• Title/Summary/Keyword: Dissipation current

검색결과 448건 처리시간 0.026초

유입변압기 오일필터링에 따른 유전정접 변화사례 고찰 (Example study of the dissipation factor change according to the oil filtering in large oil-filled transformer)

  • 공태식;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2035_2036
    • /
    • 2009
  • This paper is purpose to understand the dissipation factor properties of the oil-filled large transformer according to the oil filtering. In order to know the insulation characteristic change by insulating oil filtering, we carried out the insulation diagnostic test for the same transformer before oil filtering and after. The insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, Especially we took notice of dissipation factor change, we analyzed and made a comparison of the two cases test result.

  • PDF

에너지 소산능력을 고려한 전단벽의 내진설계 (Seismic Design Method for Structural Walls Based on Energy Dissipation Capacity)

  • 박홍근;엄태성;정연희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.247-257
    • /
    • 2002
  • Recently, performance-based analysis/design methods such as the capacity spectrum method and the direct displacement-based design method were developed. In these methods, the estimation of energy dissipation capacity due to inelastic behavior of RC structures depends on empirical equations which are not sufficiently accurate. On the other hand, in a recent study, a simplified method for evaluating energy dissipation capacity was developed. In the present study, based on the evaluation method, a new seismic design method for flexure-dominated RC walls is developed. In determination of seismic earthquake load, the proposed design method can address variation of the energy dissipation capacity with design parameters such as dimensions and shapes of cross-sections, axial force, and reinforcement ratio and arrangement. The proposed design method is compared with the current performance-based design methods and the applicability of the proposed method is disscussed.

  • PDF

15 kVA급 저항형 초전도 한류기의 전류제한특성 (Characteristics of 15 kVA superconducting fault current limiter)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.272-275
    • /
    • 2000
  • We investigated a resistive superconducting fault current limiter (SFCL) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 Ap, was produced and successfully tested at a 220 V circuit. From the resistance increase, we estimated that the film temperature increases to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V.

  • PDF

광각 포물형 완경사 방정식에 관한 연구 (A Study of Wide-Angle Parabolic Mild Slope Equation)

  • 김재중;박정철
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.281-290
    • /
    • 1998
  • The propagation of water waves over irregular bottom bathymetry and around islands involves many process-shoaling, refraction, energy dissipation and diffraction. Numerical model in this study is developed with the mild slope equation to investigate wave transformation in water of varying depth and combined waves and a current. The method used is splitting method and minimax approximation. The numerical method used in this study is Crank-Nicolson scheme in the FDM. This model is applied to Vincent shoal and compared with laboratory experimental data. The results agreed well with laboratory data. Current effect is considered in this study. This model can be used for the estimation of rip current in the slowly varying topography.

  • PDF

이어도 종합해양과학기지에 대한 설계파력의 검토 II: 쇄파역에서의 유체력 (Investigation on the Design Wave Forces for Ear-do Ocean Research Station II: Fluid Force in the Breaking Wave Field)

  • 전인식;심재설;최성진
    • 한국해안해양공학회지
    • /
    • 제12권4호
    • /
    • pp.168-180
    • /
    • 2000
  • In the Part I, the three dimensional model testing with NNW deep water wave direction gave the results such that the occurrence of breaking waves over the peak of Ear-Do caused very small wave height at the structure position. But the measured wave forces were rather greater than the calculated forces based on deep water wave height. Furthermore, It was also perceived that the time series of the forces looked like corresponding to the case that waves were superimposed by an unidirectional current. In the present Part II, the current is presumed to be a flow secondly induced by breaking waves, and an extensive study to clarify the current in a quantitative sense is performed through numerical analysis and hydraulic experiment. The results showed that a strong circulation can surely occur in the vicinity of the structure due to radiation stress differentials given by the breaking waves. It was also recognized that the velocity of the induced current varied with the magnitude of energy dissipation rate introduced in the numerical analysis. The numerical analysis was tuned adjusting the dissipation rate so that the calculated wave field could closely match with the experimental results of Part I. The fluid force (in prototype) for the optimal match showed approximately 2.2% increased over the calculated value based on the deep water wave height (24.6m) whereas the force corresponding to the average of the experimental values showed the increase of about 13.0%.

  • PDF

완전-차동형 바이폴라 전류-제어 전류 증폭기(CCCA) (A fully-differential bipolar current-controlled current amplifier(CCCA))

  • 손창훈;임동빈;차형우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.289-292
    • /
    • 2001
  • A Novel fully-differential bipolar current-controlled current amplifier(CCCA) for electrically tunable circuit design at current-mode signal processing were designed. The CCCA was consisted of fully-differential subtracter and fully-differential current gain amplifier. The simulation result shows that the CCCA has current input impedance of 0.5 Ω and a good linearity. The CCCA has 3-dB cutoff frequency of 20 MHz for the range over bias current 100$mutextrm{A}$ to 20 ㎃. The power dissipation is 3 mW.

  • PDF

고압전동기 고정자 권선의 온도변화에 따른 절연특성 분석 (Analysis of the Temperature Influence on Insulation Characteristics in High Voltage Motor Stator Windings)

  • 공태식;주영호;김희동;박태성
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.786-790
    • /
    • 2012
  • A variety of diagnostic tests are widely applied in the field in industry to evaluate the condition of high voltage (HV) motor stator insulation. In this paper, the influence of temperature on the stator insulation diagnostic tests such as the insulation resistance, AC current, dissipation factor, and partial discharge measurements are studied and reported. The tests are performed with the HV motor stator winding temperature set between $40^{\circ}C$ to $80^{\circ}C$ in $10^{\circ}C$ intervals. It is shown that the AC current, dissipation factor, and partial discharge magnitude steadily increase with temperature, which suggests that temperature must be taken into account in the interpretation of the test results.

열경화성 분석을 위한 가속열화 된 Chlorosulfonated Polyethylene의 경년특성 연구 (Study of Thermal Ageing Behavior of the Accelerated Thermally Aged Chlorosulfonated Polyethylene for Thermosetting Analysis)

  • 신용덕
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.800-805
    • /
    • 2017
  • The accelerated thermal ageing of CSPE (chlorosulfonated polyethylene) was carried out for 16.82, 50.45, and 84.09 days at $110^{\circ}C$, equivalent to 20, 60, and 100 years of ageing at $50^{\circ}C$ in nuclear power plants, respectively. As the accelerated thermally aged years increase, the insulation resistance and resistivity of the CSPE decrease, and the capacitance, relative permittivity and dissipation factor of those increase at the measured frequency, respectively. As the accelerated thermally aged years and the measured frequency increase, the phase degree of response voltage vs excitation voltage of the CSPE increase but the phase degree of response current vs excitation voltage decrease, respectively. As the accelerated thermally aged years increase, the apparent density, glass transition temperature and the melting temperature of the CSPE increase but the percent elongation and % crystallinity decrease, respectively. The differential temperatures of those are $0.013-0.037^{\circ}C$ and, $0.034-0.061^{\circ}C$ after the AC and DC voltages are applied to CSPE-0y and CSPE-20y, respectively; the differential temperatures of those are $0.011-0.038^{\circ}C$ and $0.002-0.028^{\circ}C$ after the AC and DC voltages are applied to CSPE-60y and CSPE-100y, respectively. The variations in temperature for the AC voltage are higher than those for the DC voltage when an AC voltage is applied to CSPE. It is found that the dielectric loss owing to the dissipation factor($tan{\delta}$) is related to the electric dipole conduction current. It is ascertained that the ionic (electron or hole) leakage current is increased by the partial separation of the branch chain of CSPE polymer as a result of thermal stress due to accelerated thermal ageing.

완전차동 전류모드 준디지털 포스트필터를 사용하는 시그마-델타 DAC (A Sigma-delta DAC with a Fully-Differential Current-Mode Semidigital Postfilter)

  • 김재완;민병무김수원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.683-686
    • /
    • 1998
  • This paper introduces a sigma-delta DAC with a fully-differential current-mode semidigital IFIR postfilter. A proposed fully-differential postfilter exhibits not only an improved SNR(signal-to-noise ratio) but also a reduced opwer dissipation.

  • PDF

그래프 이론과 상관성을 이용한 PM OLED 다중선 구동 기술 (Multi-Line Driving Technology on PM OLED using Graph theory and Correlation)

  • 이길재;이창훈;정제창
    • 대한전자공학회논문지SP
    • /
    • 제47권1호
    • /
    • pp.62-72
    • /
    • 2010
  • PM OLED는 차세대 디스플레이의 하나로 많은 애플리케이션에 사용되고 있다. PM OLED를 애플리케이션에 적용하는데 있어 가장 큰 문제는 전력 소모와 제품 수명을 꼽을 수 있다. PM OLED 시장의 확대를 위해 이를 개선하기 위한 노력이 패널과 회로 측면에서 이루어지고 있다. 전력소모와 제품 수명은 상호 연관 관계가 있어, 회로 상에서 전력 소모를 줄이면 인가 전류가 감소하여 제품 수명이 향상된다. 그러므로 전력 소모를 회로적으로 보완하는 방법을 적용하여 구동 방식을 개선함으로 전력 소모 감소와 제품 수명 향상이 가능하다. 종래 Row-to-Row 방식을 개선하여 여러 Row를 동시에 구동하는 기술을 적용하면 전력 소모를 감소 시키고 수명을 연장할 수 있다. 본 논문은 여러 Row를 동시에 구동하는 방식을 적용함에 있어 Row 별 Column 데이터에 대해 확률적 개념을 도입하여 유사성이 높은 Row를 하나의 Group으로 분리하고 Group별로 차별적으로 Row 구동 방식을 적용하여 전력을 감소하여 패널 수명을 향상하였다.