• Title/Summary/Keyword: Distributed generations

Search Result 134, Processing Time 0.03 seconds

The Effect of Sub-division (Two or Three Sub-populations) of a Population on Genetic Gain and Genetic Diversity

  • Oikawa, T.;Matsui, H.;Sato, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.6
    • /
    • pp.767-771
    • /
    • 2002
  • Breeding efficiencies were compared among three population schemes: a single population, a population with two subpopulations and a population with three sub-populations. A simulation experiment of selection was carried out for 10 generations with 20 replications each by comparing average breeding values and inbreeding coefficients among the three population schemes. Phenotypes of three traits were generated with a model comprising 36 loci, each with additive genetic effects and residuals distributed normally. Among the three population schemes, the single population scheme was definitely superior to the other two with regards to selection response and inbreeding. The multiple sub-population scheme was, however, considered to be an alternative population scheme when the difference in economic weights of the traits was small among the sub-populations, assuming moderate inbreeding depression for traits and crossbreeding. The scheme with two sub-populations had a higher genetic value than that with three subpopulations; however, the genetic values of the schemes were comparable when maternal heterosis was taken into account. The choice of population schemes may depend on the cost-sharing policy between the breeding population and the commercial population rather than just the breeding efficiency.

An Emission-Aware Day-Ahead Power Scheduling System for Internet of Energy

  • Huang, Chenn-Jung;Hu, Kai-Wen;Liu, An-Feng;Chen, Liang-Chun;Chen, Chih-Ting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.10
    • /
    • pp.4988-5012
    • /
    • 2019
  • As a subset of the Internet of Things, the Internet of Energy (IoE) is expected to tackle the problems faced by the current smart grid framework. Notably, the conventional day-ahead power scheduling of the smart grid should be redesigned in the IoE architecture to take into consideration the intermittence of scattered renewable generations, large amounts of power consumption data, and the uncertainty of the arrival time of electric vehicles (EVs). Accordingly, a day-ahead power scheduling system for the future IoE is proposed in this research to maximize the usage of distributed renewables and reduce carbon emission caused by the traditional power generation. Meanwhile, flexible charging mechanism of EVs is employed to provide preferred charging options for moving EVs and flatten the load profile simultaneously. The simulation results revealed that the proposed power scheduling mechanism not only achieves emission reduction and balances power load and supply effectively, but also fits each individual EV user's preference.

Effectiveness of E-Training, E-Leadership, and Work Life Balance on Employee Performance during COVID-19

  • WOLOR, Christian Wiradendi;SOLIKHAH, Solikhah;FIDHYALLAH, Nadya Fadillah;LESTARI, Deniar Puji
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.443-450
    • /
    • 2020
  • This study aims to add insight into the effectiveness of e-training, e-leadership, work-life balance, and work motivation on millennial generation employees' performance in today's work life amid the outbreak of the COVID-19 pandemic that requires to work more online. Unlike previous generations, millennials are technology-literate, intent on succeeding quickly, give up easily, and seek instantaneous gratification. The population in this study are millennial generation employees at one of Honda motorcycle dealers in Jakarta, Indonesia. The number of samples collected was 200. The sampling technique used is the side probability method, with proportional random sampling technique. The research method used is an associative quantitative approach through survey methods and Structural Equation Modeling. Data were collected through questionnaires distributed to millennial generation employees, with results then processed through the Lisrel 8.5 program. The results of this study show, first, that e-training, e-leadership, and work-life balance have positive effect on work motivation. Second, e-training, e-leadership, work-life balance, and work motivation have positive effect on employees' performance. The findings indicate that companies must pay attention to the factors of e-training, e-leadership, and work-life balance to keep employees motivated and to maintain optimal employee performance, especially during the COVID-19 pandemic through working online.

A Study on Changes in Cost of Housing at Marriage by Age Group in Terms of Inter-generational Transfers (세대간 자산이전측면에서 연령대에 따른 결혼시 주거자금 마련 변화추이)

  • Lee, So-Young
    • Journal of Families and Better Life
    • /
    • v.29 no.4
    • /
    • pp.205-216
    • /
    • 2011
  • Unequal distribution of shares among children during intergenerational transference of assets has been prevalent in Korea. This study intends to examine whether parental contribution, in the form of a cash gift, is differentiated between the bride's side and the bridegroom's side at marriage and by age group. This pattern may also change according to the generation. Questionnaires were equally distributed to members of three previously delineated age groups: 20' s-30' s, 40's -50's, and 60's and above who are married or have been married at least once and reside in Seoul or Gyeonggi province. A total of 700 questionnaires were analyzed using SPSS and the data were sorted by age group. The results indicate an apparent difference between the husband's side and the wife's side in providing funding for housing at marriage in that a large portion of the funding is provided by the husband's side. Among various funding sources, a cash gift from the couple's parents appears to fund the largest portion of the total cost for housing and marriage. Results show that a cash gift from the couple's parents funds a larger portion of housing expenses for younger generations, a phenomenon that becomes more severe and apparent the younger the couple is.

Visitor perception survey on the Saemangeum reclamation district (새만금 사업 지구의 방문객 인식 조사)

  • Son, Jae-Gwon;Kim, Seong-Su;Choi, Jin-Kyu;Jang, Dong-Heon
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.4
    • /
    • pp.595-602
    • /
    • 2012
  • Main objective is to examine visitors the image, awareness of Saemangeum to examine its image, awareness, expected projects, and areas of improvement. This can establish measures for publicity and nation-wide participation. Main results are as following. First, visitors are broadly distributed to all age groups. Majority of visiting is travel and rate of returning visit is high as well. Second, the Saemangeum project is positively recognized and it is expected to be a prime development of the west coast in the future. Third, TV has significantly contributed to the visit to Saemangeum but the internet has larger effects in younger generations. Furthermore, rest and experience facilities, accommodations, and food items are major areas of improvement. Fourth, visitors have high expectations for tours, leisure, and ecosystems. Therefore, efforts should be made to become the Mecca of greed-development and cultural tourism. Fifth, many people replied that Saemangeum is an assistance to the national development but water quality management should be continued. In addition, the public participation should be made centrically cultural and economical participations.

Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections (병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석)

  • Jung, Young-Seok;Yu, Byung-Gyu;Kang, Gi-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

Performance Analysis and Evaluation of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 평가분석)

  • So, Jung-Hun;Jung, Young-Seok;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.509-516
    • /
    • 2004
  • The concerns of distributed generations including photovoltaic(PV) system have been increased around the world since PV system is becoming widespread as a clean and gentle energy source for earth. In the future high density grid-connected PV systems will be interconnected with distribution network. As a result, the stability and long-term reliability of PV systems have become more important issues in this area. Grid-connected PV systems have been installed and monitored at field demonstration test center(FDTC) and also data acquisition system(DAS) has been constructed for measuring and analyzing performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV system has been evaluated and analyzed for component perspective (PV array and power conditioning system) and global perspective (system efficiency, capacity factor, and electrical power energy) by field test and loss factors of PV system.

A Study on the Effective Downscaling Methodology for Design of a Micro Smart Grid Simulator

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1425-1437
    • /
    • 2018
  • In this paper, a methodology was proposed to reduce the electrical level and spatial size of the smart grid with distributed generations (DGs) to a scale in which the electrical phenomena and control strategies for disturbances on the smart grid could be safely and freely experimented and observed. Based on the design methodology, a micro smart grid simulator with a substation transformer capacity of 190VA, voltage level of 19V, maximum breaking current of 20A and size of $2{\times}2m^2$ was designed by reducing the substation transformer capacity of 45MVA, voltage level of 23kV and area of $2{\times}2km^2$ of the smart grid to over one thousandth, and also reducing the maximum breaking current of 12kA of the smart grid to 1/600. It was verified that the proposed design methodology and designed micro smart grid simulator were very effective by identifying how all of the fault currents are limited to within the maximum breaking current of 20A, and by confirming that the maximum error between the fault currents obtained from the fault analysis method and the simulation method is within 1.8% through the EMTP-RV simulation results to the micro smart grid simulator model.

Modification of an Analysis Algorithm for DC Power Systems Considering Scalable Topologies

  • Lee, Won-Poong;Choi, Jin-Young;Park, Young-Ho;Kim, Soo-Nam;Won, Dong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1852-1863
    • /
    • 2018
  • Direct current(DC) systems have recently attracted attention due to the increase in DC loads and distributed generations, such as renewable energy sources. Among these technologies, there has been much research into DC distribution systems or DC microgrids. Within this body of research, the main topics have been about optimum control and operation methods in terms of improving power efficiency. When DC systems are controlled and operated using power electronic devices such as converters, it is necessary to design and analyze them by considering the power electronics sections. For this reason, we propose a scalable DC system analysis algorithm, which considers various system configurations depending on the operating mode and location of the converter. The algorithm consists of power flow fault current calculations, and the results of the algorithm can be used for designing DC systems. The algorithm is implemented using MATLAB with defined input and output data. The verification of the algorithm is mainly performed using ETAP software, and the accuracy of the algorithm analysis can be confirmed through the results.

Study on Improvement of Overcurernt Relay (OCR)'s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation (분산전원이 도입된 배전계통에 초전도한류기 적용에 따른 과전류계전기 동작향상 연구)

  • Lim, Seung-Taek;Lim, Sung-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.300-304
    • /
    • 2017
  • Due to the introduction of various types of dispersed generations (DGs) with larger capacity in a power distribution system, the short-circuit current is expected to be increased, which more requires for the effective fault current limiting methods. As one of the promising countermeasures, the superconducting fault current limiter (SFCL) has been noticed. However, the decreased fault current by SFCL affects the operation of the overcurrent relay (OCR), representative protective device in a power distribution system. In this paper, the operation of the overcurrent relay due to the application of a SFCL in a power distribution system with DG linked by its bus line was analysed through the short-circuit tests. To analyze the effect of the SFCL application in a power distribution system with DG, the experimental simulated circuits were designed and the short-circuit tests for the power distributed system assembled with the DG, the OCR and the SFCL were carried out. Through the analysis on the short-circuit tests, the application of the SFCL in a power distribution system with DG could be confirmed to be contributed to the operational improvement of overcurrent relay.