• Title/Summary/Keyword: Distal clavicle

Search Result 66, Processing Time 0.021 seconds

Clinical and Radiological Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocations and Distal Clavicle Fractures

  • Oh, Joo Han;Min, Seunggi;Jung, Jae Wook;Kim, Hee-June;Kim, Jae Yoon;Chung, Seok Won;Kim, Joon Yub;Yoon, Jong Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.2
    • /
    • pp.95-100
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the clinical outcomes and complications of hook plate fixation in acromioclavicular (AC) joint dislocations and distal clavicle fractures. Methods: We retrospectively reviewed a series of 60 consecutive patients with hook plate fixation for AC joint dislocation (group I) and distal clavicle fracture (group II). Groups I and II had 39 and 21 patients, respectively. Clinical results were evaluated using the pain visual analogue scale (VAS), simple shoulder test, and Constant-Murley scores. In addition, subacromial erosion and stiffness were evaluated as complications. Results: At the removal, the pain VAS was $2.69{\pm}1.30$ and $4.10{\pm}2.14$ in groups I and II, respectively, which were significantly different (p=0.003). The simple shoulder test score was $9.59{\pm}1.60$ and $7.81{\pm}2.67$ in groups I and II, respectively, which were also significantly different (p=0.002). Subacromial erosion was significantly more frequent in group II (14/21 patients, 66.7%) than in group I (15/39 patients, 38.5%) (p=0.037), and stiffness was also higher in group II (17/21 patients, 81.0%) than in group I (22/39 patients, 56.4%), but it was not significant. Conclusions: Hook plate fixation showed good clinical and functional results for the treatment of acute unstable AC joint dislocation and distal clavicle fracture. But, in distal clavicle fractures, there are more subacromial erosion and stiffness compare with acute unstable AC joint dislocation.

Operative Treatment of Distal Clavicle Fracture Nonunion (원위 쇄골 불유합의 수술적 치료)

  • Kang, Ho-Jung;Yoon, Hang-Seob;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.220-226
    • /
    • 2007
  • Purpose: The distal clavicle has a biomechanical structure different from that of the proximal or middle 1/3 clavicle, and delayed union or nonunion occurs frequently in a distal clavicle fracture. The authors obtained favorable results from an open reduction and bone grafting of the distal clavicle nonunion. We report the results together with review of the relevant literature. Materials and Methods: The subjects were 8 patients(average age, 38.9) who had undergone surgery for distal clavicle nonunion from August 2003 to May 2006. Nonunion occurred after surgical treatment in 4 cases, and after conservative treatment in the other 4. In all cases, the patients complained of pain. Results: The mean follow-up duration was 14 months, and radiological union was observed in 8 weeks on average. In all cases, the range of shoulder joint motion was normal at the end of the follow-up observation. In the functional evaluation, 7 cases showed excellent results and 1 case showed good results. Conclusion: Surgical treatment is a safe and reliable treatment for distal clavicle fracture nonunion because it can achieve early rehabilitation and union.

Distal Clavicle Tunnel Widening after Coracoclavicular Ligament Reconstruction with Semitendinous Tendon: A Case Report (반건양 건을 이용한 오구쇄골 인대 재건술후 발생한 원위부 쇄골 터널 확장: 증례 보고)

  • Yoo Jae-Chul;Kim Seung-Yun;Lim Tae-Gang;Jeong Ju-Seon;Song Baek-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.131-134
    • /
    • 2005
  • Distal clavicle tunnel widening was observed in coracoclavicular ligament reconstruction with semitendinous tendon autografts in a patient with acromioclavicular joint injury. Acromioclavicular joint separation, in a 44 years-old man was treated by coracoclavicular ligament reconstruction. We have performed x-ray evaluation on 2years 10months after surgery. The immediate postoperative tunnel size was measured 4.5mm in diameter. At postoperative 2years 10month the tunnel diameter was from 9.3 to 11.4mm. But the weightbearing clavicle view showed no significant acromioclavicular joint separation. Moreover the patient complained only minor intermittent shoulder discomfort.

Unusual and nondescript type of distal clavicular fracture

  • Fernandez, Alberto Izquierdo;Minarro, Jose Carlos
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.106-109
    • /
    • 2021
  • Displaced fracture of the distal third of the clavicle usually occurs after direct trauma to the shoulder and typically results in superior displacement of the proximal fragment. We report a previously undescribed case of downward displacement of the clavicle caused by a fall on an outstretched hand, and we suggest the mechanism of injury.

The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle (불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용)

  • Ko, Sang-Hun;Cho, Sung-Do;Park, Moon-Soo;Ryu, SuGoo
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.131-137
    • /
    • 2003
  • Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

Evaluation of the Acromioclavicular Joint Morphology for Minimizing Subacromial Erosion after Surgical Fixation of the Joint Using a Clavicular Hook Plate

  • Kim, Sung-Jae;Kee, Young-Moon;Park, Dong-Hyuck;Ko, Young-Il;Lee, Bong-Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.138-144
    • /
    • 2018
  • Background: Subacromial erosion remains a major concern after surgical fixation of acromioclavicular (AC) joint using a clavicular hook plate. To minimize postoperative subacromial erosion, we investigated the structural relationship between distal clavicle and acromion around the AC joint by considering the surgical fixation of the joint using the hook plate technique. Methods: Computed tomography scans of 101 AC joints without any inherent pathology were analyzed. The angle between the distal clavicle and acromion around the AC joint (AC angle), depth of the acromion, differences in height between distal clavicle and acromion (AC height difference), and thickness of distal clavicle and acromion at the AC joint were measured. Descriptive statistics were calculated for each anatomical parameter, and all results were compared between gender groups. Results: The mean AC angle was $17.1^{\circ}$(range, $-8.0^{\circ}$ to $39.0^{\circ}$), and the mean AC height difference was 3.5 mm (range, -0.7 to 8.7 mm). Both factors showed very high variability (coefficients of variation=62.6% and 46.6%, respectively). The mean AC angle was significantly higher in the female gender than in the male gender ($19.8^{\circ}$ vs. $13.8^{\circ}$, p=0.048). The mean acromion thickness and distal clavicular thickness were both significantly thinner in the female group than in the male group (p<0.001). Conclusions: Taken together, we believe our results might be helpful in minimizing postoperative subacromial erosion when performing surgical fixation of the AC joint using the hook plate, and be valuable in improving future design of the hook plate.

A modified method of augmented distal clavicle fracture osteosynthesis with a Fibertape coracoclavicular cerclage

  • Wu, ChengHan;Teo, Timothy Wei Wen;Wee, Andy Teck Huat;Toon, Dong Hao
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.230-235
    • /
    • 2022
  • Background: Unstable distal clavicles experience high non-union rates, prompting surgeons to recommend surgery for more predictable outcomes. There is a lack of consensus on the optimal method of surgical fixation, with an array of techniques described in the literature. We describe an alternative method of fixation involving the use of a distal clavicular anatomical locking plate with Fibertape cerclage augmentation in our series of patients. Methods: Nine patients (8 males and 1 female), with a mean age of 36 years, who sustained unstable fracture of the distal clavicle in our institution were treated with our described technique. Postoperative range of motion, functional and pain scores, and time to radiographic union were measured over a mean follow-up period of 10 months. Incidences of postoperative complications were also recorded. Results: At the last patient consult, the mean visual analog scale score was 0.88±0.35, with a mean Disabilities of the Arm, Shoulder, and Hand (DASH) score of 1.46±0.87 and American Shoulder and Elbow Surgeons (ASES) score of 94.1±3.57. The mean range of motion achieved was forward flexion at 173°±10.6°, abduction at 173°±10.6°, and external rotation at 74.4°±10.5°. All patients achieved internal rotation at a vertebral height of at least L2 with radiographical union at a mean of 10 weeks. No removal of implants was required. Conclusions: Our described technique of augmented fixation of the distal clavicle is effective, produces good clinical outcomes, and has minimal complications.

Osteochondroma of the Distal Clavicle: A Rare Cause of Impingement and Biceps Tear of the Shoulder

  • Kim, Dong-Wan;Bae, Ki-Cheor;Son, Eun-Seok;Baek, Chung-Sin;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.158-161
    • /
    • 2018
  • Hereditary multiple exostosis (HME) is an autosomal dominant disorder manifested by the presence of multiple osteochondromas. Although the lesions are benign in nature, exostoses are often associated with characteristic progressive skeletal deformity and displaying clinical symptoms such as mechanical irritation or impingement. We present the successful arthroscopic resection in a 24-year-old HME male with impingement syndrome and long head tendon tear of the biceps caused by osteochondroma arising from the distal clavicle.