• Title/Summary/Keyword: Distribution limit

Search Result 1,175, Processing Time 0.03 seconds

A Novel Fault Location Method for a Line to Line Fault Using Inverse Theorem of Matrix on Electric Power Lines (행렬의 역정리를 이용한 전력공급 선로의 상간단락 사고지점 검출 방법)

  • Lee Duck-su;Choi Myeon-song;Hyun Seung-ho
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1321-1324
    • /
    • 2004
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. In this paper, a novel fault location algorithm is suggested for a line to line faults using inverse theorem of matrix on electric power lines. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any electric power system but are particularly useful for unbalanced distribution systems. The simulation results oriented by the real distribution system are presented to show its effectiveness and accuracy.

  • PDF

A Study on the Computation of Hull Temperature Distribution and Boil off Ratio of MRV Type LNG Carrier (MRV형 LNG선의 선체온도분포 및 증발률 산정에 관한 연구)

  • 천병일;김용모;김경근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.986-996
    • /
    • 1994
  • Insulation system of LNG carrier has made important roles such as maintaining a proper Boil off Ratio(BOR) for the cargo and avoiding the excessive low temperature of the adjacent inner hull beyond the permissible limit. At the same time, safety and economy of the LNG transportation by the ship are connected with the performance of the insulation system. Also, thermal insulation system of LNG carrier is one of the most advanced technique with the structure analysis of tank, welding and assembling. In this study a computer program is developed to calculate the hull temperature distribution and BOR, which are important factors in thermal design for the Moss Rosenberg Verft spherical tank type LNG carrier. Detailed results for hhull temperature distribution close to LNG tank, BOR and the thickness effect of insulation material are reported in this paper in the range of standare design sea condition.

An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation (154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

A study on capacitive transformer (용량성배전변압기에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • v.18 no.2
    • /
    • pp.7-14
    • /
    • 1969
  • From the first customer located right at the substation to the last customer at the end of the line, voltage must be held within close limits, so the voltage regulation is more important than the thermal limit. On a typical distribution system during the peak load period, the voltage drop may be serious enough to cause unsatisfactory operation of home appliances in the residential area, and present many problems to manufacturing industries, where the voltage must be maintained within close limits to insure smooth operation. Among all the factors contributing to voltage drop in the distribution system, the voltage drop in the distribution transformer may account for 30% of this figure. If we can eliminate this factor, the power companies can provide better quality electricity to more customers with the existing distribution facilities, thus saving on initial investment costs. Taking all these problems into consideration, the author undertook the design of a capacitive transformer which would give zero voltage drop at rated load and at 80% lagging power factor while incorporating overload features to withstand 400% overload for at least 100 seconds. The following are the results obtained through design, manufacture and test of an initial experimental transformer built with these specific purposes.

  • PDF

A Study on the Superconducting Fault Current Limiter in the Simple $3{\phi}$ Power System (유도형 고온 초전도 한류기의 단순 3상 계통 적용에 대한 연구)

  • Lee, S.J.;Joo, M.S.;Lee, C.J.;Lee, J.K.;Ko, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.253-255
    • /
    • 1997
  • This paper, which is one of the researches to limit high fault-current, treats the application of an inductive High Tc Superconducting Fault Current Limiter(HTSFCL) to distribution systems. In case that the inductive HTSFCL is applied to distribution systems, this paper presented the usefulness and the commercial possibility of it through computer simulation. If the inductive HTSFCL is established in distribution systems, after fault, it limits fault current effectively within a few millisecond, so it contributes to stability of power distribution system. Especially as the system with the HTSFCL is compared with the system without it, the system is improved in stability.

  • PDF

Analysis of Production Process of Fine Size Fraction of Korean Kaolin by Ball Mill Grinding I (Ball Mill 분쇄에 의한 고령토의 미분성분 생성과정의 해석 I)

  • 심철호;김상필;서태수
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.4
    • /
    • pp.35-40
    • /
    • 1986
  • The production process of a fine size fraction of Korean kaolin by ball milling is studied in this paper by analyzing the size distribution the size distribution of products with the Rosin-rammle formular and the rate process of cumulative size fractions with Alyavdin-Chujyo's formular. The size distribution is found to be divided in three regions a coarser part influenced by feed size an intermediate part where the size distribution shows a clear straight line relationship on Rosin-Rammler chart and the finest part with the ultimate limit of fineness by ball milling. Alyavdin-Chujyo's relationship is found to be valid over a very wide range of milling conditions. For different feed sizes the Alyavdin-Chujyo's relationship gives a group of straight lines with a common intersection point which can be defined as the limiting point of the persistent component region.

  • PDF

A Study on the Protection of Power Distribution System with the Distributed Generator and Superconducting Fault Current Limiter (분산전원이 도입된 배전계통에 초전도한류기 적용시 계통보호 시스템의 영향에 관한 연구)

  • Kim, Myong-Hyon;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1226-1231
    • /
    • 2012
  • The demand for electrical power has been significantly increased to satisfy the customers. As a result, a power distribution system have been advanced by power system's interconnection, installation of distributed generator(DG) and so on. The improvable power distribution system included the problem of increasable fault current. Superconducting fault current limiter (SFCL) is one of the solutions to limit a fault current. Therefore, to solve the problem of fault current by SFCL, simulation was progressed and the simulation used a PSCAD/EMTDC.

A Study on the Improvement of Life Safety Code for Logistics Warehouse Facilities (물류창고 시설의 인명안전기준 개선 방안에 관한 연구)

  • Kim, Yun-Seong;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.98-99
    • /
    • 2021
  • The number of fires in the Korean distribution warehouse increased by about 350 from 1,070 in 2014 to 1,416 in 2020. In addition, the fire load increases with the scale of the distribution warehouse, and even if the automatic sprinkler operates, there is a limit to the direct intrusion of the water source into the ignition source, and the detector is often installed on a high ceiling. The sensing time is often delayed. In order to improve the fire safety of such distribution warehouses, the US NFPA stipulates in detail the contents related to the facility, such as sprinkler water discharge standards, rack-type warehouse installation height restrictions, and regulations on collection and equipment. However, in Japan, the goods loaded inside the distribution warehouse are not classified in detail, and it is considered that the fire safety for the distribution warehouse is low due to the relaxation regulations of the fire prevention section. Therefore, in this study, common problems are classified into material, spatial, and safety management characteristics through the cases of distribution warehouse fires that occurred in Korea and abroad, and the problems related to distribution warehouses in Korea and abroad are compared and analyzed. And present basic materials for improving the life safety standards of future distribution warehouse facilities.

  • PDF

Two-sample chi-square test for randomly censored data (임의로 관측중단된 두 표본 자료에 대한 카이제곱 검정방법)

  • 김주한;김정란
    • The Korean Journal of Applied Statistics
    • /
    • v.8 no.2
    • /
    • pp.109-119
    • /
    • 1995
  • A two sample chi-square test is introduced for testing the equality of the distributions of two populations when observations are subject to random censorship. The statistic is appropriate in testing problems where a two-sided alternative is of interest. Under the null hypothesis, the asymptotic distribution of the statistic is a chi-square distribution. We obtain two types of chi-square statistics ; one as a nonnegative definite quadratic form in difference of observed cell probabilities based on the product-limit estimators, the other one as a summation form. Data pertaining to a cancer chemotheray experiment are examined with these statistics.

  • PDF

A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter (고온초전도 한류기의 전력계통 적용에 관한 연구)

  • Bae, Hyeong-Thaek;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF