calculate the municipal level environmental burden of disease (EBD) due to heat wave. Methods: The data used were Korea National Health Insurance 2011 claim data and 2011 death registry. Heatwave related diseases included hypertensive heart diseases, ischemic heart diseases, cerebrovascular disease, and heat related illness. According to the method that WHO proposed, the study computed population-attributable fraction with relative risk which come from previous study and proportion of exposure which the study calculated with historical meteorology data. Results: The Average of 251 municipal EBD was 2.11 per thousand persons. The value of years lost due to disability was 11 times higher than that of years of life lost. On average EBD of county and southern geographical areas tended to be higher than those of District or city areas. The relationship between municipal deprivation index (composite deprivation index) and EBD showed the positive association, which means that the worse deprived municipal is, the higher EBD takes. Conclusions: Climate change is getting one of the major risk factors of cardio-cerebrovascular disease, which is the second leading cause of death. The study results suggested the urgent policy planning and reaction of climate change adaptation.

스크류 열펌프 시스템의 운전제어 방안에 관한 연구 (A Study on the Operating Control of a Heat Pump System with Screw Compressors)

  • 박준택;이영수;김지영;채규정;양희정
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.168-172
    • /
    • 2013
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump system, which will be used for district heating and cooling. In this study, two issues of the system operating control were investigated. The first issue is the mode switching control from 1-stage to 2-stage. A stable 2-stage heating operation is guaranteed, only if the load-side water inlet temperature is over a certain value, where the 1-stage heating operation should be done first from a cold start. The second issue is oil level control. An oil shortage problem in the low stage compressor, which depends on the degree of suction superheat, was solved by a proper oil level control scheme.

기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구 (A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion)

  • 이관호;김남규;박진철;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제25권2호
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.

스크류 2단 압축 열펌프 시스템의 운전 제어 방안에 관한 연구 (A Study on the Operating Control of a 2-Stage Heat Pump System with Screw Compressors)

  • 김지영;백영진;이영수;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.501-505
    • /
    • 2006
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump, which will be used in district heating and cooling. Two issues on the system control were investigated in this study, A stable 2-stage heating operation is guaranteed only if the load-side water inlet temperature is over a certain value, to where the 1-stage heating operation should be done first from a cold start. An oil shortage problem in low stage compressor, which depends on the degree of suction superheat, was solved by the proper oil level control scheme.

  • PDF

집단에너지 사업자간의 열연계 메커니즘 구성에 의한 최적 열연계 산정 알고리즘 개발 (Development of Optimal Thermal Transfer Calculation Algorithm by Composition of Thermal Transfer Mechanism among Integrated Energy Operators)

  • 김용하;김승희;현승연
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.57-66
    • /
    • 2017
  • 열은 전력과 같이 이동속도가 빠르지 못하고 전력에 비해 손실이 비교적 크게 발생하므로 전력거래와 같이 한개의 운용센터를 두고 열 연계 시스템을 운용하는 것은 현실성이 없다. 현재 열 연계가 모두 이루어지고 있는 한국지역난방공사의 경우에도 인접한 2~4개 정도의 열병합발전소간에만 열 거래가 이루어지고 있는 실정이다. 따라서 본 논문에서는 열 거래를 위한 통합운용센터를 몇 개의 권역으로 나누어 각 권역마다 권역의 Hub 통합운용발전소를 두고 운용하는 것이 열매체의 특성을 반영하는데 적정하고 타당한 것으로 판단하여 집단에너지 사업자간 열 연계 메커니즘을 제안하였다. 제안된 메커니즘에 최적으로 열 거래를 행할 수 있는 알고리즘을 개발하고 이를 실제 사업자에 적용하여 제안한 알고리즘의 유용성을 검증하였다.