• Title/Summary/Keyword: Dissipations Factor

Search Result 2, Processing Time 0.015 seconds

Electrical Properties and Temperature Effects of PET Films with Interface Layers

  • Dong-Shick kim;Lee, Kwan-Woo;Park, Dae-Hee;Lee, Jong-Bok;Seun Hwangbo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.4
    • /
    • pp.25-29
    • /
    • 2000
  • In this paper, PET(Ployethylene Terephthalate) films with semiconducting and interface layers were investigated, The electrical properties, such as volume resistivity, tan$\delta$(dissipation factor) and breakdown strength at various temperatures were measured. Thermal analysis of PET and semiconducting films were measured and compared by differential scanning calorimeter(DSC) of each film. It is found that the volume resistivity of films(dependence on semiconducting interface layers)and electrical properties of PET films are changed ,Breakdown strength and dissipation factor of PET films with semiconducting layer (PET/S/PET) are decreased more greatly than PET and PET/PET films, due to the increase of charge density of charges at two contacted interfaces between PET and semiconductor, The dissipation factor of each films in increased with temperature,. For PET/S/PET film, is depended on temperature more than PET of PET/PET. However, the breakdown strength is increased up to 85$\^{C}$ and then decreased over 100$\^{C}$The electrical properties of PET films with semiconducting/interface layer are worse than without it It is due to a result of temperature dependency, which deeply affects thermal resistance property of PET film more than semiconducting/interface layers.

  • PDF

Large Eddy Simulation of Turbulent Channel Flow Using Inhomogeneous Filter (비균질 필터를 사용한 난류 채널 유동의 Large Eddy Simulation)

  • Lee, Sang-Hwan;Kim, Kwang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1022-1031
    • /
    • 2004
  • The commutation errors by the filtering process in the large eddy simulation are considered. It is compared the conventional filter with the inhomogeneous filter that is devised to reduce the commutation errors. The weighting factor of the inhomogeneous filter suggested by Vasilyev is adopted. Also, using the optimizing function that estimates test filter width to eliminate the dissipations in the region excluding the vicinity of the wall, the flow patterns are analyzed. It is evaluated in simulations of the turbulent channel flow at Reynolds number of 1020, based on friction velocity and channel half height. Results show that the commutation errors can be significantly reduced by using the inhomogeneous filter and the optimized test filter width.