• 제목/요약/키워드: Distribution safety

검색결과 3,085건 처리시간 0.03초

DACUM(Developing A Curriculum)을 이용한 식품 안전 전문가 직무 분석 (Job Analysis of Food Safety Specialist Based on the Developing A Curriculum(DACUM) Method)

  • 송태희
    • 한국식품영양학회지
    • /
    • 제22권1호
    • /
    • pp.123-131
    • /
    • 2009
  • The purpose of this study was to define the job description for food safety specialist, and to describe the duties and tasks of the job based on the detailed analysis of specific food safety work performed by dietitians. The job analysis was 8 professional panels and a Developing A Curriculum(DACUM) facilitator. The research was done in order to fully define the task element, process, and sequence of a food specialist and was completed by DACUM analysis. The job definition of food safety specialist is one who manages food safety through analysis, safety evaluation, inspection, and hazard blocking in all processes related to the purchase, distribution, storage, manufacture, and marketing of foods and food materials. The job description on the DACUM research chart for food safety specialist contained 7 duties and 79 tasks. Its duties were defined as the specific and independent work of a food safety specialist, and were composed of 7 duties, i.e. hazard analysis of foods and related affairs, safety evaluation of purchased food materials, safety management of food/food materials distribution/storage, safety management of food manufacture, safety examination of food marketing, administration affairs on food safety, and self-development. For the future, this study suggests a curriculum, that shall be basis of program planning and food safety operation for subjects within many schools.

외관불량 배전용 콘크리트전주 건전도 평가지표 개발 (A Development of Soundness Evaluation Index for Poor Appearance Distribution Concrete Poles)

  • 왕윤찬
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.35-44
    • /
    • 2014
  • This study was to secure the safety of poor appearance distribution concrete poles effectively and to reduce the replacement costs of them by developing a soundness evaluation index. The researcher of this study investigated poor appearance types of concrete pole, collected 53 of test samples, and tested pole strength. As a result of strength test, only 17 percent of poor appearance concrete poles were below 2.0 of safety factor spec. As results of multiple regression analysis, it is verified that surface air void, horizontal crack, net-shaped crack, elapsed year, vertical crack, and deterioration in concrete compressive strength have statistically negative effects on safety factor of concrete poles in a significant level. The researcher set up a soundness evaluation index by using multiple regression equation, and suggested that poor appearance concrete poles should be replaced or reinforced only in case of soundness evaluation score of 150 or above.

배전용 접지전극의 안전성 분석 장치 구성 (The Construction of Safety Measurement Equipment of Grounding Electrode for Distribution System)

  • 강문호;박영근;장상옥;왕윤찬;이흥호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.218-221
    • /
    • 2005
  • Grounding electrodes as discharge paths to the earth are normally used to ensure the safety of human body and facilities from the over-voltages in distribution power system, and each grounding mode has a prescribed ground resistance value respectively which is applied by the utilities. As the various electrodes for distribution power system are recently developing to improve the performance of them and resolve the problem of space restriction, it is necessary to measure and investigate the safety of human body of developed electrodes. Therefore, in this paper, we provide briefly a technical comparison of two standards, i.e. IEEE Std 80 and the IEC 479-1, and describe the configuration of safety measurement system which can measure the step voltage and the touch voltage of grounding electrodes based on IEEE Std 80.

  • PDF

전력설비 안전성 확보를 위한 GIS(가스절연개폐장치) 검사수행 절차 및 방법 (The Inspection Procedure and Method of GIS to Guarantee the Safety of Power Facility)

  • 박준성;황광수;김진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.361-364
    • /
    • 2015
  • 본 논문은 전기사업법 제61조의 공사계획인가 및 신고대상인 차단기에 대하여 동법 제63조에 의거해 실시하는 사용전검사의 항목 및 검사수행 방법에 대하여 서술하였다. 차단기는 전력계통을 이상전압에서 보호하기 위한 밀폐형 개폐장치로서 전기사업용 전기설비인 변전소에 설치되는 차단기는 대부분 GIS(Gas Insulated Switchgear)화 되고 있는 실정이다. GIS는 정상전류의 차단, 설비사고의 억제 및 파급사고 확산방지에 중추적인 역할을 수행하고 있기 때문에 그 중요성은 더욱 더 높아지고 있다고 볼 수 있다. 이에 핵심 전력설비인 GIS의 사용전 검사항목 및 검사수행 방법을 고찰함으로써 안정적인 전력공급과 전력계통의 신뢰도 제고에 기여하고자 한다.

  • PDF

고속도로 터널 내 화재사고 발생 시 대피행동 지연 요인에 관한 연구 (A Study on the Delayed Factors in Evacuation Behavior in the Case of Fire Accidents in Highway Tunnels)

  • 조재환
    • 대한안전경영과학회지
    • /
    • 제24권4호
    • /
    • pp.143-148
    • /
    • 2022
  • This paper attempted to analyze the correlation between the risk image of the evacuees in the tunnel and the variables that affect the evacuation behavior due to the closed feeling. As to whether there is a difference in the level of recognizing the tunnel risk image according to the distribution of jobs, the null hypothesis was rejected at the significance probability of 0.002, so it can be said that the level of recognition of the tunnel risk image varies depending on the job group. In the distribution difference between gender and tunnel risk image recognition level, the significance probability was 0.012, indicating that the null hypothesis was rejected, indicating that the tunnel risk recognition distribution according to gender was different. As a result of analyzing the distribution difference between the tunnel's closed feeling and the tunnel risk perception level, the significance probability was 0.001, and the null hypothesis was rejected, indicating that there was a difference in the tunnel risk image level.

최적 교통분포를 고려한 해상교량의 안전 통항 폭에 관한 연구 (A Study on the Safety Navigational Width of Bridges Across Waterways Considering Optimal Traffic Distribution)

  • 손우주;문지하;구정민;조익순
    • 한국항해항만학회지
    • /
    • 제46권4호
    • /
    • pp.303-312
    • /
    • 2022
  • 해상교량은 선박의 통항 안전성 관점에서 가항수역을 줄이는 간섭요인으로 작용한다. 본 연구에서는 선박의 안전한 통항을 위해 최적 통항분포에 기반한 안전 통항폭을 분석하였다. 해상교량을 통항하는 선박의 안전 통항 폭에 대한 분석을 위해 AIS data에 기반한 선박교통분포를 조사하여 K-means clustering을 통해 선박을 크기에 따라 분류하였다. 군집화된 데이터에 대하여 최적분포 분석을 한 결과, 인천대교와 부산항대교에서는 대수정규분포, 목포대교와 마창대교에서는 정규분포가 최적분포에 가까운 것으로 분석되었다. 대수정규분포와 정규분포를 기준으로 선박 안전 통항 범위를 신뢰구간의 95%로 가정하여 분석한 결과, 인천대교의 경우 정규분포와 대수정규분포 간의 차이가 64~97m로 가장 큰 것으로 나타났으며, 최소 차이는 10m로 마창대교에서 나타났다. 이에 따라, 인천대교의 경우에는 정규분포보다 대수정규분포로 안전 통항 폭을 제시하는 것이 적합한 것으로 분석되었다. 타 교량의 경우에는 정규분포와 대수정규분포 간의 통항 폭 차이가 크지 않기 때문에 둘 중 어떤 분포를 사용해도 유사한 결과를 얻을 수 있는 것으로 분석되었다. 위 결과를 토대로, 해상교량의 안전통항 범위를 제시한다면 선박의 안전한 운항 및 사고 예방에 도움이 될 것이다.

환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구 (A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities)

  • 전용한;한상필
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

물류 안전과 기업 생산성 향상에 대한 사례 연구 (A case study of logistics safety and enterprise productivity innovation)

  • 김순조;안태용;강경식
    • 대한안전경영과학회지
    • /
    • 제9권5호
    • /
    • pp.7-16
    • /
    • 2007
  • Safety and health problem are essential element of enterprise productivity Innovation within 21th century Global struggle for existence. It is not only to protect workers but it also should prevent workers from various forms of danger. In this paper, specifically, through Case Study about safety and damage government official System course danger exclusion technique of physical distribution, I wish to present direction of continuance possibility management hereafter.

지하상가 침수 시 전기설비 전위분포 해석 (The Analysis of Potential Distribution for Submerged Electrical Fittings in an Underground Shopping Street)

  • 정진수;정종욱;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2072-2073
    • /
    • 2007
  • This paper describes the analysis of potential distribution and leakage current magnitude around the electrical fittings submerged in an underground shopping street. In the experiment, a couple of electrical utilities(outlet, fluorescent lamp) were submerged in a concrete water bath. The experimental results are expected to be utilized for the risk assessment and the safety countermeasure against the electric shock.

  • PDF

지중송전선로 안전관리 방안 (OF케이블) (A Study on the Safety Checking and Testing method of the underground power transmission line (OF Cable))

  • 최종수;박강서;전준만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.429-434
    • /
    • 2009
  • 본 논문에서는 지중송전케이블의 안전관리방안에 대하여 정리하였고, 그에 따른 전기재해의 예방은 안정적인 전력공급과 설비운용에 있어 큰 비중을 차지한다. 최근 전력구내 OF케이블에서 화재가 발생하여 자칫 전력공급계통 마비로 이어져 광역정전과 심각한 사회문제를 초래시킬 수 있었던 바, 엄정한 검사를 통하여 이와 같은 유사사례 사고를 미연에 방지함은 물론 OF케이블에 대한 검사능력 배양과 선진기술 축적으로 향후 전기안전관리 향상 및 전기재해를 예방함으로써 안정적인 전력공급을 도모하기 위함이다.

  • PDF