• Title/Summary/Keyword: Distribution safety

Search Result 3,042, Processing Time 0.034 seconds

Analyzing the Importance and Performance of Sanitation Management within Childcare Center Foodservice Facilities in Gyeongbuk Province (경북 지역 보육 시설 급식소의 위생 관리에 대한 중요도-수행도 조사)

  • Jung, Hyeon-A;Kim, An-Na;Joo, Na-Mi;Paik, Jae-Eun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.3
    • /
    • pp.385-391
    • /
    • 2011
  • The purpose of this study was to analyze the importance and performance of sanitation management within childcare center foodservice facilities in Gyeongbuk province. The survey involved 248 people who participated in the food hygiene and safety education for childcare center managers in Gyeongbuk province from June to July 2010. A total of 236 survey papers were analyzed statistically by SPSS program. By the method, t-test and importance-performance analysis (IPA) was performed. Among the respondents, facility managers are 40s (41.9%) which accounted the most percentage, and for the type of facility, the largest amount was home (39.9%). The number of preschool children who are under 20 people accounted for 45.3% and food service staffs were accounted for 36.7%. No significant differences were observed for the four items on the IPA, except for the topics "the immediate deal with trash and leftover food" and "minimizing time (within 2 hours) for distribution after cooking" (p<0.001). The average score on the IPA was 4.14 points, and the average score for the importance of the evaluation was 4.49 points out of 5. Finally, childcare facility managers are aware of the importance that is lower than can be done. The results suggest that continuing education is necessary to administrators to manage the health care facility effectively.

Microbial quality of fresh vegetables in restaurants around school (학교주변식당 신선 채소류의 미생물 오염도 조사)

  • Jo, So Hyun;Chung, Hyun-Jung;Lee, Seong Hee;Hwang, Su Jung;Om, Ae-Son;Eun, Jong-Bang
    • Food Science and Preservation
    • /
    • v.20 no.3
    • /
    • pp.424-428
    • /
    • 2013
  • Microbiological contamination of 4 vegetables (garlic, red pepper, perilla leaf and lettuce) collected from 10 restaurants around university was examined. The vegetables were evaluated for total plate count, coliforms, psychrophiles, yeast, and Staphylococcus aureus. The results of total plate count showed the highest value as $5.4{\pm}0.69$ log CFU/g in lettuce, following by $4.8{\pm}1.53$ log CFU/g in red pepper, $4.5{\pm}1.65$ log CFU/g in perilla leaf and $3.4{\pm}1.27$ log CFU/g in garlic. The contamination level of coliforms and psychrophiles were highest in red pepper with maximum as 4.7 log CFU/g and 8.2 log CFU/g, respectively. Red pepper of psychrophiles showed the highest average value as $5.0{\pm}1.82$ log CFU/g followed by $4.2{\pm}1.91$ log CFU/g in lettuce, $4.7{\pm}1.55$ log CFU/g in perilla leaf and $2.4{\pm}2.10$ log CFU/g in garlic. The average number of yeasts were highest in perilla leaf with $4.4{\pm}1.41$ log CFU/g and were lowest in garlic with $0.9{\pm}1.41$ log CFU/g. The contamination level of S. aureus was detected in 27 samples among the total 40 samples with the range of 0.5-5.2 log CFU/g. In conclusion, the microbial quality of the fresh vegetables evaluated in this study was not very good. Therefore, it needs to be enhanced through the good sanitation management and production and distribution methods to improve the safety of fresh vegetables.

Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma (자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용)

  • Chung, Woong-Ki;Nah, Byung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.57-64
    • /
    • 1997
  • Purpose : Before we report the results of curative radiotherapy in cervix cancer patients, we review the significance and safety of our dose specification methods in the brachytherapy system to have the insight of the potential Predictive value of doses at specified points. Matersials and Methods : We analyze the 리5 cases of cervix cancer patients treated with intracavitary brachytherapy in the lateral simulation film we draw the isodose curve and observe the absorbed dose rate of point A, the reference point of bladder(SBD) and rectum(SRD). In the sagittal view of Pelvic MRI film we demarcate the tumor volume(TV) and determine whether the prescription dose curve of point A covers the tumor volume adequately by drawing the isodose curve as correctly as possible. Also we estimate the maximum Point dose of bladder(MBD) and rectum(MRD) and calculate the inclusion area where the absorbed dose rate is higher than that of point A in the bladder(HBV) and rectum(HRV), respectively. Results : Of forty-five cases, the isodose curve of point A seems to cover tumor volume optimally in only 24(53%). The optimal tumor coverage seems to be associated not with the stage of the disease but with the tumor volume. There is no statistically significant association between SBD/SRD and MBD/MRD, respectively. SRD has statistically marginally significant association with HRV, while TV has statistically significant association with HBV and HRV. Conclusion : Our current treatment calculation methods seem to have the defect in the aspects of the nonoptimal coverage of the bulky tumor and the inappropriate estimation of bladder dose. We therefore need to modify the applicator geometry to optimize the dose distribution at the position of lower tandem source. Also it appears that the position of the bladder in relation to the applicators needs to be defined individually to define 'hot spots'.

  • PDF

Distribution and Behavior of $^{137}Cs$ According to topography and nature of the soil around Yeong-Gwang NPPs, (영광원자력발전소 주변의 지형 및 지질에 따른 $^{137}Cs$ 분포 및 거동에 관한 연구)

  • Han Sang-Jun;Lee Goung-Jin;Kim Hee-Geun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.4
    • /
    • pp.271-278
    • /
    • 2004
  • This paper shows our experiment is performed to understand the exposure tendency of $^{137}Cs$ according to the height of area and also, to supplement it by considering chemical characters of $^{137}Cs$ exposed to the soil. The samples we use for this experiment are from the general flat area of Yeonggwang county where it has NPPs, the high places of Keumjung & Bulgap mountains, and Naejan mountain where it is quite far from the NPPs. The data from this experiment show that the exposure of $^{137}Cs$ is not harmful since its range is around 252 Bq/kg-dry in most of sampled soils such as from the general flat area, the high place of Keumjung mountain where is 2 km away from the NPPs, the other high place of Bulgap mountain where is about 20 km away from the NPPs, and Naejan mountain where it is far from the NPPs. Not like the general flat area, however, the data show that the higher the area is the more $^{137}Cs$ is exposed. That is, at the top of mountains, the more $^{137}Cs$ is exposed compared to at the bottom area. It is almost $2{\~}6$ times more than the general flat area of Yeonggwang county where it has NPPs. The data also show that the spread of $^{137}Cs$ is deeply related to the geographical(the height of area, rainfall, etc..) factors and chemical factors of soils. As the geographical factors, there are far more chances to be exposed of $^{137}Cs$ at the high area of mountains through the air compared to at lower area and therefore, we can get more high-leveled readings of $^{137}Cs$ at the high area while it is low-leveled ones at the general flat area even if both of them have the same soil conditions. Regarding the chemical factors of soil, it is clarified that the CEC is the key factor. The CEC means the capability of sticking $^{137}Cs$ accumulated into the soil. Hence, the more CEC it has the more high-leveled readings of $^{137}Cs$ we get under the same geographical condition.

  • PDF

Quality Changes of Fresh-Cut Leafy and Condiment Vegetables during Refrigerated Storage (신선편이 엽채류 및 조미채소류의 냉장저장 중 품질변화)

  • Kim, Su-Jin;Sun, Shih-Hui;Kim, Gi-Chang;Kim, Haeng-Ran;Yoon, Ki-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1141-1149
    • /
    • 2011
  • The objective of this study was to analyze quality changes during storage of fresh-cut produce (leafy vegetables and condiment vegetables) as a function of packaging and storage temperature. Fresh-cut produce was washed using a three step cleaning process and was packed in vacuum packaging (green onion, hot pepper, onion, baechu) and perforated film packaging (buchu and perilla leaf). The effects of packaging method and storage temperature on quality of fresh-cut produce were determined by analyzing total plate counts, E. coli, coliform groups, moisture content, pH, Aw, surface color, and exterior quality during storage at 4 and 10$^{\circ}C$. According to the results, surface color change and microbial growth were delayed during storage at 4$^{\circ}C$. Additionally, E. coli was not detected during storage. Generally, moisture content decreased in the perforated film packaging. Changes in surface quality such as skin browning, softening of tissue and chlorosis at 4$^{\circ}C$ were inhibited, whereas rapid vacuum annealing and changes in color and flavor were observed in the sample stored at 10$^{\circ}C$. The result indicated that overall quality of the fresh-cut produce at 4$^{\circ}C$ was well maintained. The perforation in packing materials did not significantly increase the number of microorganisms on buchu and perilla leaf. The proper packaging methods and temperature may beneficial effect on microbial safety, quality and thus result in longer shelf-life fresh-cut vegetables during distribution.

Clinical Usefulness of a Totally Laparoscopic Gastrectomy (전(全)복강경하 위절제술의 임상적 유용성)

  • Kim, Jin-Jo;Kim, Sung-Keun;Jun, Kyong-Hwa;Kang, Han-Chul;Song, Kyo-Young;Chin, Hyung-Min;Kim, Wook;Jeon, Hae-Myung;Park, Cho-Hyun;Park, Seung-Man;Lim, Keun-Woo;Park, Woo-Bae;Kim, Seung-Nam
    • Journal of Gastric Cancer
    • /
    • v.7 no.3
    • /
    • pp.132-138
    • /
    • 2007
  • Purpose: In Korea, the number of laparoscopy-assisted distal gastrectomies for early gastric cancer patients has been on the increase. Although minimally invasive surgery is more beneficial, no reported case of a total laparoscopic gastrectomy has been reported because of difficulty with intracorporeal anastomosis. This study attempts, through our experience, to determine the safety and feasibility of a total laparoscopic gastrectomy with various types of intracorporeal anastomosis using laparoscopic linears stapler in treating early gastric carcinomas. Materials and Methods: We investigated the surgical results and clinicopatholgical characteristics of 81 patients that underwent a totally laparoscopic distal gastrectomy at our department between June 2004 and May 2007. The intracorporeal anastomoses were performed by using laparoscopic linear staplers. Results: The mean operative time was 287 minutes, the mean anastomotic time was 40 minutes, and the mean number of laparoscopic linear staplers used for an operation was 7.5. The mean time to the first flatus, the first food intake, and discharge from hospital was 2.9, 3.6, and 10.3 days respectively. There were 11 cases of postoperative complications, but no case of postoperative mortality or conversion to an open procedure. In 75 patients with an adenocarcinoma, the mean number of lymph nodes harvested was 38.1 and the stage distribution was as follows: stage I, 72 patients; stage II, 2 patients; stage IV, 1 patient. During the mean follow-up period of 14 months, 5 patients died of other causes and there were no cases of cancer recurrence. Conclusion: A total laparoscopic gastrectomy with intracorporeal anastomosis by using a laparoscopic linear stapler was found to be safe and feasible. We were able to obtain acceptable surgical outcomes in terms of minimal invasiveness.

  • PDF

Pharmacokinetics of oxolinic acid in cultured olive flounder Paralichthys olivaceus by oral administration, injection and dipping (Oxolinic acid의 경구투여, 주사 및 약욕에 따른 넙치, Paralichthys olivaceus 체내 약물동태학적 특성)

  • Jung, Sung-Hee;Choi, Dong-Lim;Kim, Jin-Woo;Jo, Mi-Ra;Jee, Bo-Young;Seo, Jung-Soo
    • Journal of fish pathology
    • /
    • v.22 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • The pharmacokinetic properties of oxolinic acid (OA) were studied after oral administration, intraperitoneal injection and dipping to cultured olive flounder, Paralichthys olivaceus (average 90 g, $23{\pm}1{^{\circ}C}$). Plasma samples were taken at 3, 5, 10, 15, 24, 30, 48, 96 and 144 h post-dose. In oral dosage at 15, 30 and 60 ㎎/㎏, the peak plasma concentrations of OA, which attained at 10~15 h post-dose, were 1.92, 2.45 and 3.72 $\mu{g}/m\ell$, respectively. In intraperitoneal injection with 10 and 20 ㎎/㎏, the peak plasma concentrations of OA, which attained at 10 h post-dose, were 4.1 and 4.8 $\mu{g}/m\ell$, respectively. In dipping in 30 and 50 ppm for 1 h, peak concentrations were observed at 5 h and 30 h post-dose, were 0.22 and 0.38 $\mu{g}/m\ell$, respectively. The kinetic profile of absorption, distribution and elimination of OA in plasma were analyzed fitting to a one-compartment model by WinNonlin program. Calculated parameters for a single oral dosage of 15, 30 and 60 ㎎/㎏, respectively, were: AUC (the area under the concentration-time curve)=70.93, 120.0 and 141.86 $\mu{g}$ $h/m\ell$ $T_{max}$ (time for maximum concentration)=16.22, 20.39 and 17.33 h; $C_{max}$ (maximum concentration)=���D1.61, 2.40 and 3.01 $\mu{g}/m\ell$. Following intraperitoneal injection of 10 and 20 ㎎/㎏, these parameters were AUC=184.7 and 315.92 $\mu{g}$ $h/m\ell$ $T_{max}$=5.91 and 6.26 h; $C_{max}$=4.19 and 4.45 $\mu{g}/m\ell$. Following dipping at 30 and 50 ppm, these parameters were AUC=17.58 and 21.69 $\mu{g}$ $h/m\ell$ $T_{max}$=19.08 and 31.43 h; $C_{max}$x=0.22 and 0.25 $\mu{g}/m\ell$.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Calculation Method of Oil Slick Area on Sea Surface Using High-resolution Satellite Imagery: M/V Symphony Oil Spill Accident (고해상도 광학위성을 이용한 해상 유출유 면적 산출: 심포니호 기름유출 사고 사례)

  • Kim, Tae-Ho;Shin, Hye-Kyeong;Jang, So Yeong;Ryu, Joung-Mi;Kim, Pyeongjoong;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1773-1784
    • /
    • 2021
  • In order to minimize damage to oil spill accidents in the ocean, it is essential to collect a spilled area as soon as possible. Thus satellite-based remote sensing is a powerful source to detect oil spills in the ocean. With the recent rapid increase in the number of available satellites, it has become possible to generate a status report of marine oil spills soon after the accident. In this study, the oil spill area was calculated using various satellite images for the Symphony oil spill accident that occurred off the coast of Qingdao Port, China, on April 27, 2021. In particular, improving the accuracy of oil spill area determination was applied using high-resolution commercial satellite images with a spatial resolution of 2m. Sentinel-1, Sentinel-2, LANDSAT-8, GEO-KOMPSAT-2B (GOCI-II) and Skysat satellite images were collected from April 27 to May 13, but five images were available considering the weather conditions. The spilled oil had spread northeastward, bound for coastal region of China. This trend was confirmed in the Skysat image and also similar to the movement prediction of oil particles from the accident location. From this result, the look-alike patch observed in the north area from the Sentinel-1A (2021.05.01) image was discriminated as a false alarm. Through the survey period, the spilled oil area tends to increase linearly after the accident. This study showed that high-resolution optical satellites can be used to calculate more accurately the distribution area of spilled oil and contribute to establishing efficient response strategies for oil spill accidents.

A study on the structure of the Three storied Stone pagoda in Gameunsa Temple site (감은사지 삼층석탑 구조)

  • Nam, si-jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.38
    • /
    • pp.329-358
    • /
    • 2005
  • The Three storied Stone pagoda in Gameunsa Temple site, one of the early staged stone pagodas, has been known as a standard for Silla stone pagodas. A stone pagoda is not only a stone art work and but also a stone structure. Most studies and investigation of the stone pagoda has done mainly based on style and chronological research according to an art historical view. However, there is not an attempt to research the stone pagoda as a stone architecture. Most Korean experts at the stone pagoda has art history in their background. Engineers who can understand the structure of the stone pagoda are very limited. More architectural and engineering approach is need to research not only art historial understanding but also safety as a structure. We can find many technical know-how from our ancestors who made stone pagodas. 1. To reduce any deformation such as relaxation and sinking of BuJae which is caused by a heavy load, the BuJae (consist of a foundation stone and lower stereobates) should be enlarged. 2. A special construction method for connection between Myonsuk and Tangjoo was invented. This unique method is not used any longer after the Three storied Stone pagoda in Gameunsa Temple site. 3. The upper BuJae and the lower BuJae are missed each other by making a difference of Okgaesuk and Okgaebatchim in size. It is done for a distribution of perpendicular load and a prevention for relaxation of BuJae. 4. The center of gravity in the BuJae is located to the center of the stone pagoda by trimming the upper surface of the Okgaebatchim into a convex shape. The man who made stone pagodas had excellent knowledge on the engineering and techniques to understand the structure of the stone pagodas. We can confirm it as follows: the enlarged BuJae, dislocated connection between upper Bujae and lower BuJae, and moving the center of gravity close to the center of the stone pagoda.