• 제목/요약/키워드: Displacement Limit

검색결과 361건 처리시간 0.025초

Shaking table tests of prestressed damping-isolation units using a spring and rubbers

  • Yang, Keun-Hyeok;Mun, Ju-Hyun;Im, Chae-Rim;Won, Eun-Bee
    • Earthquakes and Structures
    • /
    • 제23권4호
    • /
    • pp.373-384
    • /
    • 2022
  • To improve the seismic performance of suspended ceiling structures, various vibration-damping devices have been developed. However, the devices made of metals have a limit in that they cause large deformation and seriously damages the exterior of the suspended ceiling structure from the wall. As a results, their strengthening effect of the suspended ceiling structure was minimal. Thus, this study employed a spring and vibration-proof rubber effectively controlled vibrations without increasing horizontal seismic loads on the ceiling to enhance the seismic resistance of suspended ceiling structures. The objective of the study is to examine the dynamic properties of a seismic damping-isolation unit (SDI) with various details developed. The developed SDI was composed of a spring, embossed rubbers, and prestressed bolts, which were the main factors enhancing the damping effect. The shaking table tests were performed on eight SDI specimens produced with the number of layers of embossed rubber (ns), presence or absence of a spring, prestressed force magnitude introduced in bolts (fps), and mass weight (Wm) as the main parameters. To identify the enhancement effect of the SDI, the dynamic properties of the control specimen with a conventional hanger bolt were compared to those of the SDI specimens. The SDI specimens were effective in reducing the maximum acceleration (Ac max), acceleration amplification factor (αp), relative displacement (δR), and increasing the damping ratio (ξ) when compared to the control specimen. The Ac max, αp, and δR of the SDI specimens with two rubbers, spring, and fps of 0.1fby, where fby is the yielding strength of the screw bolt were 57.8%, 58.0%, and 61.9% lower than those of the conventional hanger bolt specimens, respectively, resulting in the highest ξ (=0.127). In addition, the αp of the SDI specimens was 50.8% lower than those specified in ASCE 7 and FEMA 356. Consequently, to accurately estimate the αp of the SDI specimens, a simple model was proposed based on the functions of fps, stiffness constant of the spring (K), Wm, and ns.

유전자 알고리즘 및 인공신경망 이론을 이용한 쏘일네일링 굴착벽체 시스템의 최적설계 (Optimum Design of Soil Nailing Excavation Wall System Using Genetic Algorithm and Neural Network Theory)

  • 김홍택;황정순;박성원;유한규
    • 한국지반공학회논문집
    • /
    • 제15권4호
    • /
    • pp.113-132
    • /
    • 1999
  • 국내에서는 근래에 들어, 다양한 지반조건 및 현장여건을 지닌 지하굴착 및 사면보강 등의 현장에 쏘일네일링 공법의 적용이 점차 확대되어 왔다. 또한 쏘일네일링 공법의 설계는 일반적으로, 한계평형적 해석방법에 의거해 보강토체의 활동에 대한 소요안전율을 만족하는 단면을 우선 결정한 다음, 수치해석 프로그램을 이용하여 이 단면 전면벽체에서 예상되는 최대변위를 추가로 확인하는 비교적 단순화된 과정을 통해 이루어져 왔다. 그러나 쏘일네일링 공법의 경우 관련 설계변수가 비교적 다양한 특징을 지니고 있으며, 따라서 이와 같은 설계변수들 사이의 상호 연관성을 고려하는 보다 합리적인 설계법 제시 차원의 노력이 지속적으로 요구되는 실정이다. 이외에도 원지반 흙의 비등방성, 채취시료의 교란 정도 및 측정상의 오차 등 설계에 적용되는 각종변수가 지니고 있는 불확실성 등을 감안할 때, 현재 시점에서는, 축적된 다양한 현장의 계측자료를 수집하여 관련 설계변수 사이의 상호 연관성을 체계적으로 분석하려는 노력과 더불어 신뢰성 있는 효율적인 기법을 이용하여 경제성이 강조되는 최적화 설계 차원의 노력도 요구되는 시점으로 판단된다. 이와 같은 목적의 일환으로, 본 연구에서는 유전자 알고리즘을 이용하여 쏘일네일링 굴착벽체 시스템의 시공비용 최소화를 위한 최적설계기법을 제시하였으며, 또한 제시된 최적설계기법의 전제조건중의 하나로 고려되는 숏크리트 전면벽체의 발생변위를 합리적으로 예측하기 위해 인공신경망 이론을 도입하였다. 다양한 비교.분석과 더불어, 최종적으로는 제시된 쏘일네일링 굴착벽체 시스템 최적화 기법의 적합성 여부를 종합적으로 확인하기 위해, 실제 시공이 이루어진 현장의 설계단면과 제시기법에 의거해 최적화된 설계단면을 서로 비교.분석하였다.칠음 정도의 정량화 작업을 연구한 것이다.M SDS와 117mM $SOFTANOL\circledR-90$의 Log $K_m$은 각각 2.95-3.76, 2.95-3.49의 값을 나타내었다. 또한 SDS와 $SOFTANOL\circledR-90$의 경우 Log $K_m과\; Log\; K_{ow}$는 선형적인 관계를 보였다. 계면활성제 용액에서 BTEX의 분배 개념은 지반내 포집되어 있는 소수성 유기 오염물의 제거를 통한 지반복원과 효율성 평가에 중요한 역할을 할 것이다.largely ignored since the introduction of western medical science, and was considered something used only by the aged or the uneducated. Moreover, Health concerned practices and customary traditional therapy have been discarded in the clinical medicine as "unscientific" or "unsystematic". As described above, it is true that Korean nursing has developed in the quantitative aspect only adhering to western nursing intervention. Now it is the time to stop to hold ourself and to look back our past. To find and develop the originality of Korean nursing to

  • PDF

원격탐사의 지하수 수자원 적용 사례 고찰 (Review of Remote Sensing Studies on Groundwater Resources)

  • 이정호
    • 대한원격탐사학회지
    • /
    • 제33권5_3호
    • /
    • pp.855-866
    • /
    • 2017
  • 본 논문에서는 지하수 수자원의 부존 및 대수층의 역학적 변화를 원격 탐사 방법으로 해석한 연구사례를 고찰하였다. 지질 분포, 지표수 및 지형 고도차, 식생 분포, 강수량과 증발산량의 변화를 측정하는 기법에는 항공 자력 탐사 분석에 의한 지질 선구조 해석, DEM, 엽면적지수, 정규 식생 지수 및 지표면 에너지 밸런스 계산 등이 있으며, 모두 원격 탐사로 수득된 자료에 기반하며, 광역적 차원에서의 지하수 수자원 부존 여부를 정성적으로 분석할 수 있다. 위성 센서 자료의 직접 이용을 통한 지하수 부존 및 동력학의 정량적 해석은 현재까지 GRACE와 InSAR가 가장 각광받는 탐사 방법임을 알 수 있었다. GRACE는 미소 중력장 변화를 지구 표면 및 내부 수체의 질량 변화로 전환할 수 있는 센서 보유 위성으로서, 센서 자료의 보정이 필요 없고, 지하수 부존 정량 분석을 위한 보조 자료를 모두 다른 위성 센서 자료에서 수득할 수 있으며, 자료처리 알고리즘의 지속적인 개선이 진행되고 있어서, 전세계적으로 수많은 연구가 수행되었다. 그러나, 위성센서의 검출 한계로 인해 협소한 지역에서의 지하수 질량 변화 정량이 부정확할 수 있고, 현장 조사 자료와 연동할 경우 과대 추정된 결과가 도출될 수 있다. InSAR는 특정 대수층에서 지표의 수직 변위가 지하수위와 비례한다는 원리를 이용, mm 단위의 지표 수직 변위를 측정하여 대수층 및 대수층 내 지하수의 물리적 특징을 정량화할 수 있다. 그러나, 지표의 토지 피복이 단순한 건조-반건조 기후 지역에 한정되어 적용되고 있으며, 지표면과의 긴밀도 값 손실이 우려되는 지역에서는 적용이 힘들다. 상기 두 위성을 이용하여 우리나라 지하수 수자원의 질량 변화 및 흐름 특징을 광역적으로 정량화하기 위해서는 우리나라의 지형 및 지질, 자연 조건에 알맞은 자료 전처리 알고리즘 개발 및 적용이 선행되어야 할 것이다.

Hoek-Brown 파괴기준에서 유도된 연속체암반의 전단강도를 적용한 깎기 암반사면 경사 결정 연구 (A Study on Decision of Cut Rock Slope Angle Applied Shear Strength of Continuum Rock Mass Induced from Hoek-Brown Failure Criterion)

  • 김형민;이벽규;우재경;허익;이준기;이수곤
    • 한국지반환경공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.13-21
    • /
    • 2019
  • 급경사($65^{\circ}{\sim}85^{\circ}$)로 자연환경에서 장기간 안정한 상태로 유지되고 있는 깎기 또는 자연 상태의 암반사면이 다수 존재한다. 설계 실무측면에서 이와 유사한 암반상태 및 지질구조로 이루어진 지반을 양호한 연속체 암반사면으로 정의하고 있으며, 이 암반사면의 경사 결정 과정 중에 설계 및 시공 초기 단계의 안정해석 절차 단계에서 연속체 암반의 지반특성 평가방법을 수립하는 것이 중요하게 될 것이다. 이 연구에서는 급경사로 설계 가능한 양호한 연속체 암반사면의 안정해석 과정에서 지반정수 적용에 필요한 강도정수를 Hoek-Brown 파괴기준을 활용하여 실무적으로 산정하는 방안을 제안하고 이와 함께 급경사 암반사면의 안정해석을 통해 설계 적용성을 평가하였다. 기존 강도정수 산정방법은 작은 구속응력 변화에도 H-B파괴 포락선에 상응하는 등가 M-C강도정수가 민감하게 변화하므로 설계에서 실무적으로 활용하기가 부적합하였다. 이 문제점을 보완하기 위해 등각분할법으로 등가 M-C강도정수를 산정하는 방안을 제시하였다. 등각분할법의 설계 적용성을 확인하기 위해 기존 실시설계 현장에서 조성된 깎기 사면의 경사 변화에 따른 안전율 및 변위 결과를 검토하였다. 안전율은 1:0.5 사면에서 Fs=16~59이고, 1:0.3 사면에서 Fs=12~52이며, 대부분 10~12%의 감소를 보인다. 변위는 1:0.5 사면에서 0.126~0.975mm이고, 1:0.3 사면에서 0.152~1.158mm이며, 10~15%의 증가를 나타낸다. 이는 정규 비례의 미미한 변화이며, 안정성 측면에서는 양호한 상태이다. 설계 실무측면에서, H-B파괴기준에서 유도된 등각분할법으로 산정한 강도정수를 연구대상 암반사면과 유사한 양호한 암반에 대해 범용적인 강도정수로 적용하여도 안정적이고 경제적인 결과를 도출할 수 있다는 것을 확인하였다. 암반사면에 영향을 미치는 단층이 분포하지 않는 지반에서는 한계평형해석(LEM)과 유한요소해석(FEM)으로 안정해석하는 절차도 실무적으로 무난한 것으로 검토되었다. 연구대상 사면을 양호한 상태의 암반조건으로 선정하여 연구를 수행하였으나 좀 더 다양한 암반조건(터널 포함)에 보편적으로 적용할 수 있는지에 대한 검증 작업은 추후 연구과제가 될 것이다.

진동대 시험을 이용한 중공블록 보강 기초의 내진성능분석 (Analysis on Seismic Resistance Capacity of Hollow Concrete Block Reinforced Foundation Ground by Using Shaking Table Test)

  • 신은철;이연정;양태철
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.85-93
    • /
    • 2021
  • 한반도의 70%는 산지로 구성되어 있으며, 서해와 남해의 수심은 상대적으로 얕은 편이다. 따라서, 공업단지, 주거단지, 항만 및 공항 부지를 위한 대규모 간척사업이 시행되고 있다. 매립지역의 일반적인 문제는 지반이 연약하여 지지력이 부족할 뿐만 아니라 상당한 침하가 발생된다는 것이다. 중공블록은 중·저층 아파트 또는 단층의 공장건물을 건설하기 위해 계획된 느슨한 연약기초 지반보강을 위해 사용된다. 최근 4.0~5.0의 강도를 가진 지진이 서쪽과 남동쪽 해안지역을 따라 발생하고 있다. Lee (2019)는 정적 지지력시험을 통해 얕은 기초보강 중공블록의 장점에 대하여 연구하였다. 이 연구에서 블록 내부에 쇄석으로 채움된 보강된 모래지반의 중공블록 동적거동은 진동대 1000 mm × 1000 mm 시험을 통해 연구하였다. 3가지 지진파인 Ofunato, Hachinohe, Artificial 지진파와 2가지 가속도(0.154g, 0.22g)를 진동대 시험에 적용하였다. 중공블록으로 보강된 지반 위의 구조물 수평변위는 LVDT를 사용하여 측정하였다. 중공블록에 의한 지반보강 효율을 평가하기 위하여 지반의 상대밀도를 45%, 65%, 85%로 각각 구성하였으며, 수평변위를 측정하고 한계수평변위 0.015h(건축물 내진등급기준, 2019)와 비교하였다. 중공블록으로 보강된 모래지반에 대한 진동대 시험 결과에 기반해서 벌집 모양의 중공블록은 블록내부에 쇄석 채움으로서 큰 구속력을 가지며, 중공블록의 내부 및 외부를 따라 발생하는 관입저항력으로 인한 큰 주면마찰력을 갖는 것으로 평가되었다. 이러한 모든 요소들은 진동대 시험 중에 수평변위를 상당이 줄이는 것으로 나타났다. 마지막으로, 중공블록 보강 지반은 지진파와 가속도에 상관없이 중·저층 건물의 얕은기초 보강공법으로 매우 우수함이 입증되었다.

고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계 (Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository)

  • 황현중;박창희;홍창호;김진섭;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.451-464
    • /
    • 2022
  • 고준위방사성폐기물 처분장은 심지층 처분시스템으로 사용후핵연료를 취급하는 특성상 고온, 방사선 및 지하수 등의 복합적인 환경조건에 노출되어 있다. 지속적인 노출에 의해 시간이 지남에 따라 구조물의 균열 및 열화가 발생할 수 있다. 한편 고준위방사성폐기물 처분장은 초장기 기대수명이 요구되며 이에 따른 장기적인 구조물 건전성 모니터링이 필수적이다. 구조물 건전성 모니터링에는 가속도계, 토압계, 변위계 등 다양한 센서들이 활용될 수 있으며, 이 중 일반적으로 피에조센서가 사용된다. 따라서 피에조센서의 내구성 평가를 바탕으로 고내구성 센서를 개발할 필요가 있다. 본 연구에서는 피에조센서의 내구성 평가 및 수명예측을 위한 가속수명시험을 설계하였다. 문헌연구를 바탕으로 단일 스트레스 인자에 대한 가속 스트레스 수준 수 및 각 수준 별 시료 수를 선정하였다. 또한 고준위방사성폐기물 처분장 환경조건에서 발생할 수 있는 피에조센서의 고장모드 및 고장메커니즘을 분석하였다. 온도 스트레스 인자에 대한 최대 가혹조건 탐색 실험을 두 가지 방법으로 제안하였으며 피에조센서의 신뢰도 높은 동작한계를 도출하였다. 이를 이용하여 가속수명시험의 합리적인 가속 스트레스 수준을 설정하였다. 본 연구에서 제시된 최대 가혹조건 탐색 실험방법은 경제적이며 실용적인 아이디어를 담고 있으며, 추후 피에조센서의 가속수명시험 설계에 널리 활용될 수 있을 것으로 판단된다.

연속체 암반비탈면의 강도정수 산정 연구 (A Study on Estimating Shear Strength of Continuum Rock Slope)

  • 김형민;이수곤;이벽규;우재경;허익;이준기
    • 한국지반공학회논문집
    • /
    • 제35권5호
    • /
    • pp.5-19
    • /
    • 2019
  • 암반으로 구성되어 있는 급경사($65^{\circ}{\sim}85^{\circ}$)비탈면이 장기간 안정한 상태로 유지되고 있는 자연현상을 고려할 때, 설계 및 초기 시공 단계에서 위와 유사한 지반 상태로 이루어진 깎기 암반비탈면에 대해 1:0.5(발파암 경사 기준)보다 급한 경사를 적용할 수 있을 것이다. 급경사로 설계 가능한 양호한 연속체 암반비탈면의 안정성을 검토하는 과정에서, 설계실무 측면에서 범용적인 암반강도정수 산정방법이 필요하게 되었다. Hoek 등(2002)이 수정 보완하여 발표한 Hoek-Brown 파괴기준과 GSI분류는 불연속구조의 영향을 충분히 고려한 암반특성화 시스템으로 평가되었으며, 응력변화에 따라 등가 Mohr-Coulomb 강도정수(등면적법)를 산출하는 방법을 제안하였다. 비탈면에서는 등가 M-C 강도정수가 최대구속응력(${{\sigma}^{\prime}}_{3max}$ 또는 수직응력)변화에 따라 민감하게 변화하므로 실무적으로 활용하기에 어려운 점이 있다. 이 연구에서는 양호한 연속체 암반비탈면에 대해 최대구속응력 범위이내에서 범용적으로 적용할 수 있는 강도정수산정방법(등각분할법)을 H-B 파괴기준을 응용하여 제안한다. 등각분할법 강도정수(A)의 타당성 및 적용성을 평가하기 위해, 연구대상 암반비탈면을 기존 실시설계 현장 인근에 있는 급경사 비탈면에서 암석종류별(화성암, 변성암, 퇴적암)로 선정하고, Hoek이 제시한 등가 M-C 강도정수(등면적법)들과 비교 분석하였다. 등면적법 및 등각분할법 등가 M-C 강도정수는 기본적인 자료인 기존 실시설계 현장의 실내 암석 삼축압축시험과 연구대상 암반비탈면의 불연속구조의 특성조사(Face Mapping)를 통해 RocLab 프로그램(H-B 파괴기준을 기본으로 전산화된 지반정수 산정 소프트웨어)을 활용하여 산정하였다. 산정된 등면적법 등가 M-C 강도정수는 상호 연동되어 점착력과 내부마찰각이 아주 크거나($45^{\circ}$ 이상) 작게 나타났다. 등각분할법 등가 M-C 강도정수는 등면적법 등가 M-C 강도정수의 중간 정도이며, 내부마찰각은 $30^{\circ}{\sim}42^{\circ}$의 범위를 보인다. 연구대상 암반비탈면의 등각분할법 강도정수(A)와 기존 실시 설계 현장에서 연구대상 암반비탈면과 유사한 암반상태(동일 등급 RMR)에 적용한 강도정수(B)와 비교 분석하고, 이 지반정수들로 적용한 비탈면 안정해석(한계평형해석과 유한요소해석) 결과를 통해 제안한 등각분할법의 적용성을 간접적으로 평가하였다. A와 B의 강도정수 차이는 10% 정도이다. 한계평형해석 결과(우기 기준), A적용 안전율(Fs)=14.08~58.22(평균 32.9), B적용 안전율(Fs)=18.39~60.04(평균 32.2)이며, 각 동일한 암석종류에 따라 상호 유사하게 나타났다. 유한요소 해석 결과, A적용 변위=0.13~0.65mm(평균 0.27mm), B적용 변위=0.14~1.07mm(평균 0.37mm)으로 매우 유사하다. H-B 파괴기준을 응용하여 등각분할법으로 산출한 지반 정수를 실무적인 전단강도로 적용할 수 있는 적용성 평가에서 유의미한 결과를 확인할 수 있었다.

양호한 연속체 암반사면의 예비 판정기준 설정 연구 (A Study on Setup for Preliminary Decision Criterion of Continuum Rock Mass Slope with Fair to Good Rating)

  • 김형민;이수곤;이벽규;우재경
    • 지질공학
    • /
    • 제29권2호
    • /
    • pp.85-97
    • /
    • 2019
  • 암반으로 구성되어 있는 급경사($65{\sim}80^{\circ}$) 암반사면들이 장기간 안정한 상태로 유지되고 있는 것을 관찰할 수 있다. 이와 유사한 지반상태로 이루어진 굴착 암반사면에서 불연속구조가 비탈면의 안정성에 유리한 방향으로 분포하고 있는 경우에는 발파암 경사기준인 1 : 0.5 ($63^{\circ}$)보다 급한 경사를 적용할 수 있을 것이다. 비탈면 설계기준의 경사 결정 과정에서 급경사로 적용할 수 있는 예비 암반조건이 정량적으로 설정되어 있으면 설계 실무측면에서 지침으로 활용할 수 있을 것이다. 이 연구에서는 상기 암반을 양호한 연속체 암반으로 정의하고, 양호한 연속체 암반조건에 대해 공학적인 준거를 제공할 목적으로 범용적인 RMR, SMR, GSI 분류를 활용하여 정량적인 설정기준 범위를 제안하고자 하였다. 연구방법으로는 다음과 같다. 암석종류별로 급경사 $65{\sim}80^{\circ}$)에서 안정한 비탈면을 연구 대상으로 선정하고, Face mapping 결과를 반영하여 RMR과 SMR 및 GSI 분류하였다. Hoek-Brown 파괴기준을 활용하여 산정된 강도정수를 현 상태의 암반사면 안정해석에 적용하여 나타난 결과를 검토하였다. 급경사로 안정하게 유지되는 지반조건으로서 예비기준의 타당성을 검증하기 위한 것이다. 상기 연구방법으로 분석 검토한 결과, 양호한 연속체 암반비탈면은 Basic RMR ${\geq}50$ (퇴적암에서는 45), GSI SMR ${\geq}45$로 설정할 수 있을 것으로 분석되었다. 한계평형 해석의 안전율은 Fs = 14.08~67.50 (평균 32.9)이고, 유한요소해석의 변위는 0.13~0.64 mm (평균 0.27 mm)이다. 이는 급경사($65{\sim}80^{\circ}$)로 오랜 기간 동안 안정하게 유지되고 있는 양호한 연속체 암반사면의 안정성을 정량적으로 표현하고 확인하는 결과로 볼 수 있다. 양호한 연속체 암반사면에 대한 암반기준 설정범위는 자료가 축적되면 좀 더 세부적인 설정기준을 확립할 수 있을 것이고 추후 연구과제이기도 하다. 1 : 0.1~0.3의 급경사에서도 안정할 경우에, 해외 설계기준 및 사례를 참고하여 급경사의 상한 기준을 1 : 0.3으로 설계하면 경제성과 친환경성을 확보하는 이점이 있게 된다. 또한 굴착기술과 식생기술 발달 및 다양한 친환경적 사면 설계기법으로 급경사에 따른 심리적 불안감과 급격한 지반이완을 극복할 수 있을 것이다.

어린이의 외상성 치아손상에 관한 연구 (A Study on the Traumatic Teeth Damage of Children)

  • 유수민;박호원
    • 치위생과학회지
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 2004
  • 현대사회에서는 생활환경의 변화와 교통사고의 증가에 의해 해마다 소아의 외상의 증가하고 있는데 구강조직에 대한 외상성 손상을 완전히 치단하는 데에는 한계가 있어 외상성 치아손상에 관한 실태를 조사 분석함으로써 외상처치와 예방에 필요한 기초자료를 제시하고자 강릉대학교 치과병원 소아치과에 2000년 10월 4일부터 2004년 2월 27일까지 외상을 주소로 내원한 113명의 환자를 대상으로 조사 분석한 결과 다음과 같은 결론을 얻었다. 1. 연구대상자의 성별에서는 2.05:1의 비율로 남자의 경우가 외상빈도가 더 높게 나타났다. 평균 연령은 남자 5.27세, 여자 5.27세로 차이가 없었고, 전체 연령중 2세에서 외상환자가 제일 많았다(21.2%) 2. 외상부위별 내원기간을 조사한 결과 유치는 당일(34.4%)에 내원한 경우가 가장 많았고, 영구치는 1일 후(38.8%)에 내원한 경우가 가장 많았다. 3. 외상부위별 치아손상의 원인을 분석한 결과 넘어진 경우가 유치 59.4%, 영구치 55.1%, 물체에 부딪친 경우 유치 26.6%, 영구치 26.5%로 나타나 대부분 넘어지거나 부딪쳐서 외상이 발생한 것으로 나타났다. 4. 성별에 따른 치아손상이 발생한 장소는 가정인 경우가 남자 42.1%, 여자 35.1%로 남녀모두 가정에서 외상이 가장 많이 발생하였다. 외상부위에 따른 치아손상 발생한 장소로는 유치는 가정(59.4%)에서 가장 많이 발생하였고, 영구치는 유치원 및 학교(28.6%)에서 가장 많이 발생하였다. 5. 외상부위에 따라 치아손상을 받은 치아의 수를 분석한 결과 유치는 2개(56.3%), 1개(31.3%), 3개와 4개 이상 각각(6.3%), 순으로 나타났으며, 영구치는 2개(46.9%), 1개(28.6%) 4개 이상(16.3%), 3개(8.2%) 순으로 영구치인 경우 4개 이상인 경우도 비교적 높게 나타났다. 6. 성별에 따른 치아손상이 발생한 부위로는 남자 유치 56.6%, 영구치 43.4%, 여자 유치 56.8%, 영구치 43.2%로 남녀 모두 유치에서 외상이 가장 많이 발생하였다. 7. 유치와 영구치의 치아손상부위는 상악 전치부가 거의 대부분을 차지하고, 유치(75%)와 영구치(63.8%) 모두 상악 중절치에서 외상율이 높게 나타났다. 8. 전체적인 외상성 치아손상에 따른 외상종류의 조사결과는 동요 30.2%, 치관파절 28.0%, 함입 14.7%, 진탕 8.9%, 완전 탈구 7.1%, 정출 2.2%, 변위 1.8% 순으로 나타났다. 유치와 영구치별로 외상성 치아손상의 종류를 분류하였을 때 유치는 동요(35.8%)가 가장 많이 나타났고, 파절에서 치관파절은 영구치(44.8%)에서 많이 발생하였다. 9. 외상부위에 따른 외상성 치아손상처치는 처치없이 경과관찰을 한 경우가 유치는 43.2%, 영구치 38.9%로 나타났으며, 치료한 경우 유치는 치수절제술(22.0%), 영구치는 임시적산부식레진수복(19.5%)을 가장 많이 사용하였다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF