Development of Simultaneous Analytical Method of Veterinary Antibiotics in Manure using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 퇴비 및 액비 중 항생제 동시 분석법 개발)

  • Chung, Hyung Suk;Lee, Young Jun;Lee, Han Sol;Rahman, Md. Musfiqur;Kabir, Md. Humayun;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.201-210
    • /
    • 2017
  • BACKGROUND: The current study was to monitor of 9 veterinary antibiotics (ceftiofur, clopidol, florfenicol, sulfamethazine, sulfamethoxazole, sulfathiazole, tetracycline, tiamulin, and tylosin) in manure using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive and negative electrospray ionization mode. METHODS AND RESULTS: Sample preparation was carried out using Mcllvaine buffer and citrate salts to adjust the pH of the sample followed by purification with dispersive solid phase extraction (d-SPE). Separation of analytes during LC-MS/MS analysis was conducted using an Eclipse Plus $C_{18}$ column and the mobile phase was in gradient mode with, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations of all tested antibiotics was good, with $R^2$ determination coefficients ${\geq}0.9920$. The limit of detection (LOD) and quantifications (LOQ) were $0.1-67.0{\mu}g/kg$ and $0.4-200.0{\mu}g/kg$, respectively. Analysis of 13 solid and liquid manure samples taken from the Republic of Korea revealed concentrations less than $0.7{\mu}g/kg$ for tiamulin, $1497.6{\mu}g/kg$ for sulfamethazine. CONCLUSION: To monitor 9 veterinary antibiotics from manure samples in 13 provincial areas throughout the Republic of Korea, an analytical method was developed. The developed method was fully validated and successfully applied for monitoring various veterinary antibiotics in manure samples.

Determination of Isomaltooligosaccharides in Yoghurts by Using HPLC-ELSD (HPLC-ELSD를 이용한 발효유 제품 중의 Isomaltooligosaccharides 분석법 개발)

  • Ko, Jinhyouk;Lee, Moon-Seok;Kwak, Byung-Man;Ahn, Jang-Hyuk;Park, Jong-Su;Kwon, Joong-Ho
    • Food Science of Animal Resources
    • /
    • v.33 no.3
    • /
    • pp.417-424
    • /
    • 2013
  • A rapid and simple analytical method for the determination of 9 isomaltooligosaccharides (IMO) species in yoghurts was developed using dispersive solid phase extraction (dSPE) clean-up technic and high performance liquid chromatography with evaporative light-scattering detector (HPLC-ELSD). In this study, 9 IMO were extracted from samples simply with chemical reagent using ISO22662 IDF198 method and additional dSPE clean-up. The optimum instrument conditions for the determination were used carbohydrate ES $5{\mu}$ column with gradient elution of water and acetonitrile and ELS detector. The linearity of this method was expressed as the correlation coefficient ($r^2$), the results of IMO 9 species were shown in 0.9999. LOD and LOQ were respectively 7.9-22.1 mg/kg, 25.9-72.8 mg/kg. The accuracy of intra- and inter-day measurements were in the range from $84.3{\pm}4.5$ to $104.9{\pm}6.5%$, and the preceision of the intra- and inter-day measurements were in the range from 0.8 to 7.7%. The recoveries were from $84.3{\pm}4.5$ to $104.9{\pm}6.5%$. The determination results of IMO 9 species for the 9 yoghurts circulated in the market were in the range from $0.317{\pm}0.007$ to $1.624{\pm}0.050$ g/100 g. The newly developed method is appropriate for the determination of IMO in yoghurts, is a rapid and simple method with excellent resolution in compared with previous method.

Application and Validation of an Optimal Analytical Method using QuEChERS for the determination of Tolpyralate in Agricultural Products (QuEChERS법을 활용한 농산물 중 제초제 Tolpyralate의 최적 분석법 선발 및 검증)

  • Lee, Han Sol;Park, Ji-Su;Lee, Su Jung;Shin, Hye-Sun;Kim, Ji-Young;Yun, Sang Soon;Jung, Yong-hyun;Oh, Jae-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.3
    • /
    • pp.246-252
    • /
    • 2020
  • BACKGROUND: Pesticides are broadly used to control weeds and pests, and the residues remaining in crops are managed in accordance with the MRLs (maximum residue limits). Therefore, an analytical method is required to quantify the residues, and we conducted a series of analyses to select and validate the quick and simple analytical method for tolpyralate in five agricultural products using QuEChERS (quick, easy, cheap, effective, rugged and safe) method and LC-MS/MS (liquid chromatography-tandem mass spectrometry). METHODS AND RESULTS: The agricultural samples were extracted with acetonitrile followed by addition of anhydrous magnesium sulfate, sodium chloride, disodium hydrogencitrate sesquihydrate and trisodium citrate dihydrate. After shaking and centrifugation, purification was performed with d-SPE (dispersive-solid phase extraction) sorbents. To validate the optimized method, its selectivity, linearity, LOD (limit of detection), LOQ (limit of quantitation), accuracy, repeatability, and reproducibility from the inter-laboratory analyses were considered. LOQ of the analytical method was 0.01 mg/kg at five agricultural products and the linearity of matrix-matched calibration were good at seven concentration levels, from 0.0025 to 0.25 mg/L (R2≥0.9980). Mean recoveries at three spiking levels (n=5) were in the range of 85.2~112.4% with associated relative standard deviation values less than 6.2%, and the coefficient of variation between the two laboratories was also below 13%. All optimized results were validated according to the criteria ranges requested in the Codex Alimentarius Commission (CAC) and Ministry of Food and Drug Safety (MFDS) guidelines. CONCLUSION: In conclusion, we suggest that the selected and validated method could serve as a basic data for detecting tolpyralate residue in imported and domestic agricultural products.

Development and Validation of a Simultaneous Analytical Method for the Detection of Mefentrifluconazole and Triticonazole Fungicide in Agricultural Crops (농산물 중 메펜트리플루코나졸 및 트리티코나졸 살균제의 동시 분석법 개발 및 검증)

  • Park, Ji-Su;Lee, Han Sol;Lee, Su Jung;Shin, Hye-Sun;Shim, Jae-Han;Yun, Sang Soon;Jung, Yong-hyun;Oh, Jae-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.2
    • /
    • pp.130-137
    • /
    • 2020
  • BACKGROUND: Mefentrifluconazole and triticonazole are the triazole fungicides. The maximum residue levels for agricultural products need to be set up. Therefore, development of the official analytical method for determination of mefentrifluconazole and triticonazole residues from agricultural crops was necessary due to safety management, and then a simultaneous analytical method was developed for the determination of mefentrifluconazole and triticonazole in agricultural crops. METHODS AND RESULTS: Samples were extracted using acetonitrile and purified using dispersive solid phase extraction, and then detected with liquid chromatograph-tandem mass spectrometry (LC-MS/MS). Matrix-matched calibration curves (0.0025-0.25 ㎍/mL) were linear into a sample extract with r2>0.99. For validation, the recovery test was carried out at three fortification levels (LOQ, 10 LOQ and 50 LOQ) from agricultural samples. The results for mefentrifluconazole and triticonazole ranged between 92.3 to 115.3% and 91.4 to 108.5%, respectively and RSD (relative standard deviation) values were also below 6.0%. Furthermore, inter-laboratory was conducted to validate the method. CONCLUSION: All values were corresponded with the criteria ranges requested by both the CODEX (CAC/GL 40-1993, 2003) and MFDS guidelines (2016). Therefore, the proposed method can be used as an official analytical method for determination of mefentrifluconazole and triticonazole (triazole fungicides) in the Republic of Korea.

Monitoring of Neonicotinoid Pesticide Residues in Paprika Using UPLC-MS/MS from Gyeongnam Region (UPLC-MS/MS를 이용한 경남지역 파프리카 중 neonicotinoid계 농약 잔류 모니터링)

  • Kim, Nam-Kuk;Lee, Seung-Hwa;Nam, Yu-Jeong;Moon, Kyung-Mi;Park, Min-Ho;Yun, Mun-Hee;Kim, Mi-Young;Jang, Hyun-Min;Shin, Bong-Shig
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Monitoring or follow-up surveying pesticide residues in agricultural commodities is the key to meet the international regulations and to enhance international competitiveness of Korean agricultural commodities. Six neonicotinoid insecticides, acctamiprid, clothianidin, dinotefuran, imidacloprid, thiacloprid, and thiamethoxam were monitored in 95 paprika samples collected from Gyeongnam area. Thc pesticide residues were extracted by EN 15662 buffer based on the QuEChERS method, clean-upped with dispersive solid-phase extraction method to remove interfering pigments, and analyzed using UPLC-MS/MS. The neonicotinoid pesticides were detected in 90.5% of the paprika samples. Two or more pesticides were detected in 82.3% of samples. Although detection frequencies were high, all samples complied with the maximum residue limits (MRLs) set by both the Korea Food and Drug Administration (KFDA) and Japanese Ministry of Health, Labour and Welfare.

Development of the Analytical Method for Diazepam in Fishery Products using Liquid and Gas Chromatography-tandem Mass Spectrometry (LC-MS/MS 및 GC-MS/MS를 활용한 수산물 중 디아제팜의 정량분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Kim, Joohye;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.110-117
    • /
    • 2018
  • The aim of this study was to develop an analytical method for the quantification of diazepam residues in fishery products, using liquid and gas chromatography-tandem mass spectrometry (LC-MS/MS and GC-MS/MS). The sample utilized in the study was extracted from the fish sample (crucian carp) using 0.1% formic acid in acetonitrile. For the utilization of the purification process, the dispersive solid phase extraction (dSPE) was used for LC-MS/MS, dSPE and SPE was used for GC-MS/MS, respectively. To be sure, the standard calibration curves showed a good linearity as the noted correlation coefficients, $r^2$ was > 0.99. The average recoveries for accuracy ranged in 99.8~124% for the samples which were fortified at three different levels (0.001, 0.002 and 0.010 mg/kg). The correlation coefficient for the precision effect was measured at a range of 4.01~11.8%. The limit of detection (LOD) for the diazepam analysis was 0.0004 mg/kg, and the limit of the quantification (LOQ) was 0.001 mg/kg. The proposed analytical method was characterized with a high accuracy and acceptable sensitivity to meet the established Codex Alimentarius Commission (CAC/GL71-2009) guideline requirements. We therefore established the optimal analysis method for the determination of diazepam in the fishery products using LC-MS/MS and GC-MS/MS. It would be applicable to analyze the diazepam residues in fishery products in further studies on this subject.

Development and Validation of an Analytical Method for Fenpropimorph in Agricultural Products Using QuEChERS and LC-MS/MS (QuEChERS법과 LC-MS/MS를 이용한 농산물 중 Fenpropimorph 시험법 개발 및 검증)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.115-123
    • /
    • 2019
  • An analytical method was developed for the determination of fenpropimorph, a morpholine fungicide, in hulled rice, potato, soybean, mandarin and green pepper using QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) sample preparation and LC-MS/MS (liquid chromatography-tandem mass spectrometry). The QuEChERS extraction was performed with acetonitrile followed by addition of anhydrous magnesium sulfate and sodium chloride. After centrifugation, d-SPE (dispersive solid phase extraction) cleanup was conducted using anhydrous magnesium sulfate, primary secondary amine sorbents and graphitized carbon black. The matrix-matched calibration curves were constructed using seven concentration levels, from 0.0025 to 0.25 mg/kg, and their correlation coefficient ($R^2$) of five agricultural products were higher than 0.9899. The limits of detection (LOD) and quantification (LOQ) were 0.001 and 0.0025 mg/kg, respectively, and the limits of quantification for the analytical method were 0.01 mg/kg. Average recoveries spiked at three levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n=5) and were in the range of 90.9~110.5% with associated relative standard deviation values less than 5.7%. As a result of the inter-laboratory validation, the average recoveries between the two laboratories were 88.6~101.4% and the coefficient of variation was also below 15%. All optimized results were satisfied the criteria ranges requested in the Codex guidelines and Food Safety Evaluation Department guidelines. This study could serve as a reference for safety management relative to fenpropimorph residues in imported and domestic agricultural products.

Multi-residue Pesticide Analysis in Cereal using Modified QuEChERS Samloe Preparation Method (곡물류 중 잔류농약 다성분 분석을 위한 개선된 QuEChERS 시료 정제법의 개발)

  • Yang, In-Cheol;Hong, Su-Myeong;Kwon, Hye-Young;Kim, Taek-Kyum;Kim, Doo-Ho
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.314-334
    • /
    • 2013
  • This study explored an efficient modified Quick, Easy, Cheap, Effective, Rugged and safe (QuEChERS) method combined with liquid chromatography-electrospray ionization with tandem mass spectrometric detection for the analysis of residues of 76 pesticides in brown rice, barley and corn including acidic sulfonylurea herbicides. Formic acid (1%) acid in acetonitrile and dispersive solid phase extractions used for extraction of pesticides and clean-up of the extract respectively. Two fortified spikes at 50 and 200 ng $g^{-1}$ levels were performed for recovery test. Mean recoveries of majority of pesticides at two spike levels ranged from 73.2 to 132.2, 80.9 to 136.8, 66.6 to 143.5 for brown rice, barley and corn respectively with standard error (CV) less than 10%. Good linearity of calibration curves were achieved with $R^2$ > 0.9907 within the observed concentration ranged. The modified method also provided satisfactory results for sulfonylurea herbicides. The method was applied to the determination of residues of target pesticides in real samples. A total of 26 pesticides in 36 out of 98 tasted samples were observed. The highest concentration was observed for tricyclazole at 1.17 mg $kg^{-1}$ in brown rice. This pesticide in two brown rice samples exceeded their MRLs regulated for rice in republic of Korea. Except tricyclazole none of the observed pesticides' concentration was higher than their MRLs. The results reveal that the method is effectively applicable to routine analysis of residues of target pesticides in brown rice, barley and corn.

Development and Validation of an Analytical Method for Quinoxyfen in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 살균제 Quinoxyfen의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.140-147
    • /
    • 2019
  • An analytical method was developed for the determination of quinoxyfen in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted with 1% acetic acid in acetonitrile and water was removed by liquid-liquid partitioning with $MgSO_4$ (anhydrous magnesium sulfate) and sodium acetate. Dispersive solid-phase extraction (d-SPE) cleanup was carried out using $MgSO_4$, PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed by using LC-MS/MS in positive mode with MRM (multiple reaction monitoring). The matrix-matched calibration curves were constructed using six levels ($0.001-0.25{\mu}g/mL$) and the coefficient of determination ($R^2$) was above 0.99. Recovery results at three concentrations (LOQ, 10 LOQ, and 50 LOQ, n=5) were in the range of 73.5-86.7% with RSDs (relative standard deviations) of less than 8.9%. For inter-laboratory validation, the average recovery was 77.2-95.4% and the CV (coefficient of variation) was below 14.5%. All results were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for quinoxyfen determination in agricultural commodities. This study could be useful for the safe management of quinoxyfen residues in agricultural products.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.