• Title/Summary/Keyword: Disposable Cup

Search Result 17, Processing Time 0.026 seconds

Behavior-induced Disposable Cup Automatic Separation X-Bin Study

  • LEE, Su-Min;KIM, Seo-Hyun;KIM, Ye-Na;BYUN, Hyo-Jeong;KWON, Lee-Seung;JUNG, Min-Jae;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.1
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: This study seeks to develop behavior-induced automatic separation X-Bin for disposable cup speculators. Some students throw away the contents. Research design, data and methodology: Therefore, environmental beautification workers spend a lot of time sorting disposable cups at school garbage collection sites. Disposable cups that have been thrown away like this are bad in terms of appearance and smell. In addition, cleaning inside garbage affects recycling rates and is closely related to environmental problems. Results: Clean cleaning reduces the amount of garbage incinerated without being recycled and reduces the cost of recycling. According to Korean Social Trends 2020, COVID-19 began to spread, and recycling of disposable items such as disposable cups increased by about 15 percent from the same period last year. Conclusions: These are classified for recycling, and the amount of garbage thrown on the streets is estimated to be larger. In order to prevent COVID-19s, the use of disposable goods is inevitable, but facilities are needed to dispose of them properly.

Change in Risk of Dropout Due to Bleeding during Bloodletting-Cupping Therapy (습식 부항 시술시 사혈량에 따른 부항 탈락 위험도 탐색)

  • Kim, Daehyeok;Bae, Eunkyung;Park, Jeonghwan;Kim, Soyoung;Lee, Sanghun
    • Korean Journal of Acupuncture
    • /
    • v.35 no.1
    • /
    • pp.41-45
    • /
    • 2018
  • Objectives : To investigate minimum pressure by verifying changes in pressure due to bleeding amount during bloodletting-cupping therapy. Methods : (1) We compared adhesion performance of four different cupping cups of same size: two disposable cupping cups(A, B) and two reusable cupping cups(A, B) each were vacuumed three times and kept in place for 10 minutes. (2) We vacuumed two different sized disposable cupping cups(A), size.1(InnerDiameter 48.8 mm) and size.3(InnerDiameter 39.1 mm), twice each(-200 mmHg) on silicon plate. We injected water and air at regular intervals in cupping cups by using a syringe, and then measured change of pressure in cupping cups and pressure at the time of dropout. Results : (1) Pressure reduction was $4.75{\pm}2.78%$ on average in the order of 'Disposable[A]>reusable[B]>Disposable[B]>reusable[A]', so that pressure retention performance of disposable cups can't be regarded as inferior to that of reusable cups. (2) Pressure of disposable cupping B(size.1) decreased by an average of -40.08 mmHg per 5 ml of water. At -24.8 mmHg, when 22 ml of water has been injected, cup has come off. Pressure of disposable cupping B(size. 3) decreased by an average of -99.4 mmHg per 5 ml of water. At -48.6 mmHg, when 13 ml of water was injected, cupping came off. Conclusions : Considering reduction rate of pressure due to water injection, in case of bleeding more than 15 ml, size.3 cup always comes off, therefore it needs to be re-operated at least once. Meanwhile, size.1 cup does not always come off in the same condition, depending on the initial pressure and therefore, re-operation may be considered.

Eco-Friendly Behavior of the Disposable Cup Deposit System: Focusing on Shadow Work, Perceived Efficacy, Environmental Consciousness, and Eco-guilt (일회용 컵 보증금 제도의 친환경행동: 그림자노동, 지각된 효능감, 환경의식, 에코 죄책감을 중심으로)

  • Zheng Yizhe;Joon Koh
    • Journal of Information Technology Services
    • /
    • v.22 no.5
    • /
    • pp.31-49
    • /
    • 2023
  • Due to the outbreak of the COVID-19, self-service technology is widely used in Korea, and demand for disposable cups is increasing significantly. Waste and recycling of disposable cups have become a social concern for Koreans and Korea implemented the "Disposable Cup Deposit Systems" again in December 2022. Whether the emergence of this system can change the way people behave in environmental protection is a question to be examined in this study. Companies participating in the disposable cup deposit system are hoping that customers will actively recover cups through self-service in the process of collecting disposable cups. The government, along with businesses, transfers recovery work to customers through self-service technologies and schemes. Due to the increase in Shadow Work and the strengthening of consumer environmental protection consciousness, this paper focuses on how unmanned service types such as self-service technology can affect people's environmental protection behavior. An empirical analysis with 477 samples examined how the characteristics of shadow work, perceived efficacy, environmental awareness, and ecological guilt affect user's environmental protection behavior. Perceived efficacy that acts as a mediator and ecological guilt that plays as a moderator are investigated. Although there have been many studies on the effects of shadow work on customer behavioral intentions before, it has been very rare to study the effects of shadow work perceived by people on environmental behavioral intentions from an environmental protection perspective. This study shows that the higher the perceived efficacy of consumers, the more people prefer self-service technology and the stronger the environmental protection behavior. Also, consumers' ecological guilt significantly moderates the relationship between environmental consciousness and eco-friendly behavior. It is expected that companies and governments will be able to understand the impact of shadow work on consumers' environmental protection behavior and further promote environmental protection by appropriate policies and marketing strategies.

Differences in dental hygienists' infection control awareness and re-user rate of disposable dental care supplies (치과위생사의 일회용 치과진료용품 감염관리 인지도와 재사용자율의 차이)

  • Park, Bo-Young;Noh, Hie-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.5
    • /
    • pp.645-653
    • /
    • 2020
  • Objectives: The purpose of this study is to identify the difference between the awareness and reuser rate of infection control t for disposable dental care supplies (DDCS) according to general characteristics and infection management-related characteristics. Methods: A questionnaire was used for 277 dental hygienists to check the general characteristics, infection management-related characteristics, awareness of infection control disposable dental care products, syringe needle, prophylaxis cup, prophylaxis brush, plastic saliva ejector, orthodontic bracket, and gloves reuse rate. Results: The awareness of infection control for DDCS differed according to 'hospital type', 'average number of patients per day', 'presence or absence of infection control guidelines', and 'experience in infection management training in the last two years' (p<0.05). Reuser rates of disposable dental care products differed according to 'hospital type', 'average number of patients per day', 'presence or absence of infection control guidelines', and 'experience in infection management training in the last two years' (p<0.05). Conclusions: In order to manage infection of DDCS, the level of infection control system in the workplace is improved and support for related education is needed. In addition, guidelines and regulations on prohibition of reuse and classification criteria for various DDCS should be prepared.

Simple Traction Device for Inverted Nipple Correction (묻힌젖꼭지 교정 후 사용 가능한 간단한 젖꼭지 견인장치)

  • Lee, Hye Mi;Na, Young Cheon
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.789-791
    • /
    • 2006
  • Purpose: The inverted nipple presents many problems in both cosmetic and functional aspects. The histopathologic features of inverted nipple are that inverted nipple has less fibromuscular tissue than normal nipple, short lactiferous duct and dense fibrous tissue. Many papers have been reported for correction of the inverted nipple, however not many medical literatures has specifically described about traction method. Although traditional traction methods were using half of urine cup or lid of bottle, they were uncomfortable and incapable for wearing brassiere. Methods: We invented a simple and more natural method using a dome-shape plastic disposable lid of take-out cup. We applied new device for three patients after corrective surgery. Results: For long term follow up, all patients satisfied their postoperative status and they were comportable with the lids. Conclusion: This new method is very simple, comfortable, and effective method for traction. It also allows patients to wear the brassiere.

A Study on activation method of tumbler sharing service for improve the issue of disposable cup (커피 전문점 텀블러 공유 서비스 활성화 방안 연구)

  • Park, Ga-young;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.18 no.1
    • /
    • pp.265-270
    • /
    • 2020
  • The purpose of this study is to suggest ways to reduce plastic use, one of the main culprits of environmental pollution around the world. Recently, the use of disposable cups at a domestic cafe has not been effective due to growing the number of stores and cafe in various brands. Cafes recommend the use of tumblers as a solution to the problem, but actual there are not many users in cafe. I need to investigate the problems of tumbler use and individual opinions through the first phase is FGI (Focus Group Interview). In the second phase, I investigate similar services, which are currently implemented in domestic and overseas, as a case study. The results showed that although similar services are offered in domestic, the focus is on tumbler sharing, which is somewhat insufficient for convenience provided when using cafes. Through this study, I hope to provide convenience and voluntary environmental protection by proposing a plan to activate Tumbler sharing services for cafe and users.

Optical Detection of Red Blood Cell Aggregation in a Disposable Microfluidic Channel

  • Shin Sehyun;Jang Ju-Hee;Park Myung-Soo;Ku Yunhee;Suh Jang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.887-893
    • /
    • 2005
  • The aggregability of red blood cells (RBCs) was determined by laser backscattering light analysis in a microfluidic channel. Available techniques for RBC aggregation often adopt a rotational Couette-flow using a bob-and-cup system for disaggregating RBCs, which causes the system to be complex and expensive. A disposable microfluidic channel and vibration generating mechanism were used in the proposed new detection system for RBC aggregation. Prior to measurement, RBC aggregates in a blood sample were completely disaggregated by the application of vibration-induced shear. With the present apparatus, the aggregation indexes of RBCs can be measured easily with small quantities of a blood sample. The measurements with the present aggregometer were compared with those of LORCA and the results showed a strong correlation between them. The aggregability of the defibrinogenated blood RBCs is markedly lower than that of the normal RBCs. The noble feature of this design is the vibration-induced disaggregation mechanism, which can incorporate the disposable element that holds the blood sample.

Optical Detection of Red Blood Cell Aggregation under vibration (진동장에서의 적혈구 응집성을 측정하는 광학적 방법)

  • Jang, Ju-Hee;Park, Myung-Su;Ku, Yun-Hee;Shin, Se-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1510-1515
    • /
    • 2004
  • Aggregability of red blood cells (RBCs) was determined by a laser backscattering light analysis in a microfluidic channel. Available techniques for RBC aggregation often adopt a rotational Couette-flow using bob-and-cup system for disaggregating RBCs, which causes the system to be complex and expensive. A disposable microfluidic channel and vibration generating mechanism were used in the proposed new detection system for RBC aggregation. Prior to measurement, RBC aggregates in a blood sample were completely disaggregated by applying vibration-induced shear. With the present apparatus, the aggregation indexes of RBCs can be easily measured with small quantities of blood sample. The measurements with the present aggregometer were compared with those of LORCA and showed a strong correlation between them. The aggregability of the defibrinogenated blood RBCs is markedly lower than that of the normal RBCs. The noble feature of this design is the vibration-induced disaggregation mechanism, which enables to incorporate disposable element that holds the blood sample.

  • PDF

A behavioral approach to increase recycling behavior: An examinination of effect of environmental alteration and prompts (환경문제에서의 재활용 행동 증진을 위한 행동분석적 실험 연구 - 환경적 변화와 프롬트의 효과를 중심으로-)

  • 오세진;양병화;현보성;황혜연
    • Hwankyungkyoyuk
    • /
    • v.14 no.1
    • /
    • pp.19-31
    • /
    • 2001
  • This study examined the effect of environmental alteration and prompts on recycling behavior. An A-B-BC with a control condition design was employed. Subjects in this study were college students, professors, and employees at a university building. After a baseline phase, environmental alteration was I effect in the next phase and both environmental alteration and prompts were in effect in the final phase for the control condition. The environmental alteration consisted of providing four separation containers for the paper cups, cans recyclable paper, and the disposable on each floor in the building. The prompts consisted of providing the information about the importance of environmental preservation and how to separate the materials in the appropriate containers using an information board and pamphlets. The dependent variables were (1) the number of cans collected in can container, (2) the number of paper cups collected in cup container, (3) the rate of correct separation of cans, (4) the rate of correct separation of paper cups, and (5) the weight of disposable. The rates of correct separations of cans and paper cups were obtained by calculating the percentage of thenumber of recyclable cans and paper cups in the corresponding containers. The results indicated that environmental alteration had positive effects on all the dependent variables. Also, when the prompts were added to the environmental alteration, the incremental effect of the prompts was demonstrated. The implications and limitations of theses findings were discussed and the direction of future studies was also proposed.

  • PDF

Effect of Chronic Toxicity by Waste Microplastics (PET) on Daphnia magna (폐 미세플라스틱(PET)의 물벼룩 만성독성 연구)

  • Han, Bomi;Park, GeonU;Yoo, Seungwoo;Kim, Changhae;Jung, Jinho;Na, Joorim
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.4
    • /
    • pp.281-289
    • /
    • 2021
  • Commercially used disposable cups undergo fragmentation in the environment and become microplastics (MPs). These MPs can be ingested by aquatic organisms and cause a range of adverse effects. We assessed the acute and chronic toxicity of disposable cup-derived MP fragments in Daphnia magna. MP fragments were identified as a polyethylene terephthalate (PET) fragment with a size of 33.18 ± 7.76 ㎛. The presence of three additives including 1- Propanone. 1-phenyl-3-[2-(phenylmethoxy)phenyl]-, p-Xylene and ethylbenzene was analyzed from MP fragments. The 48 h acute toxicity revealed that 20 % of immobilization and mortality were found at the highest concentration of PET MP (200 mg L-1). The 21 d chronic toxicity revealed that PET MP fragments significantly (p < 0.05) more reduced survival rate (31 %), total offspring (52 %) in D. magna compared with control group. The developmental abnormality of offspring (3.5%) by PET MP fragments was significantly (p < 0.05) higher than control groups (0.3%). These results are possibly induced by gut blocking by ingestion of MP fragments and their longer retention time. These findings indicate that the fragmentation of disposable cups (PET polymers) into small-sized MP fragments pose a significant ecological risk to aquatic organisms. Further studies are required to elucidate the underlying toxicity mechanisms.