• 제목/요약/키워드: Distance Measurement Method

검색결과 940건 처리시간 0.032초

Unrestricted Measurement Method of Three-dimensional Walking Distance Utilizing Body Acceleration and Terrestrial Magnetism

  • Inooka, Hikaru;Kim, HiSik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.94.5-94
    • /
    • 2001
  • Unrestricted measurement method of three-dimensional walking distance utilizing body acceleration and terrestrial magnetism is discussed. The three-dimensional walking distance is derived by the integration of the three dimensional acceleration of foot during swing phase. Since the sensor system attached on the foot rotates during swing phase, the acceleration data measured on the foot include acceleration of gravity which causes inaccurate calculation of the velocity and the distance. Three gyros are used to compensate the rotation of the sensor system. Moreover, one geomagnetic sensor is employed to derive the heading direction of the subject Healthy volunteers performed ...

  • PDF

Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio (감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구)

  • Kim, Jun-Ha;Cheong, Jea-Hak;Hong, Sang-Bum;Seo, Bum-Kyung;Lee, Byung Chae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제18권1호
    • /
    • pp.51-62
    • /
    • 2020
  • This study was conducted to develop a method for depth assessment of embedded sources using gamma-spectrum ratio and for the evaluation of field applicability. To this end, Peak to Compton and Peak to valley ratio changes were evaluated according to 137Cs, 60Co, 152Eu point source depth using HPGe detector and MCNP simulation. The effects of measurement distance of PTV and PTC methods were evaluated. Using the results, the source depth assessment equation using the PTC and PTV methods was derived based on the detection distance of 50 cm. In addition, the sensitivity of detection distance changes was assessed when using PTV and PTC methods, and error increased by 3 to 4 cm when detection distance decreased by 20 cm based on 50 cm. However, it was confirmed that if the detection distance was increased to 100 cm, the effects of detection distance were small. And PTV and PTC methods were compared with the two distance measurement method which evaluates the depth of source by the change of net peak counting rate according to the detection distance. As a result of source depth assessment, the PTV and PTC showed a maximum error of 1.87 cm and the two distance measurement method showed maximum error of 2.69 cm. The results of the experiment confirmed that the accuracy of the PTV and PTC methods was higher than two distance measurement. In addition, Sensitivity evaluation by horizontal position error of source has maximum error of less than 25.59 cm for the two distance measurement method. On the other hand, PTV and PTC method showed high accuracy with maximum error of less than 8.04 cm. In addition, the PTC method has lowest standard deviation for the same time measurement, which is expected to enable rapid measurement.

A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position (줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Ha, Sung-Min
    • Physical Therapy Korea
    • /
    • 제20권3호
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

Nerve length measurement method in a radial motor nerve conduction study

  • Kim, Jae-Gyum;Kim, Yoohwan;Seok, Hung Youl;Kim, Byung-Jo
    • Annals of Clinical Neurophysiology
    • /
    • 제19권1호
    • /
    • pp.28-33
    • /
    • 2017
  • Background: Previous studies of radial nerve conduction study (NCS) did not present how to measure the length of the radial nerve across the elbow, and did not even mention how to manage the spiral course of the nerve. This study aimed to applicate the most reliable method to measure the length of the radial nerve during NCS. Methods: Three points (A, B, and C) were determined along the relatively straight course of the radial nerve. The distance was measured using three different methods: L1) straight distance corresponding to the A-C distance, L2) sum of the distances corresponding to the A-B-C distance, L3) based on the L2, but the elbow is flexed at a $45^{\circ}$ angle. We compared the three methods of distance measurement and the calculated nerve conduction velocities (V1, V2, and V3) in normal healthy subjects. Results: 19 normal participants were enrolled. The mean value for method L1, L2 and L3 were $22.5{\pm}1.8cm$, $24.0{\pm}2.1cm$, and $23.2{\pm}2.1cm$ (p < 0.001). Calculated conduction velocities using those distance measurement methods as follows (p < 0.001): V1 ($60.9{\pm}2.7m/s$), V2 ($64.6{\pm}3.3m/s$), and V3 ($63.4{\pm}3.9m/s$). V2 was significantly greater than V1 and V3 (p < 0.001, p = 0.010, respectively). Conclusions: The distance measurement using a stopover point near the lateral epicondyle between two stimulus points in position of a fully extended elbow with forearm pronation is the most appropriate posture for radial motor NCS.

Evaluation Method for Communication Distance Measurement Method for Mobility Characteristics of Service Robot in Wi-Fi Network Based (Wi-Fi 네트워크 기반에서 서비스 로봇의 이동특성을 위한 통신거리 성능평가 방법)

  • Min, Sun-Ho;Seo, Chang-Ho;Hong, Do-Won
    • Journal of Digital Convergence
    • /
    • 제10권3호
    • /
    • pp.265-271
    • /
    • 2012
  • This paper proposes a communication distance performance evaluation method for mobility of service robots equipped with a Wi-Fi module. Service robots have function of mobile communication system according to classified services and utilize a (preferred) communication method, wireless lan(IEEE802.11 a/b/gin) communication method of ISM band(2.4GHz and 5.8GHz). For evaluating degradation performance of wireless data for the service robot's mobility. We measured and presented reference vectors obtained by utilizing a distance attenuation correlation method in the real world environment. To evaluate performance of the proposed method, path loss of reference vectors was assigned to the Azimuth 301W and then transmission rate and the transmit throughput of the test sample were measured by the Chariot. The proposed measurement method is necessary for securing wireless LAN communication distance for mobility of mobile smart device and service robots. In addition, if the proposed measurement method os adopted, It would be expected that mobile smart device vendors would utilize the method as an effective wireless LAN mobility communication distance performance evaluation method.

An Improved Phase Estimation Method for AM Range Measurement System (진폭 변조 거리 측정 시스템에 적용 가능한 개선된 위상 추정 기법)

  • Kim, Dae-Joong;Oh, Taek-Hwan;Hwang, Sun-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제37권6C호
    • /
    • pp.453-461
    • /
    • 2012
  • This paper proposes an improved phase estimation method for AM(Amplitude Modulation) range measurement system. The previous phase estimation method induces errors by Doppler shift of a moving target. The proposed method compensates phase estimation error through the ADC(Adaptive Doppler Correction) to take the Doppler shift, thus can improve distance measurement accuracy. When compared with the previous method through simulation results, the Doppler shift compensation and accuracy are improved by 94.7% and 50%, respectively. Target distance error in an acoustic tank is estimated to be 7.7cm, which confirms that the proposed method can be used to estimate the distance in the marine environment.

Distance Measurement Using a Single Camera with a Rotating Mirror

  • Kim Hyongsuk;Lin Chun-Shin;Song Jaehong;Chae Heesung
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.542-551
    • /
    • 2005
  • A new distance measurement method with the use of a single camera and a rotating mirror is presented. A camera in front of a rotating mirror acquires a sequence of reflected images, from which distance information is extracted. The distance measurement is based on the idea that the corresponding pixel of an object point at a longer distance moves at a higher speed in a sequence of images in this type of system setting. Distance measurement based on such pixel movement is investigated. Like many other image-based techniques, this presented technique requires matching corresponding points in two images. To alleviate such difficulty, two kinds of techniques of image tracking through the sequence of images and the utilization of multiple sets of image frames are described. Precision improvement is possible and is one attractive merit. The presented approach with a rotating mirror is especially suitable for such multiple measurements. The imprecision caused by the physical limit could be improved through making several measurements and taking an average. In this paper, mathematics necessary for implementing the technique is derived and presented. Also, the error sensitivities of related parameters are analyzed. Experimental results using the real camera-mirror setup are reported.

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

Distance measurement technique using a mobile camera for object recognition (객체 인식을 위한 이동형 카메라를 이용한 거리 측정 기법)

  • Hwang, Chi-gon;Lee, Hae-Jun;Yoon, Chang-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.352-354
    • /
    • 2022
  • Position measurement using a camera has been studied for a long time. This is being studied for distance recognition or object recognition in autonomous vehicles, and it is being studied in the field of indoor navigation, which is a limited space where GPS is difficult to apply. In general, in a method of measuring the distance using a camera, the distance is measured using a distance between the cameras using two stereo cameras and a value measured through a captured image or photo. In this paper, we propose a method of measuring the distance of an object using a single camera. The proposed method measures the distance by using the distance between cameras, such as a stereo camera, and the value measured by the photographed picture through the gap of the photographing time and the distance between photographing.

  • PDF

A Study on the Improvement of Accuracy of Shape Measurement in the Shadow Moire Method (그림자식 모아레를 이용한 형상측정법의 정확도 개선에 관한 연구)

  • 박경근;박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 한국공작기계학회 1999년도 춘계학술대회 논문집
    • /
    • pp.175-180
    • /
    • 1999
  • Generally, When we measure of object 3D surfaces with phase shifting shadow moire method, it is use of optical system consist of light source, grating, and ccd camera. At this time, it is important parameter that vertical distance of grating and camera, grating and light source, and horizontal distance of camera and light source. When use camera consist of complex lens vertical distance of grating and camera is unknown parameter. From this cause equivalent wave length of moire fringe is uncertain. In this study, We exactly obtain a vertical distance of grating and camera so improve on measurement accuracy.

  • PDF