• Title/Summary/Keyword: Distance errors

Search Result 683, Processing Time 0.031 seconds

Determining the Location of Metallic Needle from MR Images Distorted by Susceptibility Difference (자화율 차이로 인해 왜곡된 영상으로부터 금속 바늘의 위치 결정)

  • Kim, Eun-Ju;Kim, Dae-Hong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.87-94
    • /
    • 2010
  • Purpose : To calculate the appearance of the image distortion from metallic artifacts and to determine the location of a metallic needle from a distorted MR image. Materials and Methods : To examine metal artifacts, an infinite metal cylinder in a strong magnetic field are assumed. The cylinder’s axis leaned toward the magnetic field along some arbitrary angle. The Laplace equation for this situation was solved to investigate the magnetic field distortion, and the simulation was performed to evaluation the image artifact caused by both readout and slice-selection gradient field. Using the result of the calculation, the exact locations of the metal cylinder were calculated from acquired images. Results : The distances between the center and the folded point are measured from images and calculated. Percentage errors between the measured and calculated distance were less than 5%, except for one case. Conclusion : The simulation was successfully performed when the metal cylinder was skewed at an arbitrary tilted angle relative to the main magnetic field. This method will make it possible to monitor and guide both biopsy and surgery with real time MRI.

Numerical Analysis of Flowfield around Multicopter for the Analysis of Air Data Sensor Installation (대기자료센서 장착위치 분석을 위한 멀티콥터 주변 유동장 수치해석)

  • Park, Young Min;Lee, Chang Ho;Lee, Yung Gyo
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.20-27
    • /
    • 2017
  • The present paper describes the flow analysis of the flows around the multicopter for the selection of optimal position of air data sensor. For the flow analysis, the commercial fluid dynamics solver, STAR-CCM+ was used with polygon mesh and k-w SST turbulence modeling options. For the simulation of each rotating 4 propellers, unstructured overset mesh method was used. Hovering, forward flight, ascending and descending flight conditions are selected for the analysis and airspeed and flow angle errors were investigated using the CFD results. Through the flow field analysis, sensor location above one propeller diameter distance from the propeller rotating plane showed airspeed error less than 1m/s within the typical flight conditions of multicopter except descending.

An Enhanced Genetic Algorithm for Reader Anti-collision in RFID System (RFID 시스템에서의 리더 충돌 방지를 위한 개선된 유전자 알고리즘)

  • Seo, Hyun-Sik;Lee, Chae-Woo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.5
    • /
    • pp.85-94
    • /
    • 2008
  • When an RFID reader uses the same frequency or adjacent frequency with neighbor readers, the interference might occur. These interferences cause the RFID reader collision and errors during tag recognition. Therefore, the international standard for RFID and some papers proposed the methods to reduce the reader collision. The reader interference is closely related to the distance between the readers haying interference and used frequency band. In the previous RFID reader anti-collision algorithms, the location of readers inducing interference which is closely related to interference of readers is not considered. Only the reader collision is tried to reduce through frequency transfer after collisions occur or modification of frame size in relation to collision probability based a TDM(Time Division Multiplex). In this paper, the genetic algorithm using two-dimensional chromosome which reflect readers' location is proposed to prevent reader collision effectively. By executing evolutionary operation with two-dimensional chromosome, the location information having influence on reader interference can be used. The repair operation in the proposed algorithm makes all reader stably recognize their tags.

The Influence of Noise Environment upon Voice and Data Transmission in the RF-CBTC System

  • Kim, Min-Seok;Lee, Sang-Hyeok;Lee, Jong-Woo
    • International Journal of Railway
    • /
    • v.3 no.2
    • /
    • pp.39-45
    • /
    • 2010
  • The RF-CBTC (Radio Frequency-Communication Based Train Control) System is a communication system in railroad systems. The communication method of RF-CBTC system is the wireless between the wayside device and on-board device. The wayside device collects its location and speed from each train and transmits the distance from the forwarding train to the speed-limit position to it. The on-board device controlling device controls the speed optimum for the train. In the case of the RF-CBTC system used in Korea, transmission frequency is 2.4 [GHz]. It is the range of ISM(Industrial Scientific and Medical equipment) band and transmission of voice and data is performed by CDMA (Code Division Multiple Access) method. So noises are made in the AWGN (Additive White Gaussian Noise) and fading environment. Currently, the SNR (Signal to Noise Ratio) is about 20 [dB], so due to bit errors made by noises, transmission of reliable information to the train is not easy. Also, in the case that two tracks are put to a single direction, it is needed that two trains transmit reliable voice and data to a wayside device. But, by noises, it is not easy that just a train transmits reliable information. In this paper, we estimated the BER (Bit Error Rate) related to the SNR of voice and data transmission in the environment such as AWGN and fading from the RF-CBTC system using the CDMA method. Also, we supposed the SNR which is required to meet the BER standard for voice and data transmission. By increasing the processing gain that is a ratio of chip transmission to voice and data transmission, we made possible voice and data transmission from maximally two trains to a wayside device, and demonstrated it by using Matlab program.

  • PDF

A Study on the Robustness of a 16Kbps SBC over the Rayleigh fading Channel Error (16Kbps SBC의 Rayleigh 페이딩 채널에러에 대한 강인성 연구)

  • 오수환;이상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.4
    • /
    • pp.287-295
    • /
    • 1986
  • In this paper, a SBC(sub-band-coding) is proposed to code a speech signal for a digital mobile radio and a robustness of speech quality of the SBC over the Rayleigh fading channel is investigated via a computer simulation. First the Rayleigh fading channel and 16-ary DPSK receiver models are presentes and verified its validitties by comparing with theoretical values. Three different measures: SNR, LPC distance measure and subjective listening test, were used to evaluate the effects due to the Rayleigh fading channel errors. From the results of computer simulation at BER=$10_{-3}$, $10_{-2}$, 5$ imes$$10_{-2}$, it was found that the speech remained quite intelligible at BER=$10_{-2}$and the link is still usuable even at BER=5$ imes$$10_{-2}$ Thus it was concluded that the SBC can be applicable to the digital mobile radio on the Rayleigh fading channel error in the range of $10_{-4}$~$10_{-2}$ without emplowing any error correction codes.

  • PDF

Development of Wireless Respiratory Air Flow and Urinary Flow Measurement System for Home Healthcare (가정용 무선 호흡기류 및 요속신호 계측 시스템 개발)

  • Cha, Eun-Jong;Lee, In-Kwang;Lee, You-Mi;Han, Soon-Wha;Han, Jeong-Su;Suh, Jae-Won;Park, Chan-Sik;Kim, Kyung-Ah
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1350-1357
    • /
    • 2012
  • Medical system for personal health management recently changes its paradigm from hospital service to self home care based on ubiquitous technology for healthcare anywhere at any time. The present study developed a wireless bio-signal measurement system for patients to self manage pulmonary disease and benign prostate hyperplasia(BPH), both of which are chronic diseases with increasing frequency in modern society. Velocity-type respiratory air flow transducer adapted to develop respiratory module for pulmonary disease management was simplified in structure to measure uni-directional flow since most important diagnostic parameters are evaluated on the expiratory flow signal only. Standard weight measurement technique was introduced to obtain urinary flow signal for BPH management. Three load cell signals were acquired for averaging to minimize noise, followed by accuracy evaluation. Transmission and receiver modules were also developed with user program for wireless communication. Averaged relative errors were 2.05 and 1.02% for respiratory volume and maximal flow rate, respectively, and the relative error was 2.17% for urinary volume, demonstrating that both modules enabled very accurate measurements. Wireless communication distance was verified within 15m, long enough for home care application. The present system allows the user to select a necessary measurement module on a particular health demand and to immediately provide the self-test results, thus better quality health care would be possible.

Performance Evaluation of the M-algorithm for Decoding Convolutional Codes (M-알고리듬을 이용한 컨벌루셔널 부호의 복호 성능 평가)

  • 천진영;최규호;성원진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3A
    • /
    • pp.188-195
    • /
    • 2002
  • The M-algorithm for decoding convolutional codes can significantly reduce the complexity of the Viterbi algorithm by tracking a fixed number of survivor paths in each level of the decoding trellis. It is an easily-implementable algorithm suited for real-time processing of high-speed data. The algorithm, however, generates a sequence of catastrophic errors when the correct path is not included in the set of survivor paths. In this paper, the performance of the M-algorithm obtained from using various decoding complexity levels, frame lengths, and code constraint lengths is presented. The performance gain is quantified when the algorithm is used in conjunction with codes of increased constraint length. In particular, it is demonstrated the gain from the increased code free distance overcompensates the loss from the correct path being excluded from the survivors, when the frame length is short to moderate. Using 64 survivor paths, the signal-to-noise ratio gain obtained by increasing the constraint length from K=7 to K=9, 11, 15 is respectively 0.6, 0.75, and 08dB, when the frame of length L=100 has the frame error rate of 0.01%.

A study on the derivation of Dimensionless Unit Hydrographs by the Linear model in the small watersheds (선형 Model에 의한 소류역에 있어서의 무차원 단위도 유도에 관한 연구)

  • 이순혁;한중석
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.23 no.3
    • /
    • pp.78-87
    • /
    • 1981
  • This study was attempted to get dimensionless unit hydrograph by linear model which can be used to the estimation of flood for the development of Agricultural water resources and laid emphasis on the application of dimensionless unit hydrographs for the ungaged watersheds by applying linear model. The results summarized through this study are as follows. 1.Peak discharge is found to be Qp= CAR (C =0. 895A-o.145) having high significance between peak discharge, Qp and effective rainfall, R within the range of small watershed area, 84 to 470km2. consequently, linearity was acknowledged between rainfall and runoff. Reasonability is confirmed for the derivation of dimensionless unit hydrograph by linear model. 2.Through mathematical analysis, formula for the derivation of dimensionless unit hydrograph was derived. qp--p=(tp--t)n-1[e-(n-1)](tp--t-1) 3.Moment method was used for the evaluation of storage constant, K and shape parameter, n for the derivation of dimensionless unit hydrograph. Storage constant, K is more closely related with the such watershed characteristics as length of main stream and slopes. On the other hand, the shape parameter, n was derived with such watershed characteristics as watershed area, river length, centroid distance of the basin and slopes. 4.Time to peak discharge, Tp could be expressed as Tp=1. 25 (√s/L)0.76 having a high significance. 5.Dimensionless unit hydrographs by linear model stood more closely to the observe dimensionless unit hydrographs On the contrary, dimensionless unit hydrographs by S.C. S. method has much difference in comparison with linear model at the falling limb of hydrographs. 6.Relative errors in the q/qp at the point of 0.8 and 1.2 for the dimensionles ratio by linear model and S. C. S. method showed to be 2.41, 1.57 and 4.0, 3.19 percent respectively to the q/qp of observed dimensionless unit hydrographs. 7.Derivation of dimensionless unit hydrograph by linear model can be accomplished by linking the two empirical formulars for storage constant, K, and shape parameter, n with derivation formular for dimensionless unit hydrograph for the ungaged small watersheds.

  • PDF

FINITE ELEMENT STRESS ANALYSIS OF A TOOTH RESTORED WITH CAD/CAM CERAMIC INLAY (CAD/CAM 세라믹 인레이로 수복한 치아의 응력분포에 관한 유한요소법적 연구)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.464-484
    • /
    • 2001
  • When restoring a tooth, the dentist tries to choose the ideal material for existing situation. One criterion that is considered is its suitability for restoring coronal strength. As more tooth structure is removed, the cusps are weakened and susceptible to fracture. Further, this increased deformation may cause the formation of intermittent gaps at the margin between the hard tissue and the restoration, facilitating marginal leakage. The improvements in ceramic materials now make it possible for alternatives to amalgams, composites, and cast metal to be of offered for posterior teeth. Of the materials used, ceramics most closely approximates the properties of enamel. The introduction of computer-aided design/computer-aided manufacture(CAD/CAM) systems to restorative dentistry represents a major technological breakthrough. It is possible to design and fabricate ceramic restorations at a single appointment. Additionally, CAD/CAM systems eliminate certain errors and inaccuracies that are inherent to the indirect method and provide an esthetic restoration. The aim of this investigation was to study the loading characteristics of CAD/CAM ceramic inlay and to compare the stress distribution and displacement associated with different designs of cavity(the isthmus width and cavity depth). A human maxillary left first premolar was prepared with standard mesio-occlusal cavity preparation, as recommended by the manufacturer Ceramic inlay was fabricated with CEREC 2 CAD/CIM equipment and cemented into the prepared cavity. Three dimensional model was made by the serial photographic method. The cavity width was varied $\frac{1}{3}$, $\frac{1}{2}$ and $\frac{2}{3}$ of intercuspal distance between buccal and lingual cusp tip. The cavity depth was varied 1.5mm and 2.3mm. So six models were constructed to simulate six conditions. A point load of 500N was applied vertically onto the first node of the lingual slope from the buccal cusp tip. The stress distribution and displacement were solved using ANSYS finite element program(Swanson Analysis System). (omitted)

  • PDF

An Improved AE Source Location by Wavelet Transform De-noising Technique (웨이블릿 변환 노이즈 제거에 의한 AE 위치표정)

  • Lee, Kyung-Joo;Kwon, Oh-Yang;Joo, Young-Chan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.490-500
    • /
    • 2000
  • A new technique for the source location of acoustic emission (AE) in plates whose thichness are close to or thinner than the wavelength has been studied by introducing wavelet transform de-noising technique. The detected AE signals were pre-processed using wavelet transform to be decomposed into the low-frequency, high-amplitude flexural components and the high-frequency, low-amplitude extensional components. If the wavelet transform de-noising was employed, we could successfully filter out the extensional wave component, one of the critical errors of source location in plates by arrival time difference method. The accuracy of source location appeared to be significantly improved and independent of the setting of gain and threshold, plate thickness, sensor-to-sensor distance, and the relative position of source to sensors. Since the method utilizes the flexural component of relatively high amplitude, it could be applied to very large, thin-walled structures in practice.

  • PDF