• 제목/요약/키워드: Distributed mode

검색결과 562건 처리시간 0.03초

소규모 분산에너지시스템의 제어구조 및 운전 (마이크로터빈 중심) (Control and Operation of a Small Scale Distributed Energy System)

  • 홍원표;조재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1139_1141
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF

임의분포 사하중에 의한 정적처짐을 고려한 임의 변단면 보의 자유진동 (Free Vibrations of Arbitrary Tapered Beams with Static Deflections due to Arbitrary Distributed Dead Loads)

  • 이병구;오상진;이용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 춘계학술대회논문집; 전남대학교, 19 May 1995
    • /
    • pp.18-21
    • /
    • 1995
  • A numerical method is presented to obtain natural frequencies and mode shapes of the arbitrary tapered beams with static deflections due to arbitrary distributed dead loads. The differential equation governing the free vibration is derived and solved numerically. In the numerical example, the linearly tapered beams and both the triangular and sinusoidal distributed dead loads are chosen. The lowest three natural frequencies are reported and typical mode shapes are presented in the figure.

  • PDF

분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석 (Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System)

  • 김희중;배병열;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.

Quasi-Distributed Water Detection Sensor Based On a V-Grooved Single-Mode Optical Fiber Covered with Water-Soluble Index-Matched Medium

  • Kim, Dae Hyun;Kim, Kwang Taek
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.1-5
    • /
    • 2015
  • The V-grooved single-mode fiber in which a surface part of the core was removed was investigated as a quasi-distributed water detection sensor. In the normal state, the V-grooved region is filled and covered with a specific RI (Refractive Index)-matched medium, and the sensor experiences minimal optical loss. As water invades the V-grooved region, the material is dissolved and removed, and a considerable optical loss occurs owing to the large RI difference between the fiber core and water. The experimental results showed the feasibility of the device as a sensor element of the quasi-distributed water detection sensor system based on general optical time domain reflectometry (OTDR).

Performance Analysis of a Sliding Mode Control for Distributed Generations

  • Islam, Gazi;Al-Durra, Ahmed;Muyeen, S.M.;Caruna, Cedric;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.98-104
    • /
    • 2014
  • This paper presents the performance analysis of a sliding mode based hybrid controller for three phase voltage source inverter. The main objective of this analysis is to observe the effectiveness of the controller for fault ride through (FRT) capability improvement of the distributed generations (DG). The performance of the conventional PI based cascaded controller is also presented for comparison purpose.

분산전원 상세모델을 적용한 DC Micro-grid의 동작특성 분석 (Operational Characteristic Analysis of DC Micro-grid with Detail Model of Distributed Generation)

  • 이지헌;권기현;한병문;차한주
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2175-2184
    • /
    • 2009
  • This paper describes operational analysis results of the DC micro-grid using detailed model of distributed generation. Detailed model of wind power generation, photo-voltaic generation, fuel-cell generation was implemented with the user-defined model of PSCAD/EMTDC software that is coded with C-language. The operation analysis was carried out using PSCAD/EMTDC software, in which the power circuit is implemented by built-in model and the controller is modelled by user-defined model that is also coded with C-language. Various simulation results confirm that the DC micro-grid can operate without any problem in both the interconnected mode and the islanded mode. The operation analysis result confirms that the DC micro-grid make it feasible to provide power to the load stably. And it can be utilize to develop the actual system design and building.

1.6 Tb/s (160x10 Gb/s) WDM 신호의 단일 모드 광섬유 2,000 km 전송 (1.6 Tb/s (160x10 Gb/s) WDM Transmission over 2,000 km of Single Mode Fiber)

  • 한진수;장순혁;이현재
    • 한국통신학회논문지
    • /
    • 제29권7A호
    • /
    • pp.712-718
    • /
    • 2004
  • 분산형 라만 광증폭기와 어븀 첨가 광섬유 증폭기로 구성된 복합형 광증폭기를 사용하여 1.6 Tb/s (160${\times}$10 Gb/s) 전송 용량의 WDM 광신호를 단일 모드 광섬유 2,000 km에 전송한 결과에 대하여 기술한다. 복합형 광 증폭기를 사용하여 단일 모드 광섬유 2,000 km에 전송한 뒤의 평균 광 신호대 잡음비는 C/L-band에서 각각 20.5 dB, 21.9 dB 였고, 최저 Q-factor는 C/L-band에서 각각 14.65 dB(BER=5.8E-8), 13.75 dB(BER= 5.0E-7)였다. 이 결과에 Reed-Solomon (255, 239) Forward Error Correction(FEC) 코드 기능을 사용하여 무오류 전송 결과를 얻었다.

분포매개변수를 이용한 디스크 브레이크의 마찰기인 불안정성 해석 (Analysis of the Friction Induced Instability of Disc Brake using Distributed Parameter Model)

  • 차병규;조용구;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.601-606
    • /
    • 2004
  • This paper deals with friction-induced vibration of disc brake system under constant friction coefficient. A linear, lumped and distributed parameter model to represent the floating caliper disc brake system is proposed. The complex eigenvalues are used to investigate the dynamic stability and in order to verify simulations which are based on the theoretical model, the experimental modal test and the dynamometer test are performed. The comparison of experimental and theoretical results shows a good agreement and the analysis indicates that mode coupling due to friction force is responsible for disc brake squeal. And squeal type instability is investigated by using the parametric analysis. This indicates parameters which have influence on the propensity of brake squeal. This helped to validate the analysis model and establish confidence in the analysis results. Also they may be useful during system development or diagnostic analysis.

  • PDF

분포매개변수를 이용한 디스크 브레이크의 마찰기인 불안정성 해석 (Analysis of the Friction Induced Instability of Disc Brake Using Distributed Parameter Model)

  • 차병규;조용구;홍정혁;이유엽;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.702-708
    • /
    • 2004
  • This paper deals with friction-induced vibration of disc brake system under constant friction coefficient. A linear, lumped and distributed parameter model to represent the floating caliper disc brake system is proposed. The complex eigenvalues are used to investigate the dynamic stability and in order to verify simulations which are based on the theoretical model, the experimental modal test and the dynamometer test are performed. The comparison of experimental and theoretical results shows a good agreement and the analysis indicates that mode coupling due to friction force is responsible for disc brake squeal. And squeal type Instability is Investigated by using the parametric analysis. This indicates parameters which have influence on the propensity of brake squeal. This helped to validate the analysis model and establish confidence in the analysis results. Also they may be useful during system development or diagnostic analysis.

마이크로그리드에서 하이브리드 시스템의 Feeder Flow Mode 운영을 위한 제어 알고리즘 (Control Algorithm of Hybrid System for Feeder Flow Mode Operation in Microgrid)

  • 문대성;서재진;김윤성;원동준
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.1-7
    • /
    • 2011
  • Active power control scheme for distributed generation in microgrid consists of feeder flow control and unit power control. Feeder flow control is more useful than the unit power control for demand-side management, because microgrid can be treated as a dispatchable load at the point of common coupling(PCC). This paper presents detailed descriptions of the feeder flow control scheme for the hybrid system in microgrid. It is divided into three parts, namely, the setting of feeder flow reference range for stable hybrid system operation, feeder flow control algorithm depending on load change in microgrid and hysteresis control. Simulation results using the PSCAD/EMTDC are presented to validate the inverter control method for a feeder flow control mode. As a result, the feeder flow control algorithm for the hybrid system in microgrid is efficient for supplying continuously active power to customers without interruption.