• 제목/요약/키워드: Distortion free

검색결과 175건 처리시간 0.03초

박판 패널 자유 단의 용접 좌굴 변형 방지에 관한 연구 (Prevention of Welding-induced Free Edge Buckling Distortion in Thin-plated Panels)

  • 한명수;김현욱
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.20-22
    • /
    • 2007
  • Welding-induced buckling distortion at the free edge of thin-plated panels has been studied. Welding distortion at free edges causes the additional man hours to straighten for the easy adjusting works of the following assembly stage. Therefore, it is necessary to develop a free-edge distortion control method. It is the purpose in the study to evaluate the effectiveness of buckling distortion prevention of the current design practice and design modification.

  • PDF

Theoretical and practical features of J-scaled distortion-free HSQC

  • Cha, Jin Wook;Park, Sunghyouk
    • 한국자기공명학회논문지
    • /
    • 제25권1호
    • /
    • pp.1-7
    • /
    • 2021
  • Employing of 13C stable-isotopes in NMR metabolomics can give unique splitting patterns and coupling constants information originated from 13C-13C coupling interaction that provide an important structural information regarding the cellular metabolic process. But it has been known that an undesirable signal distortion in 2D heteronuclear correlation study, due to 13C-13C interaction, hampers an analysis of the coupling information. Recently, we proposed J-scaled distortion-free heteronuclear single-quantum coherence (HSQC) sequence which provides a distortion-free 13C-13C coupling information with a selective resolution enhancement of JCC splitting. In this paper, we dicuss theoretical aspect and practical feature of J-scaled HSQC pulse sequence. The conceptual explanation of orgin of the signal distortion by 13C-13C coupling interaction and design of J-scaled HSQC through exemplified results are provided in brief.

자기공명영상을 이용한 근육 단면적 측정법의 활용을 위한 영상왜곡보정 (Distortion Correction in Magnetic Resonance Images on the Measurement of Muscle Cross-sectional Area)

  • 홍철표;이동훈;박지원;한봉수
    • The Journal of Korean Physical Therapy
    • /
    • 제24권2호
    • /
    • pp.66-72
    • /
    • 2012
  • Purpose: The purpose of this study is to explore the importance of the image distortion correction in the cross sectional area measurement for the iliopsas muscle, tensor fasciae latae muscle, gluteus maximus muscle and the knee extensor muscles, by using (magnetic resonance imaging) MRI. Methods: This study was performed using an open 0.32T MRI system. To estimate the image distortion, T1 images for an AAPM homogeneity/linearity phantom were acquired, and the region in which the maximum geometric distortion was less than or equal to the pixel size (1.6 mm) of the images, it was defined as the distortion correction-free region. The T2 images for a human subject's pelvis and thigh in normal positions were obtained. Then, after the regions of interest in the pelvis and thigh were moved into the distortion correction-free region, T2 images for the pelvis and thigh were scanned with the same imaging parameters used in the previous T2 imaging. The cross-sectional areas were measured in the two T2 images that were obtained in the normal position, and the distortion correction-free region, as well as the area error caused by geometric image distortion was calculated. Results: The geometrical distortion is gradually increased, from the magnet center to the outer region, in axial and coronal plane. The cross-sectional area error of gluteus maximus muscle and the knee extensors was as high as 9.27% and 3.16% in before and after distortion correction, respectively. Conclusion: The cross-sectional area of the muscles that suffered from the geometrical distortion is necessary to correct for the estimation of the intervention.

Experimental Study of Large-amplitude Wavefront Correction in Free-space Coherent Optical Communication

  • Guo, Qian;Cheng, Shuang;Ke, Xizheng
    • Current Optics and Photonics
    • /
    • 제5권6호
    • /
    • pp.627-640
    • /
    • 2021
  • In a free-space coherent optical communication system, wavefront distortion is frequently beyond the correction range of the adaptive-optics system after the laser has propagated through the atmospheric turbulence. A method of residual wavefront correction is proposed, to improve the quality of coherent optical communication in free space. The relationship between the wavefront phase expanded by Zernike polynomials and the mixing efficiency is derived analytically. The influence of Zernike-polynomial distortion on the bit-error rate (BER) of a phase-modulation system is analyzed. From the theoretical analysis, the BER of the system changes periodically, due to the periodic extension of wavefront distortion. Experimental results show that the BER after correction is reduced from 10-1 to 10-4; however, when the closed-loop control algorithm with residual correction is used, the experimental results show that the BER is reduced from 10-1 to 10-7.

맞대기 용접시의 각변형 거동에 관한 연구 (Behavior of angular distortion in butt joint welding of thin plate structure)

  • 배강열;김희진
    • Journal of Welding and Joining
    • /
    • 제6권3호
    • /
    • pp.21-26
    • /
    • 1988
  • The behavior of angular distortion in butt joint wleding of thin plate structure is investigated with an experimental model and partially with a computational model. The experimental model studying the effects of specimene size and degree of restraint on the angular distorion offers a good method for analyzing the behavior of the distrotion. In addition, the distrotion during welding was demonstrated by both experimental measurement and numericla prediciton. The facts evealed in this study are as follows : 1) distrotion angles were changed with variations of specimene wldth. 2) With the restraint, angular distrotion was reduced to 20% to that of free joint. 3) After the restraint being removed, the effect of restraint was also remained. 4) Same heat input per unit thickness caused same amount of distortion. 5) The mode of angular distortion was expected to be changed with expected to be changed with time, i.e. convex movement during heating and concave one during cooling.

  • PDF

왜곡 제거 시계열 매칭의 시각화 도구 (Visualization Tool of Distortion-Free Time-Series Matching)

  • 문성우;이상훈;김범수;문양세
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제4권9호
    • /
    • pp.377-384
    • /
    • 2015
  • 본 논문에서는 왜곡 제거 시계열 매칭의 시각화 도구를 제안한다. 시계열 매칭에서 왜곡 제거 지원은 정확한 유사 시계열 검색을 위한 매우 중요한 요소이다. 본 논문에서는 시계열에서 발생하는 잡음, 위치 이동, 진폭 조정, 선형 추세의 왜곡들을 이동평균 변환, 정규화 변환, 선형 추세 제거 기법을 사용하여 제거한 후, 시계열 매칭을 수행하고 그 결과를 시각화한다. 본 논문에서 제안하는 시각화 도구는 클라이언트-서버 모델을 기반으로 구현된다. 클라이언트는 사용자가 선택한 시계열의 왜곡을 제거하여 서버에 전달하고, 매칭 결과의 시각화를 수행한다. 서버는 R*-트리 기반의 다차원 인덱스로 왜곡 제거 시계열 매칭을 효율적으로 수행한다. 왜곡 제거 시계열 매칭의 결과는 다섯 가지 차트로 달리 표현하여 사용자가 직관적이고 쉽게 이해할 수 있도록 구현한다.

MZ변조기를 이용한 ROF링크에서 OFDM신호의 비선형왜곡 효과 (Nonlinear Distortion Effects of OFDM Signals in a Radio over fiber Link Involving in a Mach-Zehnder Modulator)

  • ;송주빈
    • 한국통신학회논문지
    • /
    • 제31권10A호
    • /
    • pp.935-942
    • /
    • 2006
  • Radio over Fiber(ROF) 채널에서의 비선형효과는 시스템의 성능을 감소하는 주요 원인 중에 하나이다. 특히, 휴대인터넷 및 고속무선통신에서 Orthogonal Frequency Division Multiplex(OFDM) 방식이 주로 사용되는데 이 신호가 ROF 링크를 통하여 전송될 때 전체 시스템의 성능을 충족하여야 한다. 본 논문에서는 Mach-Zehnder(MZ) 변조기를 사용한 5.8GHz의 OFDM 신호기반 RoF 링크의 비선형효과를 해석하였다. OFDM-RoF 시스템의 평균자승오차 성능을 구하였다. 변조 왜곡된 후 RoF 링크에서 단일 캐리어에 대한 평균자승오차 성능과 SNR이 20dB로 고정된 경우 왜곡이 없는 OFDM신호를 사용한 경우의 평균자승오차 성능을 비교 검증하였다. OFDM-RoF 링크를 선형화하기 위하여 offset 바이어스 등 pre-distortion기술을 사용하였다. Pre-distortion기술에 따른 distortion-free dynamic range 및 SNR의 성능결과를 비교하였다.

Dynamic Range Improvement of IM-DD Optical Link using Dual-Wavelength Dual-Parallel Modulation

  • Li, Xianghua;Yang, Chun;Zhou, Zhenghua;Chong, Yuhua
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.330-334
    • /
    • 2014
  • In this paper, we present an incoherent dual-parallel modulation linearized optical link employing two different optical wavelengths. Comparing with previous dual-parallel modulation, this linearization method prevents the recreation of distortion products and can be readily implemented. Furthermore, a dual-wavelength dual-parallel modulation linearized optical link constructed with the commercially available devices is experimentally demonstrated with a spurious-free dynamic range of $122.5dB.Hz^{4/5}$. More than 25 dB suppression of the intermodulation distortion, 15.6 dB improvement of spurious-free dynamic range and 1.5 dB improvement of compression dynamic range are achieved after linearization.

Distortion Control of the Curved Panel Using Elastic Bending Method

  • Kim H. G.;Shin S. B.;Youn J. G.
    • International Journal of Korean Welding Society
    • /
    • 제5권1호
    • /
    • pp.29-34
    • /
    • 2005
  • Finite element analysis (FEA) and experimental studies on an elastic bending method have been performed in order to control the angular distortion at the fillet weldment for curved panel. Process parameters for the elastic bending method such as clamping span and release time were analyzed with reference to welding condition and geometric effect of the curved panel, which can minimize or prevent the angular distortion by producing a proper skin stress to the fillet weldment. The amounts of the angular distortion decrease almost in a linear manner with an increase in the skin stress. The skin stress required for non-angular distortion at the fillet weldment is strongly dependent on the plate thickness, not the heat intensity applied. The clamping span for obtaining uniform skin stress was defined as functions of the plate thickness and length of the free edge. Clamp should be removed after the fillet weldment is cooled down to room temperature for non-angular distortion. Effectiveness of the elastic bending method established was verified by its application to an actual curved panel.

  • PDF

Multi-bit Sigma-Delta Modulator for Low Distortion and High-Speed Operation

  • Kim, Yi-Gyeong;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • 제29권6호
    • /
    • pp.835-837
    • /
    • 2007
  • A multi-bit sigma-delta modulator architecture is described for low-distortion performance and a high-speed operation. The proposed architecture uses both a delayed code and a delayed differential code of analog-to-digital converter in the feedback path, thereby suppressing signal components in the integrators and relaxing the timing requirement of the analog-to-digital converter and the scrambler logic. Implemented by a 0.13 ${\mu}m$ CMOS process, the sigma-delta modulator achieves high linearity. The measured spurious-free dynamic range is 89.1 dB for -6 dBFS input signal.

  • PDF