• Title/Summary/Keyword: Distance Information

Search Result 6,862, Processing Time 0.034 seconds

Characterization of Heavy Metals in the Stream Sediment around an Old Zinc Mine (가학광산 지역 하천 저니토 중금속의 화학적 특성)

  • Yoo, Sun-Ho;Ro, Kwang-Jun;Lee, Sang-Mo;Park, Moo-Eon;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.432-438
    • /
    • 1996
  • This study was carried out to prepare information for the establishment of countermeasures for an area contaminated with minewaste from an old zinc mine at Kahak-long in Kwangmyong. Minewaste and bottom sediments from the streams in this area were sampled and were analyzed for Cd, Cu, Pb, and Zn extracted with different solution. Total heavy metal contents in both minewaste and bottom sediments were fairly high. Cadmium and Zn contents in the minewaste and Cd, Cu, Pb, and Zn contents in the bottom sediments extracted with 0.1 N HCl showed a much higher level than those in the background level of paddy soils and in the soils around the other metal mines regardless of the distance from the mine. Sulfide/residue forms of Cd, Cu, Pb, and Zn covered the highest portions for the minewaste. For bottom sediments, sulfide/residue forms of Cu and Zn formed the highest portions, whereas the contents of both carbonate and sulfide/residue forms of Cd and Pb were significant. The lower the pH of the extracting solutions, the more heavy metals extracted from both minewaste and bottom sediments.

  • PDF

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Taxonomic Characteristics of Korean-native Anacardiaceae (한국산(韓國産) 옻나무과(科)의 분류학적(分類學的) 연구(硏究))

  • Kim, Sam Sik;Chung, Jae Min
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.2
    • /
    • pp.151-165
    • /
    • 1995
  • This study was conducted to establish a systematized taxonomic problems of through the leaf morphological characters and leaf venation patterns, and stomatal cell patterns and cell characteristics of abaxial and adaxial surface of the leaflets by SEM, of 6 native species in Korea and 2 foreign species of the Genus Rhus in the Family Anacardiaceae. The results obtained from this study are summarized as followings: 1. Morphological study measured 32 characters of leaves from herbarium specimen and field-collected samples for each species. The results of cluster analysis based on the Euclidean distance showed that the species could be classified into 3 groups: R. sylvestris. R. typhina, R. succedanea: R. trichocarpa. R. chinensis. R. verniciflua: and R. ambigua. R. radicans subsp. orientale, Analysis of principal components showed 5 groups: The major factors in the first principal component group was length of petiole of the terminal leaflets, that in the second group angle of left side in the terminal leaflet bash, that in the third group area ratio between first and terminal leaflets, that in the forth group angle ratio between right and left side in the terminal leaflet base, and that in the fifth group was angle of main and secondary vein at midrib of terminal leaflet. Cumulative contribution by the first, second and third principal component group was explained with 82.6%, a large percent of all information. 2. The leaf venation pattern investigated using soft X-ray photography revealed clado-and reticulo-camptodromous types according to branching angle of the secondary vein. And three groups by the developing degree of secondary vein were R. trichocarpa, R. ambigua. R. chinensis, R. typhina; R. radicans subsp. onentale, R. succedanea, R. verniciflua: and R. sylvestris. Classification key for the Rhus of Korean-native Anacardiaceae was made by the venation pattern and devevoping degree of the secondary vein. 3. The stomatal cell patterns were greatly classified into paracytic and anomocytic types, specific among species according to stomatal and subsidiary cell patterns, and various differences among the species was determined. Microstructure of the adaxial and abaxial surfaces could be divided into synclinal and anticlinal cell wall patterns, and were specific-species. Stomatal cells of R. chinensis were surrounded with characterized villus-like cells.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Health Medical Center Utilization Pattern and Its Related Factors among the Rural Inhabitants (농촌지역(農村地域) 주민(住民)들의 보건의료원(保健醫療院) 이용양상(利用樣相)과 관련요인(關聯要因))

  • Hwang, Byung-Deog;Park, Jae-Yong
    • Journal of agricultural medicine and community health
    • /
    • v.18 no.1
    • /
    • pp.77-91
    • /
    • 1993
  • This study was conducted to assess health medical center utilization pattern and its related factors among the rural inhabitants for the purpose of contribution to establishment of health medical center institutions. A questionnaire survey was carried out for object of 3,754 population of three primary school and three middle school student's parents (total 832 household) in Kyungbook Ulchin Gun rural area from 24 to 28 September, 1990. The summarized result are as follows, Respondents are 60.3% in male, 39.7% in female and 30-40s 81.3% in age, high school graduates 40.3% in education level and a regional medical insurance scheme in 44.1% in forms of health insurance. Recognition for health medical center was showed higher according to high educational, high income level, and short distance for location of health medical center of respondents (p < 0.01). Recognition for health medical center services was showed higher about care of medicaid in medical treatment services and higher preventive vaccination in health prevention services by respondents. Utilization rates of health medical center by out-patient care and preventive care service were 11.1 and 4.5 per 100 persons by year, but admission utilization rate was 34.6 per 10.000 persons by year. Motivations of health medical center utilization were showed a good care(45.7%), a good drugs(45.2%), and nearby health medical center(42.9%). In comparison health service levels of health medical center with general clinic was better (16.3%), similar(38.7%), 7(19.0%), and worse(19.0%) in view of health medical center utilizators. Inconvinience about health medical center utilized was the most higher longtime waiting, the next was limited utilization times. Transportation utilited were on foot(55%), by bus(35.5%), and so on. As mentioned above, there are many inhabitants who less understanding and less acknowledgement about health medical center and even mistake health center for health medical center. Therefore, there must be more information about health medical center. For higher utilization of health medical center, there must be considered expansion of health equipment, facilities, accomplishment with reinforcement of health staffs and efficiency management.

  • PDF

Implementation of a Self Controlled Mobile Robot with Intelligence to Recognize Obstacles (장애물 인식 지능을 갖춘 자율 이동로봇의 구현)

  • 류한성;최중경
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.312-321
    • /
    • 2003
  • In this paper, we implement robot which are ability to recognize obstacles and moving automatically to destination. we present two results in this paper; hardware implementation of image processing board and software implementation of visual feedback algorithm for a self-controlled robot. In the first part, the mobile robot depends on commands from a control board which is doing image processing part. We have studied the self controlled mobile robot system equipped with a CCD camera for a long time. This robot system consists of a image processing board implemented with DSPs, a stepping motor, a CCD camera. We will propose an algorithm in which commands are delivered for the robot to move in the planned path. The distance that the robot is supposed to move is calculated on the basis of the absolute coordinate and the coordinate of the target spot. And the image signal acquired by the CCD camera mounted on the robot is captured at every sampling time in order for the robot to automatically avoid the obstacle and finally to reach the destination. The image processing board consists of DSP (TMS320VC33), ADV611, SAA7111, ADV7l76A, CPLD(EPM7256ATC144), and SRAM memories. In the second part, the visual feedback control has two types of vision algorithms: obstacle avoidance and path planning. The first algorithm is cell, part of the image divided by blob analysis. We will do image preprocessing to improve the input image. This image preprocessing consists of filtering, edge detection, NOR converting, and threshold-ing. This major image processing includes labeling, segmentation, and pixel density calculation. In the second algorithm, after an image frame went through preprocessing (edge detection, converting, thresholding), the histogram is measured vertically (the y-axis direction). Then, the binary histogram of the image shows waveforms with only black and white variations. Here we use the fact that since obstacles appear as sectional diagrams as if they were walls, there is no variation in the histogram. The intensities of the line histogram are measured as vertically at intervals of 20 pixels. So, we can find uniform and nonuniform regions of the waveforms and define the period of uniform waveforms as an obstacle region. We can see that the algorithm is very useful for the robot to move avoiding obstacles.

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.

Evaluation of Germplasm and Development of SSR Markers for Marker-assisted Backcross in Tomato (분자마커 이용 여교잡 육종을 위한 토마토 유전자원 평가 및 SSR 마커 개발)

  • Hwang, Ji-Hyun;Kim, Hyuk-Jun;Chae, Young;Choi, Hak-Soon;Kim, Myung-Kwon;Park, Young-Hoon
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.557-567
    • /
    • 2012
  • This study was conducted to achieve basal information for the development of tomato cultivars with disease resistances through marker-assisted backcross (MAB). Ten inbred lines with TYLCV, late blight, bacterial wilt, or powdery mildew resistance and four adapted inbred lines with superior horticultural traits were collected, which can be useful as the donor parents and recurrent parents in MAB, respectively. Inbred lines collected were evaluated by molecular markers and bioassay for confirming their disease resistances. To develop DNA markers for selecting recurrent parent genome (background selection) in MAB, a total of 108 simple sequence repeat (SSR) primer sets (nine per chromosome at average) were selected from the tomato reference genetic maps posted on SOL Genomics Network. Genetic similarity and relationships among the inbred lines were assessed using a total of 303 polymorphic SSR markers. Similarity coefficient ranged from 0.33 to 0.80; the highest similarity coefficient (0.80) was found between bacterial wilt-resistant donor lines '10BA333' and '10BA424', and the lowest (0.33) between a late blight resistant-wild species L3708 (S. pimpinelliforium L.) and '10BA424'. UPGMA analysis grouped the inbred lines into three clusters based on the similarity coefficient 0.58. Most of the donor lines of the same resistance were closely related, indicating the possibility that these lines were developed using a common resistance source. Parent combinations (donor parent ${\times}$ recurrent parent) showing appropriate levels of genetic distance and SSR marker polymorphism for MAB were selected based on the dendrogram. These combinations included 'TYR1' ${\times}$ 'RPL1' for TYLCV, '10BA333' or '10BA424' ${\times}$ 'RPL2' for bacterial wilt, and 'KNU12' ${\times}$ 'AV107-4' or 'RPL2' for powdery mildew. For late blight, the wild species resistant line 'L3708' was distantly related to all recurrent parental lines, and a suitable parent combination for MAB was 'L3708' ${\times}$ 'AV107-4', which showed a similarity coefficient of 0.41 and 45 polymorphic SSR markers.

Characteristics of Fish Assemblage by Reservoir Size in Yeongsan·Seomjin River Watershed in Korea (영산강·섬진강 수계 호소의 규모별 어류군집 특성)

  • Park, Sang-Hyeon;Kim, Jeong-Hui;Baek, Seung-Ho;Choi, Ho-Seung;Kim, Dae-Won;Ko, Eui-Jeong;Kim, Hyun-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.53 no.3
    • /
    • pp.229-240
    • /
    • 2020
  • In this study, the results of fish assemblage survey for 16 reservoirs in the Yeongsan·Seomjin-River watershed were presented with fish assemblage characteristics analysis in relation to reservoir size. The survey method including number of sampling sites was followed the "Biomonitoring survey and assessment manual" of the Ministry of Environment/National Institute of Environmental Research (MOE/NIER), and the reservoirs were categorized as three size groups, small, medium or large reservoirs, based on the MOE/NIER as well. Total 13 family classified into 44 species were collected from 2018 (7 reservoirs) to 2019 (9 reservoirs), and the dominant and subdominant species were Hemiculter eigenmanni (Relative abundance, RA, 32.9%) and Lepomis macrochirus (RA, 31.4%), respectively. As a result of the analysis in relation to the reservoir size, the average (±standard deviation) number of species of the small, medium and large reservoirs were 11±2.9, 14.3±2.1, 22.7±0.6, respectively, which showed positive correlation with the reservoir size. Total 6 fish assemblage characteristics(number of species, number of individuals, richness index, herbivorous fish ratio, carnivorous fish ratio, exotic fish ratio) showed significant differences between the each reservoir size groups (P<0.05). As a result of cluster analysis, 16 reservoirs were clustered into 5 groups with 60% similarity, and the each reservoirs seems to be clustered depends on the distance from each other, watershed and their historical geology rather than size. These results are baseline information for the understanding of fish assemblage in Korean reservoirs, important for establishing management policy of reservoirs in the Yeongsan·Seomjin-River watershed.

2DEG Transport Analysis in AlGaAs/GaAs Interface by MONTE-CARLO Method (MONTE-CARLO 방법에 의한 AlGaAs/GaAs 계면의 전자 전달특성 분석)

  • Nam, Seung-Hun;Jung, Hak-Ki;Kim, Bong-Ryul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.94-101
    • /
    • 1989
  • Transport properties of 2DEG at AlGaAs/GaAs interface such as average electron energy, flight distance, each valley occupancy ratio, average electron velocity for various fields are investigated by MONTE-CARLO method. As the electric field increases, more electrons transit drastically from (000) valley to (000) upper valley. This phenomenon shows the nonstationary effect such as velocity overshoot. The duration of the transient decreases from about 1.4 psec for electric field E = 7KV/cm to about 0.7 psec for 12KV/cm. The average electron velocity during transient transport in 2DEG is about 8 times the steady-state velocity for E = 12KV/cm at room temperature. In comparison with bulk GaAs the peak velocity in the 2DEG is higher than that in even pure bulk GaAs at electric field E = 7 KV/cm. On the basis of the fact that the electrons in the 2DEG have larger peak velocity and shorter transient time of velocity than those in the bulk GaAs, it is suggested that the device with 2DEG may obtain higher mobility than that with bulk GaAs.

  • PDF