• 제목/요약/키워드: Distributed mode

검색결과 562건 처리시간 0.023초

Improved Decoupled Control and Islanding Detection of Inverter-Based Distribution in Multibus Microgrid Systems

  • Pinto, Smitha Joyce;Panda, Gayadhar
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1526-1540
    • /
    • 2016
  • This work mainly discusses an accurate and fast islanding detection based on fractional wavelet packet transform (FRWPT)for multibus microgrid systems. The proposed protection scheme uses combined desirable features retrieved from discrete fractional Fourier transform (FRFT) and wavelet packet transform (WPT) techniques, which provides precise time-frequency information on minute perturbation signals introduced in the system. Moreover, this study focuses on the design of decoupling control with a distributed controller based on state feedback for the efficient operation of microgrid systems that are transitioning from the grid-connected mode to the islanded mode. An IEEE 9-bus test system with inverter based distributed generation (DG) units is considered for islanding assessment and smooth operation. Finally, tracking errors are greatly reduced with stability improvement based on the proposed controller. FRWPT based islanding detection is demonstrated via a time domain simulation of the system. Simulated results show an improvement in system stability with the application of the proposed controller and accurate islanding detection based on the FRWPT technique in comparison with the results obtained by applying the wavelet transform (WT) and WPT.

고정자의 유연성을 고려한 유체베어링 지지 HDD 스핀들 계의 진동해석 (Vibration Analyses of HDD Spindle Systems Supported by Hydrodynamic Bearings Taking into Account Stator's Flexibility)

  • 임승철;전상복;한윤식;이호성;김철순
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.749-756
    • /
    • 2005
  • This paper presents vibration analyses of hard disk drive (HDD) spindle systems based on the finite element method. The systems under investigation have a cantilevered shaft rotating on hydrodynamic bearings. In particular, the influence of stator's flexibility on major modes has been taken into account in dual ways lumped and distributed-parameter model approfches. Even the latter employs relatively macroscopic elements instead of extremely fine ones Popular in commercial codes. In order to prove the effectiveness of such formulated models, two types of HDD prototypes featuring different hub and stator structures are selected as examples. Compared to the first, the second type has a reinforced stator that would raise the natural frequency of the hub's translational (or sideway) mode. Both free and forced vibration characteristics are computed, and subsequently compared with the experimental data. It is our conclusion that Particularly the Proposed distributed model method is an efficient design tool for state-of-the-art HDD spindle systems.

SMF 길이와 RDPS가 랜덤하게 분포하는 분산 제어 광전송 링크에서 전체 잉여 분산 조절 위치에 따른 왜곡된 WDM 채널의 보상 (Compensation of the Distorted WDM Channels Depending on the Control Position of Net Residual Dispersion in Dispersion-managed Optical Link with the Randomly Distributed SMF Lengths and RDPS)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제21권2호
    • /
    • pp.187-192
    • /
    • 2017
  • 단일 모드 광섬유 (SMF; single mode fiber)의 길이와 중계 구간 당 잉여 분산 (RDPS; residual dispersion per span)이 랜덤하게 분포하는 광 위상 공액과 결합된 분산 제어 (DM; dispersion management)가 적용된 장거리 (50 fiber spans ${\times}80km$) 전송 링크에서 SMF와 분산 보상 광섬유 (DCF; dispersion compensating fiber) 배열과 전체 잉여 분산 (NRD; net residual dispersion)을 조절하는 위치에 따른 왜곡된 WDM 채널의 보상 특성을 수치적으로 분석해 보았다. NRD 조절 위치는 중계 구간을 구성하는 SMF와 DCF의 배열과 관계되어 있지만, NRD 조절의 구체적 위치보다 중계 구간을 이루는 SMF와 DCF의 배열이 WDM 채널의 수신 성능에 영향을 미치는 것을 확인하였다.

넓은 파장 가변영역을 가지는 반도체 레이저를 위한 Nonlinearly Chirped Grating의 설계 (Design of the nonlinearly chirped grating for broadly tunable semiconductor lasers)

  • 김덕봉;최안식;윤태훈;김재창;김선호
    • 한국광학회지
    • /
    • 제7권4호
    • /
    • pp.370-374
    • /
    • 1996
  • Superstructure Grating Distributed-Bragg Reflector(SSG DBR) 레이저는 비교적 높은 Mode Suppression Ratio(MSR)을 가지면서 넓은 파장 대에서 불연속 파장가변 특성을 가진다. 그러나 SSG DBR 레이저는 출력파장을 가변 시킬 때 파장가변 영역을 구성하는 채널 중 몇 개가 빠지는 현상이 실험을 통해 관찰되어 왔다. 우리는 수치해석적인 시뮬레이션을 통해 이 현상이 SSG DBR 거울을 구성하는 linearly chirped grating의 불균일한 반사 피크 높이에 의한 영향임을 발견했고 반사율 피크 높이를 거의 균일하게 만들 수 있는 nonlinearly chirped grating을 제안한다. 그리고 이 거울을 가지는 파장 가변 레이저가 채널의 손실 없이 넓은 파장가변 영역에서 동작하는 것을 확인했다. 그러므로 nonlinearly chirped grating을 가지는 DBR 거울은 넓은 파장가변 영역을 가지는 가변 레이저에 적용할 수 있다.

  • PDF

An Optimal Procedure for Sizing and Siting of DGs and Smart Meters in Active Distribution Networks Considering Loss Reduction

  • Sattarpour, T.;Nazarpour, D.;Golshannavaz, S.;Siano, P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.804-811
    • /
    • 2015
  • The presence of responsive loads in the promising active distribution networks (ADNs) would definitely affect the power system problems such as distributed generations (DGs) studies. Hence, an optimal procedure is proposed herein which takes into account the simultaneous placement of DGs and smart meters (SMs) in ADNs. SMs are taken into consideration for the sake of successful implementing of demand response programs (DRPs) such as direct load control (DLC) with end-side consumers. Seeking to power loss minimization, the optimization procedure is tackled with genetic algorithm (GA) and tested thoroughly on 69-bus distribution test system. Different scenarios including variations in the number of DG units, adaptive power factor (APF) mode for DGs to support reactive power, and individual or simultaneous placing of DGs and SMs have been established and interrogated in depth. The obtained results certify the considerable effect of DRPs and APF mode in determining the optimal size and site of DGs to be connected in ADN resulting to the lowest value of power losses as well.

직류 대체에너지 활용을 위한 Z-원 인버터 제어 (The Control of Z-Source Inverter for using DC Renewable Energy)

  • 박영산;배철오;남택근
    • 해양환경안전학회지
    • /
    • 제13권2호
    • /
    • pp.169-172
    • /
    • 2007
  • 본 논문은 Z-형 컨버터와 수정된 공간벡터 PWM인버터로 구성된 분산전원시스템의 회로모델과 제어 알고리즘을 보여주고 있다. Z-형 컨버터는 수동소자인 L과 C로 간단히 구성되어 있으며 인버터의 상하 양 소자가가 동시에 도통되도록 하는 구간을 이용해 승압을 함으로써 기존의 DC/DC 변환기와는 다른 형태를 취하고 있다. 점근 관측기를 이용한 이산시간 슬라이딩모드제어를 통해 전류제어를 함으로써 센서수를 줄이고 제어성능을 개선하였다. 대체에너지로 관심이 많은 태양광이나, 연료전지 그리고 소형 풍력발전으로부터 생산된 직류 에너지를 상용으로 사용할 수 있도록 하는 전력변환기로써 유용하게 사용될 수 있을 것이다.

  • PDF

광투과식 매연 측정법을 이용한 소형 디젤 차량의 무부하 급가속 조건에서의 매연 배출 특성 (Characteristics of Smoke Emissions from Light Duty Diesel Vehicles Using Light Extinction Smoke Measurement Method under free Acceleration Test Mode)

  • 강일호;이충훈
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.1-8
    • /
    • 2012
  • Characteristics of smoke emission in light duty diesel vehicles was investigated according to the year of production, engine displacement volume, and mileage. The smoke emission was measured using light extinction smoke measurement method under free acceleration test mode. Total number of the tested vehicles was 180. The year of production of the tested vehicles distributed from 2002 to 2007. The displacement volumes of the tested vehicles were categorized as 2-liter, 2.5-liter, 2.7-liter, and 3-liter. The mileage of the tested vehicles distributed from 20,000 km to 400,000 km. The more recent in the year of production of the tested vehicles did not show clearly lower in smoke emissions. Smoke emission showed different values according to driver's pedal pushing pattern. Also, smoke emission peak for each free acceleration test initially increased and reach a maximum of the peak values. Afterwards, the smoke peak gradually decreased as number of test increased. A new guide line was proposed to determine the smoke value from the light duty diesel vehicles based on smoke emission peak patterns which were obtained with several repeated free acceleration tests.

Utililty-Interfaced High-Frequency Flyback Transformer Linked Sinewave Pulse Modulated Inverter for a Small Scale Renewable Energy Conditioner

  • Chandhaket, Srawouth;Koninish, Yoshihiro;Nakaoka, Mutsou
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.112-123
    • /
    • 2002
  • This paper presents a novel prototype of the utility AC power interfaced soft-switching sinewave pulse modulated inverter using the high-frequency flyback for the small scale distributed renewable energy power conditioner. The proposed cricuit with a high-frequency isolation link has a funtion of electrical isolation, which is more cost-effective and reliable for the small-scale distributed renwal energy utilization system from a safety point of riew. The discontinuous conduction mode(DCM) operation of the high-frequency flyback transformer is adopted to establish a simple and low-cost circuit configuration and control scheme. For the simplicity, the circuit operating principle is described on the basis of the modified conventional full bridge inverter, whitch is the typical conventional high-frequency full-bridge inverter employing the high requency flyback transformer to eanble the effictive function of the electrical isolation. Than, the new circuit topology of the unility-interfaced soft-switching sinewave pulse modulated inverter using IGBTs is proposed. The proposed cricuit topology is additionally composed of the auxiliary power regenerating snubber cricuits, which are also mathematically analyzed for the parameter desigen settings. Finally, the performance of the propose inverter is evaluated on the basis of computer-aid simulation. It is noted that the sinewave pulse modulated output current of the inverter is synchronous to the AC main voltage.

마이크로터빈발전시스템 계통연계운전을 위한 동적 모델링 및 시뮬레이션 (Dynamic model and simulation of microturbine generation system for grid-connected operation)

  • 홍원표;조재훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.105-110
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of Power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF

Dispersion Management and Optical Phase Conjugation in Optical Transmission Links with a Randomly Distributed Single-Mode Fiber Length

  • Lee, Seong-Real
    • Journal of information and communication convergence engineering
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Suppressing or mitigating signal distortion due to group velocity dispersion and optical Kerr effects is necessary in ultra-high speed and long-haul wavelength division multiplexing (WDM) transmission systems. Dispersion management (DM), optical phase conjugation (OPC), and the combination of these two are promising techniques to compensate for signal distortion. In this paper, to implement a flexible optical WDM network, a new optical link configuration with a randomly distributed single-mode fiber (SMF) length and fixed residual dispersion per span in the combination of DM and OPC is proposed and investigated. The simulation results show that the best net residual dispersion (NRD) in the proposed optical links is +10 ps/nm, which is independent of pre- and postcompensation. The effective launch power of the WDM channel is increased more in the optical links with NRD = +10 ps/nm controlled by only precompensation. Furthermore, the system performance difference between the proposed optical link configuration with the best NRD and the conventional optical link with uniform distribution of the SMF length had little significance. Consequently, it is confirmed that the proposed optical link configuration with the best NRD is effective and useful for implementing a reconfigurable long-haul WDM network.