• Title/Summary/Keyword: Distribution Channel System

Search Result 505, Processing Time 0.025 seconds

Verification of neutronics and thermal-hydraulic coupled system with pin-by-pin calculation for PWR core

  • Zhigang Li;Junjie Pan;Bangyang Xia;Shenglong Qiang;Wei Lu;Qing Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3213-3228
    • /
    • 2023
  • As an important part of the digital reactor, the pin-by-pin wise fine coupling calculation is a research hotspot in the field of nuclear engineering in recent years. It provides more precise and realistic simulation results for reactor design, operation and safety evaluation. CORCA-K a nodal code is redeveloped as a robust pin-by-pin wise neutronics and thermal-hydraulic coupled calculation code for pressurized water reactor (PWR) core. The nodal green's function method (NGFM) is used to solve the three-dimensional space-time neutron dynamics equation, and the single-phase single channel model and one-dimensional heat conduction model are used to solve the fluid field and fuel temperature field. The mesh scale of reactor core simulation is raised from the nodal-wise to the pin-wise. It is verified by two benchmarks: NEACRP 3D PWR and PWR MOX/UO2. The results show that: 1) the pin-by-pin wise coupling calculation system has good accuracy and can accurately simulate the key parameters in steady-state and transient coupling conditions, which is in good agreement with the reference results; 2) Compared with the nodal-wise coupling calculation, the pin-by-pin wise coupling calculation improves the fuel peak temperature, the range of power distribution is expanded, and the lower limit is reduced more.

Compressor Performance with Variation of Diffuser Vane Angle (디퓨저 베인각의 변화에 따른 압축기 성능 특성)

  • Shin, Y. H.;Kim, K. H.;Bae, M. H,;Kim, J. H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.2 s.7
    • /
    • pp.36-43
    • /
    • 2000
  • This study presents the centrifugal compressor performance for three different vane stagger angles and wall pressure distribution within vaned diffuser channels, and is also discussed about the stability with respect to the compressor components. As the vane stagger angle decreases, the flow rate for the stall onset decreases, and higher pressure can be obtained at the low flow rate region, however, the effective operation range of the compressor decreases because of the blockage effect of the diffuser vane. Low pressure pocket within the vaned diffuser channel moves from the pressure side of leading edge to the suction side as the flow rate decreases. The compressor system stability mainly depends on that of the diffuser.

  • PDF

Numerical Study of Laminar Flow over a Protruding Surface (I) - Flow Analysis - (돌출된 표면 위의 충류유동에 대한 전산 해석적 연구 (I) -유동 해석-)

  • Hwang, Jong-Yeon;Yang, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1418-1425
    • /
    • 1999
  • Flow over a protruding surface is investigated using numerical simulation. We consider flow between two parallel plates with a cube mounted on one side of the channel. As the flow approaches the cube, the adverse pressure gradient produces three-dimensional boundary-layer separation, resulting In the formation of horseshoe vortices. The objective of our study is to clarify both the steady and the unsteady characteristics of the vortex system. As the Reynolds number increases, the structure of the vortices near the cube becomes complex and the number of vortices increases. The distribution of skin friction on the cube-mounted wall reflects the effect of the horseshoe vortices. All these results are consistent with the experimental findings currently available.

A Study on the Cancellation of Harmonic Noise for the Improvement of Data Transmission Characteristics in Power Line Channel (전력선 채널의 데이터 전송 특성 개선을 위한 고조파 잡음 제거에 관한 연구)

  • 박준현;김남용;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.3
    • /
    • pp.259-269
    • /
    • 1991
  • In this paper, power line harmonic noise which is the most serious problem in the secondary power distribution line is eliminated and analyzed using adaptive noise cancellers with two adaptive algorithms, LMS and individual tap LMS(ITLMS) algorithm. To testify the improvement of data transmission characteristics made by the adaptive filter with two adaptive algorithms, BER was measured in DS spread spectrum communication system including the noise canceller.

  • PDF

New Cyclic Precoding Vectors for Open-loop Transmit Diversity Techniques

  • Lee, Kyoung-Jae;Lee, Heun-Chul;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.5A
    • /
    • pp.347-354
    • /
    • 2009
  • In this paper, we propose a new transmit diversity technique for multiple-input multiple-output (MIMO) systems to improve the link level performance of open-loop systems. By cyclically applying a predetermined set of preceding weight vectors, artificially induced fluctuation is created to achieve additional diversity gain in flat fading channels. To design the set of the precoding vectors, we exploit the knowledge on the distribution of near optimum Preceding vectors observed in a beamforming scheme based on the rotation transformations. Simulation results demonstrate that the proposed open-loop diversity scheme with an arbitrary number of transmit antennas achieves a full diversity gain with computational complexity comparable to a single-input single-output (SISO) system.

Effects of Rotation on the Czochralski Silicon Single Crystal Growth (초크랄스키법에 의한 실리콘 단결정성장에서 회전효과가 미치는 영향에 대한 연구)

  • 김무근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1308-1318
    • /
    • 1995
  • The influence of varying rotation speed of both crystal and crucible was numerically investigated for the Czochralski silicon-crystal growth. Based on a simplified model assuming flatness of free surfrae, the Navier-Stokes Boussinesq equations were employed to identify the flow pattern, temperature distribution as well as the shape of the melt/crystal interface. The present results showed that the interface shape was relatively convex with respect to the melt at lower pulling rate and tended to be concave as the pulling rate increased. In particular, the experimentally observed gull-winged shape of the interface was qualitatively in agreement with the predicted shape. The rotation of crystal alone little affected the growth system. When the rotation speed of the crucible was increased, there occurred inversion of the interface shape from convex to concave pattern. At rapid rotation of the crucible, an interesting channel formation was predictied primarily due to the assumption of laminar flow.

Fluid Flow and Temperature Distribution around a Surface-Mounted Module Cooled by Forced Air Flow in a Portable Personal Computers (휴대용 PC내에 실장된 강제공랭 모듈 주위의 유체유동과 온도분포)

  • Park S.H.;Shin D.J.;Lee I.T.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.729-732
    • /
    • 2002
  • This paper reports an experimental study around a module about forced air flow by blower($35{\times}35{\times}6mm^3$) in portable PC(10mm high, 200mm wide, and 235mm long). The channel inlet flow velocity has been varied between 0.26, 0.52 and 0.78m/s. The power input to the module is 4Wthis report, particular attention is directed to the fluid flow and adiabatic wall temperature($T_(ad)$) around a module which is under fluid mechanical and thermal influences of the module. The fluid flow around a module was visualized using PIV system. Liquid crystal thernography is used to determine the adiabatic wall temperature around a heated module on an acrylic board. Plots of $T_(ad)$ (or F) show marked effects of dispersion of thermal wake near the module.

  • PDF

Interoperable Middleware Gateway Based on HLA and DDS for L-V-C Simulation Training Systems (L-V-C 훈련체계 연동을 위한 HLA, DDS 기반의 연동 미들웨어 게이트웨이)

  • Jun, Hyung Kook;Eom, Young Ik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.6
    • /
    • pp.345-352
    • /
    • 2015
  • Recently, by developing many training systems in battle field, the demand for interconnecting and internetworking between Live, Virtual, Constructive training systems has been increased to support efficient data distribution and system control. But, there are lots of problems for them to interwork, because the existing researches only support L-L, V-V, C-C Interoperability. Therefore, we propose L-V-C gateway to provide interoperable simulation environment based on HLA and DDS between them. First, we illustrate FOM Management that parses RPR-FOM XML file to acquire Data information to be shared between them, and generates common data structure and source code used for L-V-C Gateway. L-V-C Gateway created from FOM Management supports Data Conversion and Quality of Service between HLA and DDS. HLA Federate and DDS Domainparticipant in L-V-C Gateway play a role of logical communication channel and relay data from HLA Federation to DDS Domain and vice versa.

Heat Transfer Analysis of a Pulse Magnetron Sputtering Cathode (펄스 마그네트론 스퍼터링 음극의 열전달 해석)

  • Joo, Jung-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.6
    • /
    • pp.274-278
    • /
    • 2008
  • 3-dimensional numerical analysis for a rectangular magnetron cathode model is done to predict cooling characteristics of high power sputtering system for ZnO deposition. It includes cooling channel design, heat transfer analysis of a target, bonding layer and backing plate. In order to model erosion profiles of a target, ion current density distribution from 3D Monte Carlo simulation is used to distribute total sputtering power to 5 discrete regions. At 3 kW of sputtering power and cooling water flow of 1 liter/min at $10^{\circ}C$, the maximum surface temperature was $45.8^{\circ}C$ for a flat new target and $156^{\circ}C$ for a target eroded by 1/3 of its thickness, respectively.

Heat and Flow Analysis of a Parallel Flow Heat Exchanger Using Porous Modeling (다공성 모델링을 이용한 평행류 열교환기의 열.유동 해석)

  • Jeong, Gil-Wan;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1784-1792
    • /
    • 2001
  • Numerical analysis on a parallel flow heat exchanger(PFHE) is performed using 2 dimensional turbulent porous modeling. This modeling can consider three-dimensional configuration of passage (flat tube with micro-channels), and the stability and accuracy of numerical results are improved. The geometrical parameters(e.g., the position of separators, inlet/outlet, and porosity of passages of a PFHE) are varied in order to examine the flow and thermal characteristics and flow distribution of the single phase multiple passages system. The flow non-uniformities along the paths of the PFHE are observed to evaluate the thermal performance of the heat exchanger. The location of inlet affects the heat transfer, and the location of outlet affects the pressure drop. The porosity with the optimum thermal performance is around 0.53.