• Title/Summary/Keyword: Distribution Fault

Search Result 1,024, Processing Time 0.028 seconds

Fracture Developing History and Density Analysis based on Grid-mapping in Bonggil-ri, Gyeongju, SE Korea (경주시 봉길리 지역의 단열발달사 및 단열밀도 해석)

  • Jin, Kwang-Min;Kim, Young-Seog
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.455-469
    • /
    • 2007
  • The study area, Bonggil-ri, Gyeongju, SE Korea, is composed of Cretaceous sedimentary rocks, and Tertiary igneous rocks and dykes. A research on fracture developing history and density distribution was carried out on well exposed Tertiary granites. The fractures developed in this area have the following sequence; NW-SE trending duo-tile shear bands (set a), NNW-SSE trending extensional fractures (set d), WNW-ESE trending extensional or normal fractures (set b), NE-SW trending right-lateral fractures (set c), WNW-ESE trending reverse fault reactivated from normal faults (set e) and NW-SE trending left-lateral faults reactivated from shear bands (set a) under brittle condition. According to the result of fracture density analysis, the fracture density in this area depends on rock property rather than rock age, and also higher fracture density is observed around fault damage zones. However, this high fracture density may also be related to the cooling process associated with dyke intrusion as well as rock types and fault movement. Regardless of the reason of the high fracture density, high fracture density itself contributes to fluid flow and migration of chemical elements.

Design and Implementation of a Fault-Tolerant Caching System for Dynamic Heterogeneous Cache Server Networks (동적 이기종 캐시 서버 네트워크에서의 내결함성 캐싱 시스템 설계 및 구현)

  • Hyeon-Gi Kim;Gyu-Sik Ham;Jin-Woo Kim;Soo-Young Jang;Chang-Beom Choi
    • Journal of IKEEE
    • /
    • v.28 no.3
    • /
    • pp.458-464
    • /
    • 2024
  • This study proposes a fault-tolerant caching system to address the issue of caching content imbalance caused by the dynamic departure and participation of cache servers in a heterogeneous cache server network, and validates it in both real and virtual environments. With the increase of large-scale media content requiring various types and resolutions, the necessity of cache servers as key components to reduce response time to user requests and alleviate network load has been growing. In particular, research on heterogeneous cache server networks utilizing edge computing and low-power devices has been actively conducted recently. However, in such environments, the irregular departure and participation of cache servers can occur frequently, leading to content imbalance among the cache servers deployed in the network, which can degrade the performance of the cache server network. The fault-tolerant caching algorithm proposed in this study ensures stable service quality by maintaining balance among media contents even when cache servers depart. Experimental results confirmed that the proposed algorithm effectively maintains content distribution despite the departure of cache servers. Additionally, we built a network composed of seven heterogeneous cache servers to verify the practicality of the proposed caching system and demonstrated its performance and scalability through a large-scale cache server network in a virtual environment.

Service Restoration In Distribution Networks Using Cyclic Best-First Search (순환적 최적우선탐색을 이용한 배전계통의 정전복구)

  • Choi, Sang-Yule
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.162-168
    • /
    • 2004
  • Service restoration is an emergency control in distribution control centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. Therefore, it requires fast computation time and high quality solutions for load balancing. In this paper, a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a feeder load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

A Study about Emission Characteristic of LPG Vehicle on SFTP (LPG 자동차의 SFTP 모드 배출가스 특성에 관한 연구)

  • Kim, Sungwoo;Song, Hoyoung;Lee, Minho;Kim, Kiho
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.74-84
    • /
    • 2016
  • After Sep. 2017, the LEV3 emission standard will be applied to gasoline and gas vehicles in Korea. This standard has HWFET and SFTP standard as well as FTP-75. Most of LPG vehicles were certificated as SULEV in Korea. Until now, only FTP-75 standard is applying for the certification but it is expected that HWFET and SFTP are used after beginning LEV3. In this paper, 8 LPG and 4 gasoline vehicles were tested on FTP-75 and SFTP to check whether the LPG vehicles can meet LEV3 SFTP standard or not and to suggest direction of development. Most of test vehicles did not meet the SFTP standard. To make up for the fault, fuel injection control improvement is needed.

The Comparative Study of Software Optimal Release Time Based on Log-Logistic Distribution (Log-Logistic 분포 모형에 근거한 소프트웨어 최적방출시기에 관한 비교연구)

  • Kim, Hee-Cheul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.1-9
    • /
    • 2008
  • In this paper, make a study decision problem called an optimal release policies after testing a software system in development phase and transfer it to the user. When correcting or modifying the software, because of the possibility of introducing new faults when correcting or modifying the software, infinite failure non-homogeneous Poisson process models presented and propose an optimal release policies of the life distribution applied log-logistic distribution which can capture the increasing! decreasing nature of the failure occurrence rate per fault. In this paper, discuss optimal software release policies which minimize a total average software cost of development and maintenance under the constraint of satisfying a software reliability requirement. In a numerical example, after trend test applied and estimated the parameters using maximum likelihood estimation of inter-failure time data, make out estimating software optimal release time.

  • PDF

Evaluating LIMU System Quality with Interval Evidence and Input Uncertainty

  • Xiangyi Zhou;Zhijie Zhou;Xiaoxia Han;Zhichao Ming;Yanshan Bian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.2945-2965
    • /
    • 2023
  • The laser inertial measurement unit is a precision device widely used in rocket navigation system and other equipment, and its quality is directly related to navigation accuracy. In the quality evaluation of laser inertial measurement unit, there is inevitably uncertainty in the index input information. First, the input numerical information is in interval form. Second, the index input grade and the quality evaluation result grade are given according to different national standards. So, it is a key step to transform the interval information input by the index into the data form consistent with the evaluation result grade. In the case of uncertain input, this paper puts forward a method based on probability distribution to solve the problem of asymmetry between the reference grade given by the index and the evaluation result grade when evaluating the quality of laser inertial measurement unit. By mapping the numerical relationship between the designated reference level and the evaluation reference level of the index information under different distributions, the index evidence symmetrical with the evaluation reference level is given. After the uncertain input information is transformed into evidence of interval degree distribution by this method, the information fusion of interval degree distribution evidence is carried out by interval evidential reasoning algorithm, and the evaluation result is obtained by projection covariance matrix adaptive evolution strategy optimization. Taking a five-meter redundant laser inertial measurement unit as an example, the applicability and effectiveness of this method are verified.

Analysis of Software Reliability Growth Model with Gamma Family Distribution (감마족 분포를 이용한 소프트웨어 신뢰 성장 모형의 분석)

  • Kan, Kwang-Hyun;Jang, Byeong-Ok;Kim, Hee-Cheul
    • Journal of IKEEE
    • /
    • v.9 no.2 s.17
    • /
    • pp.143-151
    • /
    • 2005
  • Finite failure NHPP models proposed in the literature exhibit is either constant, monotonic increasing or monotonic decreasing failure occurrence rates per fault. For the sake of proposing shape parameter of the Gamma family distribution, used the special pattern. Data set, where the underlying failure process could not be adequately described by the knowing models, which motivated the development of the Gamma or Weibull model and Gompertz model. Analysis of failure data set that led us to the Gamma or Weibull model and Gompertz model using arithmetic and Laplace trend tests, bias tests was presented in this Paper.

  • PDF

Power Balancing Strategy in the Microgrid During Transient (마이크로그리드 과도상태 시 전력 수급 균형 전략)

  • Seo, Jae-Jin;Lee, Hak-Ju;Jung, Won-Wook;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

Nondestructive Evaluation by Joint Time-Frequency Analysis of Degraded SUS 316 Steel (열화된 SUS 316강의 시간-주파수 해석에 의한 비파괴평가)

  • Lee, Kun-Chan;Oh, Jeong-Hwan;Nam, Ki-Woo;Lee, Joo-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.4
    • /
    • pp.270-276
    • /
    • 1999
  • Fourier transform has been one of the most commonly used tools in study of frequency characteristics of signal. However, based on the Fourier transform. it is hard to tell whether a signal's frequency contents evolve in time or not. Recently, to overcome Fourier transform fault. not to represent non-stationary signal, time-frequency analysis methods are developed and those can represent informations of signal's time and frequency at the same time. In this study we analysed ultrasonic signal for degraded SUS 316 with time-frequency analysis method. In particular the methods such as short time Fourier(STFT) and Wigner-Ville distribution(WVD) were used to extract frequency contents and characteristics from ultrasonic signals.

  • PDF

Configuration of a Module for Monitoring Voltages Between Power Lines and Hull Onboard Vessels Based on the Vector Diagram at 3 Phase Ungrounded Power Distribution System (비접지 선박 3상 배전선로의 대지전압 벡터 모니터링 장치의 구성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1111-1116
    • /
    • 2011
  • Power distribution systems onboard vessels are typically configured without any live line connected to hulls for earthing purpose, where the line to hull voltages are affected and deformed depending on the impedances consisting of insulation resistances and distributed capacitances between power lines and hull. An insulation fault at power lines causes the line to hull voltages to increase to a higher level which brings more possibilities to electric shock and deterioration of insulation material. This study focuses on how to configure a module which enables to continuously monitor the voltages between power line and hull based on the vector diagram by analyzing the neutral point of 3 phase voltages and the algorithm for plotting method on the PC monitors.